The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A highly selective ratiometric near-infrared fluorescent cyanine sensor for cysteine with remarkable shift and its application in bioimaging
Abstract
We developed a highly selective ratiometric near-infrared cyanine-based probe CyAC for cysteine (Cys) over homocysteine (Hcy) and glutathione (GSH). Upon the addition of Cys to the solution of CyAC, remarkable shifts in the spectra of CyAC can be monitored (from 770 nm to 515 nm in absorption spectra and from 780 nm to 570 nm in emission spectra). For the first time, the novel strategy that reversibly modulates the polymethine π-electron system by conjugation and removal of the specific trigger moiety was implemented for the generation of a ratiometric cyanine-based sensor. Hydroxy cyanine CyAE was chosen as the flurophore scaffold because the tautomerism (CyAE and CyAK or CyAD) can cause the reversible change in the π-conjugation system of the dyes with large shifts in the spectra. An acrylate group containing a α, β-unsaturated ketone as a functional trigger moiety was incorporated with CyAK to form the sensor CyAC. This specific response for Cys was based on the differences of the kinetics of intramolecular adduct/cyclizations. Moreover, CyAC was successfully applied for bioimaging Cys in living cancer cells. This paradigm by modulation of the polymethine π-electron system in the cyanine dye provides a promising methodology for the design of ratiometric cyanine-based sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescent and colorimetric probes for detection of thiols
Chen, X., Zhou, Y., Peng, X., & Yoon, J. (2010) · Chemical Society Reviews · doi:10.1039/b925092a · Cited by 1,580
Self-citation
Cited by
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Design strategies of fluorescent probes for selective detection among biothiols
Niu, L.-Y., Chen, Y.-Z., Zheng, H.-R., Wu, L.-Z., Tung, C.-H., & Yang, Q.-Z. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00152h · Cited by 870
Thiol-addition reactions and their applications in thiol recognition
Yin, C., Huo, F., Zhang, J., Martínez-Máñez, R., Yang, Y., Lv, H., & Li, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60055f · Cited by 554
A Reversible Fluorescent Probe for Real‐Time Quantitative Monitoring of Cellular Glutathione
Liu, Z., Zhou, X., Miao, Y., Hu, Y., Kwon, N., Wu, X., & Yoon, J. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201702114 · Cited by 312
Self-citationThiol Reactive Probes and Chemosensors
Peng, H., Chen, W., Cheng, Y., Hakuna, L., Strongin, R., & Wang, B. (2012) · Sensors · doi:10.3390/s121115907 · Cited by 275
Metadata
- Authors
- Guo, Z., Nam, S., Park, S., & Yoon, J.
- Venue
- Chemical Science
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2012
- Volume
- 3
- Issue
- 9
- Pages
- 2760
- ISSN
- 2041-6520 (ISSN-L)
- 2041-6539
- OpenAlex
- W2040349635
- Cited by
- 431
- References
- 1
- FWCI
- 23.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A highly selective ratiometric near-infrared fluorescent cyanine sensor for cysteine with remarkable shift and its application in bioimaging. https://app.cochat.ai/papers/10.1039/c2sc20540h
- The paper
- Guo, Z., Nam, S., Park, S., & Yoon, J. (2012). A highly selective ratiometric near-infrared fluorescent cyanine sensor for cysteine with remarkable shift and its application in bioimaging. Chemical Science. https://doi.org/10.1039/c2sc20540h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.