The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
3D printed microfluidic devices with integrated versatile and reusable electrodes
Open accessAbstract
We present two 3D printed fluidic devices capable of 1) flow-based electrochemical determination of dopamine and nitric oxide and 2) electrochemical measurement of oxygen while simultaneously collecting secreted molecules from red blood cells exposed to varying oxygen tensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Evaluation of 3D Printing and Its Potential Impact on Biotechnology and the Chemical Sciences
Gross, B. C., Erkal, J. L., Lockwood, S. Y., Chen, C., & Spence, D. M. (2014) · Analytical Chemistry · doi:10.1021/ac403397r · Cited by 1,746
Self-citationIntegrated 3D-printed reactionware for chemical synthesis and analysis
Symes, M. D., Kitson, P. J., Yan, J., Richmond, C. J., Cooper, G. J. T., Bowman, R. W., Vilbrandt, T., & Cronin, L. (2012) · Nature Chemistry · doi:10.1038/nchem.1313 · Cited by 617
Scaffold development using 3D printing with a starch-based polymer
Lam, C. X. F., Mo, X. M., Teoh, S. H., & Hutmacher, D. W. (2002) · Materials Science and Engineering: C · doi:10.1016/s0928-4931(02)00012-7 · Cited by 614
Configurable 3D-Printed millifluidic and microfluidic ‘lab on a chip’ reactionware devices
Kitson, P. J., Rosnes, M. H., Sans, V., Dragone, V., & Cronin, L. (2012) · Lab on a Chip · doi:10.1039/c2lc40761b · Cited by 484
An electrochemical microprobe for detecting nitric oxide release in brain tissue
Shibuki, K. (1990) · Neuroscience Research · doi:10.1016/0168-0102(90)90048-j · Cited by 413
Waldbaur, A., Rapp, H., Länge, K., & Rapp, B. E. (2011) · Analytical Methods · doi:10.1039/c1ay05253e · Cited by 381
Kristensen, E. W., Kuhr, W. G., & Wightman, R. M. (1987) · Analytical Chemistry · doi:10.1021/ac00141a003 · Cited by 258
A 3D Printed Fluidic Device that Enables Integrated Features
Anderson, K. B., Lockwood, S. Y., Martin, R. S., & Spence, D. M. (2013) · Analytical Chemistry · doi:10.1021/ac4009594 · Cited by 229
Self-citationKitson, P. J., Symes, M. D., Dragone, V., & Cronin, L. (2013) · Chem. Sci. · doi:10.1039/c3sc51253c · Cited by 180
3D-printed devices for continuous-flow organic chemistry
Dragone, V., Sans, V., Rosnes, M. H., Kitson, P. J., & Cronin, L. (2013) · Beilstein Journal of Organic Chemistry · doi:10.3762/bjoc.9.109 · Cited by 174
Dusseiller, M. R., Schlaepfer, D., Koch, M. C., Kroschewski, R., & Textor, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.032 · Cited by 153
Антонов, Е. Н., Bagratashvili, V. N., Whitaker, M. J., Barry, J. J. A., Shakesheff, K. M., Коновалов, А. Н., Popov, V. K., & Howdle, S. M. (2004) · Advanced Materials · doi:10.1002/adma.200400838 · Cited by 136
Dual Conductivity/Amperometric Detection System for Microchip Capillary Electrophoresis
Wang, J., & Pumera, M. (2002) · Analytical Chemistry · doi:10.1021/ac020416q · Cited by 131
Simultaneous electrochemical measurements of oxygen and dopamine in vivo
Zimmerman, J. B., & Wightman, R. M. (1991) · Analytical Chemistry · doi:10.1021/ac00001a005 · Cited by 119
Lee, Y., Oh, B. K., & Meyerhoff, M. E. (2003) · Analytical Chemistry · doi:10.1021/ac035064h · Cited by 110
Fluorinated Xerogel-Derived Microelectrodes for Amperometric Nitric Oxide Sensing
Shin, J. H., Privett, B. J., Kita, J. M., Wightman, R. M., & Schoenfisch, M. H. (2008) · Analytical Chemistry · doi:10.1021/ac800185x · Cited by 105
Rapid Prototyping of Thermoset Polyester Microfluidic Devices
Fiorini, G. S., Lorenz, R. M., Kuo, J. S., & Chiu, D. T. (2004) · Analytical Chemistry · doi:10.1021/ac0498922 · Cited by 102
Chen, C., Wang, Y., Lockwood, S. Y., & Spence, D. M. (2014) · The Analyst · doi:10.1039/c3an02357e · Cited by 80
Self-citationRecent Advances in 3D Printing of Tissue Engineering Scaffolds
