CoChat

Side view thrombosis microfluidic device with controllable wall shear rate and transthrombus pressure gradient

Open access
Muthard, Ryan W., Diamond, Scott L. · 2013 · Lab on a Chip
Cited by 73

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Hemodynamic conditions vary throughout the vasculature, creating diverse environments in which platelets must respond. To stop bleeding, a growing platelet deposit must be assembled in the presence of fluid wall shear stress (τw) and a transthrombus pressure gradient (ΔP) that drives bleeding. We designed a microfluidic device capable of pulsing a fluorescent solute through a developing thrombus forming on collagen ± tissue factor (TF), while independently controlling ΔP and τw. Computer control allowed step changes in ΔP with a rapid response time of 0.26 mm Hg s(-1) at either venous (5.2 dynes cm(-2)) or arterial (33.9 dynes cm(-2)) wall shear stresses. Side view visualization of thrombosis with transthrombus permeation allowed for quantification of clot structure, height, and composition at various ΔP. Clot height was reduced 20% on collagen/TF and 28% on collagen alone when ΔP was increased from 20.8 to 23.4 mm Hg at constant arterial shear stress. When visualized with a platelet-targeting thrombin sensor, intrathrombus thrombin levels decreased by 62% as ΔP was increased from 0 to 23.4 mm Hg across the thrombus-collagen/TF barrier, consistent with convective removal of thrombogenic solutes due to pressure-driven permeation. Independent of ΔP, the platelet deposit on collagen had a permeability of 5.45 × 10(-14) cm(2), while the platelet/fibrin thrombus on collagen/TF had a permeability of 2.71 × 10(-14) cm(2) (comparable to that of an intact endothelium). This microfluidic design allows investigation of the coupled processes of platelet deposition and thrombin/fibrin generation in the presence of controlled transthrombus permeation and wall shear stress.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/c3lc41332b

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 73

Metadata

Authors
Muthard, R. W., & Diamond, S. L.
Venue
Lab on a Chip
Published
2013
Volume
13
Issue
10
Pages
1883
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2093411638
Cited by
73
References
2
FWCI
7.06
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Side view thrombosis microfluidic device with controllable wall shear rate and transthrombus pressure gradient. https://app.cochat.ai/papers/10.1039/c3lc41332b
The paper
Muthard, R. W., & Diamond, S. L. (2013). Side view thrombosis microfluidic device with controllable wall shear rate and transthrombus pressure gradient. Lab on a Chip. https://doi.org/10.1039/c3lc41332b

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.