Cardiac-like flow generator for long-term imaging of endothelial cell responses to circulatory pulsatile flow at microscale
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In vitro models of circulatory hemodynamics are required to mimic the microcirculation for study of endothelial cell responses to pulsatile shear stress by live cell imaging. This study reports the design, fabrication and characterisation of a microfluidic device that generates cardiac-like flow in a continuous culture system with a circulatory volume of only 2-3 μL. The device mimics a single chamber heart, with the following cardiac phases: (1) closure of the ventricle inlet valve, (2) contraction of the ventricle (systole) followed by opening of the outlet valve and (3) relaxation of the ventricle (diastole) with opening of the inlet valve whilst the outlet valve remains closed. Periodic valve states and ventricular contractions were actuated by microprocessor controlled pneumatics. The time-dependent velocity-field was characterised by micro-particle image velocimetry (μ-PIV). μ-PIV observations were used to help tune electronic timing of valve states and ventricular contractions for synthesis of an arterial pulse waveform to study the effect of pulsatile shear stress on bovine artery endothelial cells (BAECs). BAECs elongated and aligned with the direction of shear stress after 48 h of exposure to a pulsatile waveform with a maximum shear stress of 0.42 Pa. The threshold for BAECs alignment and elongation under steady (non-pulsatile) flow reported by Kadohama et al. (2006) is 0.7-1.4 Pa. These cells respond to transient shear stress because the time average shear stress of the pulse waveform to generate this morphological response was only 0.09 Pa, well below the steady flow threshold. The microfluidic pulse generator can simulate circulatory hemodynamics for live cell imaging of shear-induced signalling pathways.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Cited by
Marsano, A., Conficconi, C., Lemme, M., Occhetta, P., Gaudiello, E., Votta, E., Cerino, G., Redaelli, A., & Rasponi, M. (2016) · Lab on a Chip · doi:10.1039/c5lc01356a · Cited by 447
Biomimetic 3D tissue models for advanced high-throughput drug screening
Nam, K.-H., Smith, A. S. T., Lone, S., Kwon, S., & Kim, D.-H. (2015) · SLAS Technology · doi:10.1177/2211068214557813 · Cited by 171
“Through the use of bioreactors, it is possible to replicate these forces and thereby influence endothelial cell alignment in vitro.(47) Bioreactors that generate dynamic flow culture systems provide a nutrient-rich environment in which external forces can be applied to cultures, thereby resulting in tissues with incre…”
BackgroundFlow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
Busek, M., Nøvik, S., Aizenshtadt, A., Amirola-Martinez, M., Combriat, T., Grünzner, S., & Krauss, S. (2021) · Biosensors · doi:10.3390/bios11050162 · Cited by 41
“1 dyne/cm2) and, thus, in the physiological range of endothelial cells (1–20 dyne/cm2) [13,41,42].”
Background
Metadata
- Authors
- Chen, H., Cornwell, J., Zhang, H., Lim, T., Resurreccion, R., Port, T., Rosengarten, G., & Nordon, R. E.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 13
- Issue
- 15
- Pages
- 2999
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2102128408
- Cited by
- 76
- References
- 2
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.