The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
A paper and plastic device for performing recombinase polymerase amplification of HIV DNA
Open accessAbstract
Despite the importance of early diagnosis and treatment of HIV, only a small fraction of HIV-exposed infants in low- and middle-income countries are tested for the disease. The gold standard for early infant diagnosis, DNA PCR, requires resources that are unavailable in poor settings, and no point-of-care HIV DNA test is currently available. We have developed a device constructed of layers of paper, glass fiber, and plastic that is capable of performing isothermal, enzymatic amplification of HIV DNA. The device is inexpensive, small, light-weight, and easy to assemble. The device stores lyophilized enzymes, facilitates mixing of reaction components, and supports recombinase polymerase amplification in five steps of operation. Using commercially available lateral flow strips as a detection method, we demonstrate the ability of our device to amplify 10 copies of HIV DNA to detectable levels in 15 min. Our results suggest that our device, which is designed to be used after DNA extraction from dried-blood spots, may serve in conjunction with lateral flow strips as part of a point-of-care HIV DNA test to be used in low resource settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
DNA Detection Using Recombination Proteins
Piepenburg, O., Williams, C. H., Stemple, D. L., & Armes, N. A. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040204 · Cited by 2,482
Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Early Antiretroviral Therapy and Mortality among HIV-Infected Infants
Violari, A., Cotton, M. F., Gibb, D. M., Babiker, A. G., Steyn, J., Madhi, S. A., Jean-Philippe, P., & McIntyre, J. A. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800971 · Cited by 1,418
Newell, M.-L., Coovadia, H., Cortina-Borja, M., Rollins, N., Gaillard, P., & Dabis, F. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17140-7 · Cited by 1,182
Miniaturized isothermal nucleic acid amplification, a review
Asiello, P. J., & Baeumner, A. J. (2011) · Lab on a Chip · doi:10.1039/c0lc00666a · Cited by 407
Controlled reagent transport in disposable 2D paper networks
Fu, E., Lutz, B., Kauffman, P., & Yager, P. (2010) · Lab on a Chip · doi:10.1039/b919614e · Cited by 363
Programmable diagnostic devices made from paper and tape
Martinez, A. W., Phillips, S. T., Nie, Z., Cheng, C.-M., Carrilho, E., Wiley, B. J., & Whitesides, G. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00021c · Cited by 360
Microfluidics without pumps: reinventing the T-sensor and H-filter in paper networks
Osborn, J. L., Lutz, B., Fu, E., Kauffman, P., Stevens, D. Y., & Yager, P. (2010) · Lab on a Chip · doi:10.1039/c004821f · Cited by 338
Yu, J., Ge, L., Huang, J., Wang, S., & Ge, S. (2011) · Lab on a Chip · doi:10.1039/c0lc00524j · Cited by 327
Transport in two-dimensional paper networks
Fu, E., Ramsey, S. A., Kauffman, P., Lutz, B., & Yager, P. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0643-y · Cited by 313
Sommer, G., Rossa, C., Chi, A. C., Neville, B. W., & Heise, T. (2011) · PLoS ONE · doi:10.1371/journal.pone.0025402 · Cited by 228
He, Y., Zhang, S., Zhang, X., Baloda, M., Gurung, A. S., Xu, H., Zhang, X., & Liu, G. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.079 · Cited by 220
Dried Blood Spots Improve Access to HIV Diagnosis and Care for Infants in Low-Resource Settings
Sherman, G. G., Stevens, G., Jones, S. A., Horsfield, P., & Stevens, W. S. (2005) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/01.qai.0000143604.71857.5d · Cited by 197
Ciaranello, A. L., Park, J.-E., Ramirez-Avila, L., Freedberg, K. A., Walensky, R. P., & Leroy, V. (2011) · BMC Medicine · doi:10.1186/1741-7015-9-59 · Cited by 182
Govindarajan, A. V., Ramachandran, S., Vigil, G. D., Yager, P., & Böhringer, K. F. (2012) · Lab Chip · doi:10.1039/c1lc20622b · Cited by 177
LaBarre, P., Hawkins, K. R., Gerlach, J., Wilmoth, J. L., Beddoe, A., Singleton, J., Boyle, D. S., & Weigl, B. H. (2011) · PLoS ONE · doi:10.1371/journal.pone.0019738 · Cited by 158
Quantification of Human Immunodeficiency Virus Type 1 Proviral Load by a TaqMan Real-Time PCR Assay
Désiré, N., Dehée, A., Schneider, V., Jacomet, C., Goujon, C. P., Girard, P., Rozenbaum, W., & Nicolas, J. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.4.1303-1310.2001 · Cited by 149
Integrated microfluidic tmRNA purification and real-time NASBA device for molecular diagnostics
Dimov, I. K., Garcia-Cordero, J. L., O’Grady, J., Poulsen, C., Viguier, C., Kent, L., Daly, P., Lincoln, B., Maher, M., O’Kennedy, R. J., et al. (2008) · Lab on a Chip · doi:10.1039/b812515e · Cited by 144
Quantitative biomarker assay with microfluidic paper-based analytical devices
Xu, L., Tian, J., & Shen, W. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3195-9 · Cited by 135
Braun, M., Kabue, M. M., McCollum, E. D., Ahmed, S., Kim, M., Aertker, L., Chirwa, M., Eliya, M., Mofolo, I., Hoffman, I., et al. (2011) · JAIDS Journal of Acquired Immune Deficiency Syndromes · doi:10.1097/qai.0b013e31820a7f2f · Cited by 91
Jangam, S. R., Yamada, D. H., McFall, S. M., & Kelso, D. M. (2009) · Journal of Clinical Microbiology · doi:10.1128/jcm.r00092-09 · Cited by 88
Characterization and detection of artificial replication-competent lentivirus of altered host range
Segall, H., Yoo, E., & Sutton, R. E. (2003) · Molecular Therapy · doi:10.1016/s1525-0016(03)00134-5 · Cited by 39
Jordan, J. A., Ibe, C. O., Moore, M. S., Host, C., & Simon, G. L. (2012) · Journal of Clinical Virology · doi:10.1016/j.jcv.2012.01.004 · Cited by 18
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Isothermal Amplification of Nucleic Acids
Zhao, Y., Chen, F., Li, Q., Wang, L., & Fan, C. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00428 · Cited by 1,775
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Recombinase polymerase amplification: Basics, applications and recent advances
Lobato, I. M., & O'Sullivan, C. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.10.015 · Cited by 1,146
Recombinase Polymerase Amplification for Diagnostic Applications
Daher, R. K., Stewart, G., Boissinot, M., & Bergeron, M. G. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.245829 · Cited by 740
Metadata
- Authors
- Rohrman, B. A., & Richards-Kortum, R. R.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 12
- Issue
- 17
- Pages
- 3082
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2119289482
- Cited by
- 273
- References
- 24
- FWCI
- 13.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.