Protein corona affects the relaxivity and MRI contrast efficiency of magnetic nanoparticles
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Magnetic nanoparticles (NPs) are increasingly being considered for use in biomedical applications such as biosensors, imaging contrast agents and drug delivery vehicles. In a biological fluid, proteins associate in a preferential manner with NPs. The small sizes and high curvature angles of NPs influence the types and amounts of proteins present on their surfaces. This differential display of proteins bound to the surface of NPs can influence the tissue distribution, cellular uptake and biological effects of NPs. To date, the effects of adsorption of a protein corona (PC) on the magnetic properties of NPs have not been considered, despite the fact that some of their potential applications require their use in human blood. Here, to investigate the effects of a PC (using fetal bovine serum) on the MRI contrast efficiency of superparamagnetic iron oxide NPs (SPIONs), we have synthesized two series of SPIONs with variation in the thickness and functional groups (i.e. surface charges) of the dextran surface coating. We have observed that different physico-chemical characteristics of the dextran coatings on the SPIONs lead to the formation of PCs of different compositions. (1)H relaxometry was used to obtain the longitudinal, r1, and transverse, r2, relaxivities of the SPIONs without and with a PC, as a function of the Larmor frequency. The transverse relaxivity, which determines the efficiency of negative contrast agents (CAs), is very much dependent on the functional group and the surface charge of the SPIONs' coating. The presence of the PC did not alter the relaxivity of plain SPIONs, while it slightly increased the relaxivity of the negatively charged SPIONs and dramatically decreased the relaxivity of the positively charged ones, which was coupled with particle agglomeration in the presence of the proteins. To confirm the effect of the PC on the MRI contrast efficiency, in vitro MRI experiments at ν = 8.5 MHz were performed using a low-field MRI scanner. The MRI contrasts, produced by different samples, were fully in agreement with the relaxometry findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852 · cited 3×
“In fact, the main mechanisms that induce nuclear longitudinal relaxation in the SPIONs are as follows:[23, 31] (a) for ν < 1-5 MHz, the Neel relaxation of the particle magnetization, giving a correlation time related to the magnetic anisotropy barrier, and an associated reversal time, τN, that follows the Arrhenius la…”
BackgroundMethodSelf-citationMonopoli, M. P., Walczyk, D., Campbell, A., Elia, G., Lynch, I., Baldelli Bombelli, F., & Dawson, K. A. (2011) · Journal of the American Chemical Society · doi:10.1021/ja107583h · Cited by 1,835
Self-citationImmunological properties of engineered nanomaterials
Dobrovolskaia, M. A., & McNeil, S. E. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.223 · Cited by 1,823 · cited 1×
“[7] Superparamagnetic iron oxide nanoparticles (SPIONs) have been recognized as very promising nanosystems with good biocompatibility[8, 9] and high potential to be used for diagnosis and therapy simultaneously.[8, 10-15] SPIONs have been extensively studied for both in vitro and in vivo biomedical applications, such…”
BackgroundAmstad, E., Kohlbrecher, J., Müller, E., Schweizer, T., Textor, M., & Reimhult, E. (2011) · Nano Letters · doi:10.1021/nl2001499 · Cited by 397 · cited 1×
“[7] Superparamagnetic iron oxide nanoparticles (SPIONs) have been recognized as very promising nanosystems with good biocompatibility[8, 9] and high potential to be used for diagnosis and therapy simultaneously.[8, 10-15] SPIONs have been extensively studied for both in vitro and in vivo biomedical applications, such…”
Background
Cited by
Fundamentals and advances in magnetic hyperthermia
Périgo, E. A., Hemery, G., Sandre, O., Ortega, D., Garaio, E., Plazaola, F., & Teran, F. J. (2015) · Applied Physics Reviews · doi:10.1063/1.4935688 · Cited by 836
A Decade of the Protein Corona
Ke, P. C., Lin, S., Parak, W. J., Davis, T. P., & Caruso, F. (2017) · ACS Nano · doi:10.1021/acsnano.7b08008 · Cited by 672
Structure–Relaxivity Relationships of Magnetic Nanoparticles for Magnetic Resonance Imaging
Zhou, Z., Yang, L., Gao, J., & Chen, X. (2019) · Advanced Materials · doi:10.1002/adma.201804567 · Cited by 488
Laurent, S., Saei, A. A., Behzadi, S., Panahifar, A., & Mahmoudi, M. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.924501 · Cited by 445
Self-citationEngineered Nanomaterials in Food: Implications for Food Safety and Consumer Health
Martirosyan, A., & Schneider, Y.-J. (2014) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph110605720 · Cited by 263
Metadata
- Authors
- Amiri, H., Bordonali, L., Lascialfari, A., Wan, S., Monopoli, M. P., Lynch, I., Laurent, S., & Mahmoudi, M.
- Venue
- Nanoscale
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2013
- Volume
- 5
- Issue
- 18
- Pages
- 8656
- ISSN
- 2040-3364 (ISSN-L)
- 2040-3372
- OpenAlex
- W2161851115
- Cited by
- 108
- References
- 4
- FWCI
- 7.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.