CoChat

Gd3+ spin labeling for distance measurements by pulse EPR spectroscopy

Goldfarb, Daniella · 2014 · Physical Chemistry Chemical Physics
Cited by 182

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

Methods for measuring nanometer scale distances between specific sites in biomolecules (proteins and nucleic acids) and their complexes are essential for describing and analyzing their structure and function. In the last decade pulse EPR techniques were proven very effective for measuring distances between two spin labels attached to a biomolecule. The most commonly used spin labels for such measurements are nitroxide stable radicals. Recently, a new family of spin labels, based on Gd(3+) chelates, has been introduced to overcome some of the limitations of using nitroxides, particularly at high magnetic fields, which are attractive due to the increased sensitivity they offer. The benefits that such S = 7/2 spin labels offer for frequencies of 30 GHz and higher, particularly at 95 GHz, include (1) high sensitivity, only ∼0.15 nmol of doubly labeled biomolecule is needed, (2) the lack of orientation selection, which allows straightforward data analysis. Gd(3+)-Gd(3+) DEER (double electron-electron resonance) distance measurements on labeled peptides, proteins and DNA have already been demonstrated and the results show that they are very promising in terms of sensitivity. In this Perspective we review these new developments. We briefly introduce the characteristics of the DEER experiment on a pair of S = 1/2 spins and characterize the EPR spectroscopic properties of Gd(3+) ions. We then introduce some of the tags employed to attach Gd(3+) to biomolecules and provide a few experimental examples of Gd(3+)-Gd(3+) DEER measurements. This is followed by a discussion of the parameters that affect the sensitivity of such DEER measurements. Since an important term in the spin Hamiltonian of Gd(3+) is the zero-field splitting (ZFS), its effect on the DEER modulation frequencies must be considered and this is discussed next. Finally, another recently reported approach for using Gd(3+) in distance measurements will be presented: the use of Gd(3+)-nitroxide pairs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3cp53822b

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 182

Metadata

Authors
Goldfarb, D.
Venue
Physical Chemistry Chemical Physics
Published
2014
Volume
16
Issue
21
Pages
9685
ISSN
  • 1463-9076 (ISSN-L)
  • 1463-9084
OpenAlex
W2029613158
Cited by
182
References
30
FWCI
10.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.