A conically fixed position single drop microextraction method for isolation of aryloxyphenoxypropionate herbicides from aquatic media
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A new and convenient format of single drop microextraction (SDME) was developed and applied for isolation of some selected aryloxyphenoxypropionate herbicides from aquatic media. In contrast to the conventional SDME procedure, in this set-up the extraction microdrop was positioned at the bottom of a conical vial in order to provide much higher stability for the organic extraction phase while a magnetic bar was used for stirring the aqueous solution. A simple magnet was used for positioning the bar on the top of the microdrop prior to stirring. The whole set-up led to the use of any volume of extraction solvent with unlimited stirring rates. Some important extraction parameters such as the type of solvent, stirring rate, temperature and extraction time were investigated and optimized. Selection of a microdrop volume of 3 μL with a sampling time of 35 min along with the use of carbon tetrachloride as the most appropriate solvent led to the highest enrichment factors. The linearity was studied by preconcentration of 1 mL of water samples spiked with a standard solution of aryloxyphenoxypropionates in the concentration range of 0.1–300 μg L−1. The coefficient of determination was satisfactory (r2 > 0.99) for all the studied analytes and the relative standard deviation (RSD%) values under the optimized conditions were found to be in the range of 5.1 to 10.1% at the concentrations of 0.6 and 50 μg L−1. Detection limits were obtained to be in the range of 0.02–0.05 μg L−1 using time-scheduled selected ion monitoring (SIM). The developed method was successfully applied for the extraction and determination of aryloxyphenoxypropionates in river water samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prosen, H., & Zupančič-Kralj, L. (1999) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(98)00109-5 · Cited by 565
Cited by
Deep eutectic solvent-based dispersive liquid-liquid microextraction
Farajzadeh, M. A., Afshar Mogaddam, M. R., & Aghanassab, M. (2016) · Analytical Methods · doi:10.1039/c5ay03189c · Cited by 141
Non-conventional solvents in liquid phase microextraction and aqueous biphasic systems
An, J., Trujillo-Rodríguez, M. J., Pino, V., & Anderson, J. L. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.04.012 · Cited by 128
Farajzadeh, M. A., Shahedi Hojghan, A., & Afshar Mogaddam, M. R. (2018) · Journal of Food Composition and Analysis · doi:10.1016/j.jfca.2017.12.007 · Cited by 99
Greening Sample Preparation: New Solvents, New Sorbents
Ramos, L. (2020) · Challenges in Green Analytical Chemistry · doi:10.1039/9781788016148-00114 · Cited by 6
Metadata
- Authors
- Bagheri, H., Dehghan, M., Es'haghi, A., & Naderi, M.
- Venue
- Analytical Methods
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 5
- Issue
- 18
- Pages
- 4846
- ISSN
- 1759-9660 (ISSN-L)
- 1759-9679
- OpenAlex
- W2091298268
- Cited by
- 21
- References
- 1
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.