Lee, M., & Wu, B. M. (2012) · Methods in molecular biology · doi:10.1007/978-1-61779-764-4_15 · Cited by 79
Yang, Z., Sasaki, S., Karube, I., & Suzuki, H. R. (1997) · Analytica Chimica Acta · doi:10.1016/s0003-2670(97)00560-6 · Cited by 65
Jobst, G., Urban, G. A., Jachimowicz, A., Köhl, F., Tilado, O., Lettenbichler, I., & Nauer, G. E. (1993) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(93)85024-i · Cited by 62
Needle-type dissolved oxygen microelectrode array sensors for in situ measurements
Lee, J., Lim, T.-S., Seo, Y., Bishop, P. L., & Papautsky, I. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.06.008 · Cited by 60
Bowen, A. L., & Martin, R. S. (2010) · Electrophoresis · doi:10.1002/elps.201000029 · Cited by 54
Self-citationKisler, K., Kim, B. N., Liu, X., Berberian, K., Fang, Q., Mathai, C. J., Gangopadhyay, S., Gillis, K. D., & Lindau, M. (2012) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2012.322030 · Cited by 50
Determination of blood pO2 using a micromachined Clark-type oxygen electrode
Suzuki, H. R., Hirakawa, T., Watanabe, I., & Kikuchi, Y. (2001) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)01325-8 · Cited by 49
Kovarik, M. L., Li, M. W., & Martin, R. S. (2004) · Electrophoresis · doi:10.1002/elps.200406188 · Cited by 44
Self-citationMeasuring the simultaneous effects of hypoxia and deformation on ATP release from erythrocytes
Faris, A. N., & Spence, D. M. (2008) · The Analyst · doi:10.1039/b719990b · Cited by 43
Self-citationMicrofabricated solid-state dissolved oxygen sensor
McLaughlin, G. W., Braden, K., Franc, B. L., & Kovacs, G. T. A. (2002) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(02)00021-7 · Cited by 42
Halpin, S. T., & Spence, D. M. (2010) · Analytical Chemistry · doi:10.1021/ac101130s · Cited by 38
Self-citationJohnson, A. S., Anderson, K. B., Halpin, S. T., Kirkpatrick, D. C., Spence, D. M., & Martin, R. S. (2012) · The Analyst · doi:10.1039/c2an36168j · Cited by 37
Self-citationSelimovic, A., & Martin, R. S. (2013) · Electrophoresis · doi:10.1002/elps.201300163 · Cited by 27
Self-citationMicrochip-based electrochemical detection for monitoring cellular systems
Johnson, A. S., Selimovic, A., & Martin, R. S. (2013) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6682-3 · Cited by 26
Self-citationAnderson, K. B., Halpin, S. T., Johnson, A. S., Martin, R. S., & Spence, D. M. (2012) · The Analyst · doi:10.1039/c2an36171j · Cited by 24
Self-citation
Cited by
Continuous liquid interface production of 3D objects
Tumbleston, J. R., Shirvanyants, D., Ermoshkin, N., Janusziewicz, R., Johnson, A. R., Kelly, D., Chen, K., Pinschmidt, R., Rolland, J. P., Ermoshkin, A., et al. (2015) · Science · doi:10.1126/science.aaa2397 · Cited by 2,278
The upcoming 3D-printing revolution in microfluidics
Bhattacharjee, N., Urrios, A., Kang, S., & Folch, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00163g · Cited by 1,123
3D-printing technologies for electrochemical applications
Ambrosi, A., & Pumera, M. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00714c · Cited by 1,040
3D printed microfluidic devices: enablers and barriers
Waheed, S., Cabot, J. M., Macdonald, N. P., Lewis, T., Guijt, R. M., Paull, B., & Breadmore, M. C. (2016) · Lab on a Chip · doi:10.1039/c6lc00284f · Cited by 1,039
Electrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Metadata
- Authors
- Erkal, J. L., Selimovic, A., Gross, B. C., Lockwood, S. Y., Walton, E. L., McNamara, S., Martin, R. S., & Spence, D. M.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 14
- Issue
- 12
- Pages
- 2023-2032
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2135859047
- Cited by
- 287
- References
- 34
- FWCI
- 17.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.