Gd3+ spin labeling for distance measurements by pulse EPR spectroscopy
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Methods for measuring nanometer scale distances between specific sites in biomolecules (proteins and nucleic acids) and their complexes are essential for describing and analyzing their structure and function. In the last decade pulse EPR techniques were proven very effective for measuring distances between two spin labels attached to a biomolecule. The most commonly used spin labels for such measurements are nitroxide stable radicals. Recently, a new family of spin labels, based on Gd(3+) chelates, has been introduced to overcome some of the limitations of using nitroxides, particularly at high magnetic fields, which are attractive due to the increased sensitivity they offer. The benefits that such S = 7/2 spin labels offer for frequencies of 30 GHz and higher, particularly at 95 GHz, include (1) high sensitivity, only ∼0.15 nmol of doubly labeled biomolecule is needed, (2) the lack of orientation selection, which allows straightforward data analysis. Gd(3+)-Gd(3+) DEER (double electron-electron resonance) distance measurements on labeled peptides, proteins and DNA have already been demonstrated and the results show that they are very promising in terms of sensitivity. In this Perspective we review these new developments. We briefly introduce the characteristics of the DEER experiment on a pair of S = 1/2 spins and characterize the EPR spectroscopic properties of Gd(3+) ions. We then introduce some of the tags employed to attach Gd(3+) to biomolecules and provide a few experimental examples of Gd(3+)-Gd(3+) DEER measurements. This is followed by a discussion of the parameters that affect the sensitivity of such DEER measurements. Since an important term in the spin Hamiltonian of Gd(3+) is the zero-field splitting (ZFS), its effect on the DEER modulation frequencies must be considered and this is discussed next. Finally, another recently reported approach for using Gd(3+) in distance measurements will be presented: the use of Gd(3+)-nitroxide pairs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
EasySpin, a comprehensive software package for spectral simulation and analysis in EPR
Stoll, S., & Schweiger, A. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2005.08.013 · Cited by 6,557
Dead-Time Free Measurement of Dipole–Dipole Interactions between Electron Spins
Pannier, M., Veit, S., Godt, A., Jeschke, G., & Spiess, H. W. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1944 · Cited by 1,056
DeerAnalysis2006—a comprehensive software package for analyzing pulsed ELDOR data
Jeschke, G., Chechik, V., Ionita, P., Godt, A., Zimmermann, H., Banham, J., Timmel, C. R., Hilger, D., & Jung, H. (2006) · Applied Magnetic Resonance · doi:10.1007/bf03166213 · Cited by 1,050
Distance measurements on spin-labelled biomacromolecules by pulsed electron paramagnetic resonance
Jeschke, G., & Polyhach, Y. (2007) · Physical Chemistry Chemical Physics · doi:10.1039/b614920k · Cited by 611
Long-range distance determinations in biomacromolecules by EPR spectroscopy
Schiemann, O., & Prisner, T. F. (2007) · Quarterly Reviews of Biophysics · doi:10.1017/s003358350700460x · Cited by 557
Recent advances in site-directed spin labeling of proteins
Hubbell, W. L., Gross, A., Langen, R., & Lietzow, M. A. (1998) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(98)80158-9 · Cited by 550
Stone, T. J., Buckman, T., Nordio, P. L., & McConnell, H. M. (1965) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.54.4.1010 · Cited by 425
The determination of pair distance distributions by pulsed ESR using Tikhonov regularization
Chiang, Y.-W., Borbat, P. P., & Freed, J. H. (2005) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2004.10.012 · Cited by 400
Investigation of structure and dynamics in membrane proteins using site-directed spin labeling
Hubbell, W. L., & Altenbach, C. (1994) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(94)90219-4 · Cited by 389
Larsen, R. G., & Singel, D. J. (1993) · The Journal of Chemical Physics · doi:10.1063/1.464916 · Cited by 264
Cited by
Toward Molecular 4f Single-Ion Magnet Qubits
Pedersen, K. S., Ariciu, A.-M., McAdams, S., Weihe, H., Bendix, J., Tuna, F., & Piligkos, S. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b02702 · Cited by 270
Probing Protein Conformation in Cells by EPR Distance Measurements using Gd3+ Spin Labeling
Martorana, A., Bellapadrona, G., Feintuch, A., Di Gregorio, E., Aime, S., & Goldfarb, D. (2014) · Journal of the American Chemical Society · doi:10.1021/ja5079392 · Cited by 207
Self-citationFinding Our Way in the Dark Proteome
Bhowmick, A., Brookes, D. H., Yost, S. R., Dyson, H. J., Forman-Kay, J. D., Gunter, D., Head-Gordon, M., Hura, G. L., Pande, V. S., Wemmer, D. E., et al. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b06543 · Cited by 128
Metadata
- Authors
- Goldfarb, D.
- Venue
- Physical Chemistry Chemical Physics
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 16
- Issue
- 21
- Pages
- 9685
- ISSN
- 1463-9076 (ISSN-L)
- 1463-9084
- OpenAlex
- W2029613158
- Cited by
- 182
- References
- 30
- FWCI
- 10.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.