CoChat

Material requirements for membrane separators in a water-splitting photoelectrochemical cell

Berger, Alan, Segalman, R. A., Newman, J. · 2014 · Energy Environ. Sci.
Cited by 107

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

A fully integrated model of a photoelectrochemical cell for water electrolysis is applied to the case of light-absorbing particles embedded in a membrane separator. Composition of the product gases is shown to be one critical measure of device performance. Not only must the composition be kept outside the explosive window for mixtures of H2 and O2, but also product purity is a concern. For the absorber-in-membrane geometry and the model assumptions used here, results show purely water-saturated H2 on the cathode side and water-saturated O2 on the anode side. Since it is possible to design devices that violate these assumptions, it should not be assumed that a polymer separator or an absorber-in-membrane geometry will be effective in preventing explosive mixtures in all cases. Net H2 collected, iH2,net, is the second essential performance metric, and it is shown to differ significantly from the more commonly reported total H2 produced and operating current density. Schemes which co-evolve H2 and O2 violate the first metric and do not provide the second. A composite of triple-junction silicon absorbers in a Nafion membrane is shown to have an optimum thickness of 30 μm, dependent on the properties of the light absorber. Varying membrane properties reveals a tradeoff between conductivity, κm, and gas permeabilities, ψH2 and ψO2, that can potentially be exploited differently than in a fuel cell. Modulating the relative humidity (RH) is insufficient. The maximum iH2,net is calculated to be 6.97 mA cm−2 at RH = 30% relative to a value of 6.92 mA cm−2 at RH = 100%. The model identifies target material properties for new polymers. If ψ is dropped one order of magnitude below that of Nafion (ψ/ψNafion = 0.1), the optimum value for iH2,net increases by 63.5%. For ψ/ψNafion = 0.01, the optimum iH2,net increases by 73.5%, which compares favorably to the 74.5% improvement that would result if Nafion were made impermeable (ψ/ψNafion = 0). Meanwhile, κm can drop to a value of 1.2 × 10−3 S cm−1 (two orders of magnitude below liquid-equilibrated Nafion) with less than a 5% decline in iH2,net.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3ee43807d

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 107

Metadata

Authors
Berger, A., Segalman, R. A., & Newman, J.
Venue
Energy Environ. Sci.
Published
2014
Volume
7
Issue
4
Pages
1468-1476
ISSN
  • 1754-5692 (ISSN-L)
  • 1754-5706
OpenAlex
W2022351896
Cited by
107
References
3
FWCI
4.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Material requirements for membrane separators in a water-splitting photoelectrochemical cell. https://app.cochat.ai/papers/10.1039/c3ee43807d
The paper
Berger, A., Segalman, R. A., & Newman, J. (2014). Material requirements for membrane separators in a water-splitting photoelectrochemical cell. Energy Environ. Sci. https://doi.org/10.1039/c3ee43807d

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.