The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
A cap-type Schiff base acting as a fluorescence sensor for zinc(ii) and a colorimetric sensor for iron(ii), copper(ii), and zinc(ii) in aqueous media
Abstract
A simple and low cost chemosensor is described. This sensor could simultaneously detect three biologically important metal ions through fluorogenic (Zn(2+)) and chromogenic (Fe(2+), Cu(2+), and Zn(2+)) methods in aqueous solution. The sensor could function as a "turn-on" fluorescence receptor only to Zn(2+) ions. In addition, the sensor could be successfully applied to the detection of intracellular Zn(2+). Meanwhile, the sensor displayed an obvious red color upon selective binding with Fe(2+). Therefore, the sensor could serve as a useful tool for the discrimination of Fe(2+) from Fe(3+) in aqueous media. Moreover, the sensor also showed color changes from yellow to colorless upon selective binding with Zn(2+) and Cu(2+), respectively. The detection limit of the sensor for Cu(2+) (1.5 μM) is far below the guidelines of the World Health Organization (30 μM) as the maximum allowable copper concentration in drinking water, and therefore it is capable of being a practical system for the monitoring of Cu(2+) concentrations in aqueous samples. These results provide a new approach for selectively recognizing the most important three trace elements in the human body simultaneously, for Zn(2+) by emission spectra and Fe(2+), Cu(2+), and Zn(2+) by the naked eye.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Signaling Recognition Events with Fluorescent Sensors and Switches
de Silva, A. P., Gunaratne, H. Q. N., Gunnlaugsson, T., Huxley, A. J. M., McCoy, C. P., Rademacher, J. T., & Rice, T. E. (1997) · Chemical Reviews · doi:10.1021/cr960386p · Cited by 6,995
Neurodegenerative diseases and oxidative stress
Barnham, K. J., Masters, C. L., & Bush, A. I. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1330 · Cited by 3,683
Iron deficiency limits phytoplankton growth in the north-east Pacific subarctic
Martin, J. H., & Fitzwater, S. E. (1988) · Nature · doi:10.1038/331341a0 · Cited by 2,025
Metal–Salen Schiff base complexes in catalysis: practical aspects
Cozzi, P. G. (2004) · Chem. Soc. Rev. · doi:10.1039/b307853c · Cited by 1,978
A new trend in rhodamine-based chemosensors: application of spirolactam ring-opening to sensing ions
Kim, H. N., Lee, M. H., Kim, H. J., Kim, J. S., & Yoon, J. (2008) · Chemical Society Reviews · doi:10.1039/b802497a · Cited by 1,649
Self-citationIron accumulation in Alzheimer disease is a source of redox-generated free radicals
Smith, M. A., Harris, P. L. R., Sayre, L. M., & Perry, G. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.18.9866 · Cited by 1,355
The metallobiology of Alzheimer's disease
Bush, A. I. (2003) · Trends in Neurosciences · doi:10.1016/s0166-2236(03)00067-5 · Cited by 1,315
Jung, H. S., Kwon, P. S., Lee, J. W., Kim, J. I., Hong, C. S., Kim, J. W., Yan, S., Lee, J. Y., Lee, J. H., Joo, T., et al. (2009) · Journal of the American Chemical Society · doi:10.1021/ja808611d · Cited by 1,058
Jiang, P., & Guo, Z. (2004) · Coordination Chemistry Reviews · doi:10.1016/j.cct.2003.10.013 · Cited by 989
Iron and Oxidative Stress in Bacteria
Touati, D. (2000) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.1999.1518 · Cited by 924
Cited by
Fluorescent, MRI, and colorimetric chemical sensors for the first-row d-block metal ions
Zhu, H., Fan, J., Wang, B., & Peng, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00285g · Cited by 437
Metadata
- Authors
- Kim, K. B., Kim, H., Song, E. J., Kim, S., Noh, I., & Kim, C.
- Venue
- Dalton Transactions
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 42
- Issue
- 47
- Pages
- 16569
- ISSN
- 1477-9226 (ISSN-L)
- 1477-9234
- OpenAlex
- W1988941607
- Cited by
- 295
- References
- 49
- FWCI
- 13.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.