Droplet morphometry and velocimetry (DMV): a video processing software for time-resolved, label-free tracking of droplet parameters
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Emerging assays in droplet microfluidics require the measurement of parameters such as drop size, velocity, trajectory, shape deformation, fluorescence intensity, and others. While micro particle image velocimetry (μPIV) and related techniques are suitable for measuring flow using tracer particles, no tool exists for tracking droplets at the granularity of a single entity. This paper presents droplet morphometry and velocimetry (DMV), a digital video processing software for time-resolved droplet analysis. Droplets are identified through a series of image processing steps which operate on transparent, translucent, fluorescent, or opaque droplets. The steps include background image generation, background subtraction, edge detection, small object removal, morphological close and fill, and shape discrimination. A frame correlation step then links droplets spanning multiple frames via a nearest neighbor search with user-defined matching criteria. Each step can be individually tuned for maximum compatibility. For each droplet found, DMV provides a time-history of 20 different parameters, including trajectory, velocity, area, dimensions, shape deformation, orientation, nearest neighbour spacing, and pixel statistics. The data can be reported via scatter plots, histograms, and tables at the granularity of individual droplets or by statistics accrued over the population. We present several case studies from industry and academic labs, including the measurement of 1) size distributions and flow perturbations in a drop generator, 2) size distributions and mixing rates in drop splitting/merging devices, 3) efficiency of single cell encapsulation devices, 4) position tracking in electrowetting operations, 5) chemical concentrations in a serial drop dilutor, 6) drop sorting efficiency of a tensiophoresis device, 7) plug length and orientation of nonspherical plugs in a serpentine channel, and 8) high throughput tracking of >250 drops in a reinjection system. Performance metrics show that highest accuracy and precision is obtained when the video resolution is >300 pixels per drop. Analysis time increases proportionally with video resolution. The current version of the software provides throughputs of 2-30 fps, suggesting the potential for real time analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
A particle image velocimetry system for microfluidics
Santiago, J. G., Wereley, S. T., Meinhart, C. D., Beebe, D. J., & Adrian, R. J. (1998) · Experiments in Fluids · doi:10.1007/s003480050235 · Cited by 1,174
Ultrahigh-throughput screening in drop-based microfluidics for directed evolution
Agresti, J. J., Antipov, E., Abate, A. R., Ahn, K., Rowat, A. C., Baret, J.-C., Marquez, M., Klibanov, A. M., Griffiths, A. D., & Weitz, D. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910781107 · Cited by 1,149
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Droplet microfluidics for high-throughput biological assays
Guo, M. T., Rotem, A., Heyman, J. A., & Weitz, D. A. (2012) · Lab on a Chip · doi:10.1039/c2lc21147e · Cited by 1,040
Baret, J.-C., Miller, O. J., Taly, V., Ryckelynck, M., El-Harrak, A., Frenz, L., Rick, C., Samuels, M. L., Hutchison, J. B., Agresti, J. J., et al. (2009) · Lab on a Chip · doi:10.1039/b902504a · Cited by 951
Controlled encapsulation of single-cells into monodisperse picolitre drops
Edd, J. F., Di Carlo, D., Humphry, K. J., Köster, S., Irimia, D., Weitz, D. A., & Toner, M. (2008) · Lab on a Chip · doi:10.1039/b805456h · Cited by 511
Applications of Holography in Fluid Mechanics and Particle Dynamics
Katz, J., & Sheng, J. (2010) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-121108-145508 · Cited by 461
Pillar-induced droplet merging in microfluidic circuits
Niu, X., Gulati, S., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b813325e · Cited by 374
Microfluidic high-throughput encapsulation and hydrodynamic self-sorting of single cells
Chabert, M., & Viovy, J.-L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708321105 · Cited by 344
Programmable large area digital microfluidic array with integrated droplet sensing for bioassays
Hadwen, B., Broder, G. R., Morganti, D., Jacobs, A., Brown, C., Hector, J. R., Kubota, Y., & Morgan, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40273d · Cited by 211
A microdroplet dilutor for high-throughput screening
Niu, X., Gielen, F., Edel, J. B., & deMello, A. J. (2011) · Nature Chemistry · doi:10.1038/nchem.1046 · Cited by 199
A multi-color fast-switching microfluidic droplet dye laser
Tang, S. K. Y., Li, Z., Abate, A. R., Agresti, J. J., Weitz, D. A., Psaltis, D., & Whitesides, G. M. (2009) · Lab on a Chip · doi:10.1039/b914066b · Cited by 195
Droplet sorting based on the number of encapsulated particles using a solenoid valve
Cao, Z., Chen, F., Bao, N., He, H., Xu, P., Jana, S., Jung, S., Lian, H., & Lu, C. (2012) · Lab on a Chip · doi:10.1039/c2lc40950j · Cited by 105
Cited by
Controlled multistep synthesis in a three-phase droplet reactor
Nightingale, A. M., Phillips, T. W., Bannock, J. H., & de Mello, J. C. (2014) · Nature Communications · doi:10.1038/ncomms4777 · Cited by 195
Collins, D. J., Neild, A., & Ai, Y. (2016) · Lab on a Chip · doi:10.1039/c5lc01335f · Cited by 190
Metadata
- Authors
- Basu, A. S.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 10
- Pages
- 1892
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2154166372
- Cited by
- 218
- References
- 16
- FWCI
- 5.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.