Body-on-a-chip simulation with gastrointestinal tract and liver tissues suggests that ingested nanoparticles have the potential to cause liver injury
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
The use of nanoparticles in medical applications is highly anticipated, and at the same time little is known about how these nanoparticles affect human tissues. Here we have simulated the oral uptake of 50 nm carboxylated polystyrene nanoparticles with a microscale body-on-a-chip system (also referred to as multi-tissue microphysiological system or micro Cell Culture Analog). Using the 'GI tract-liver-other tissues' system allowed us to observe compounding effects and detect liver tissue injury at lower nanoparticle concentrations than was expected from experiments with single tissues. To construct this system, we combined in vitro models of the human intestinal epithelium, represented by a co-culture of enterocytes (Caco-2) and mucin-producing cells (TH29-MTX), and the liver, represented by HepG2/C3A cells, within one microfluidic device. The device also contained chambers that together represented the liquid portions of all other organs of the human body. Measuring the transport of 50 nm carboxylated polystyrene nanoparticles across the Caco-2/HT29-MTX co-culture, we found that this multi-cell layer presents an effective barrier to 90.5 ± 2.9% of the nanoparticles. Further, our simulation suggests that a larger fraction of the 9.5 ± 2.9% nanoparticles that travelled across the Caco-2/HT29-MTX cell layer were not large nanoparticle aggregates, but primarily single nanoparticles and small aggregates. After crossing the GI tract epithelium, nanoparticles that were administered in high doses estimated in terms of possible daily human consumption (240 and 480 × 10(11) nanoparticles mL(-1)) induced the release of aspartate aminotransferase (AST), an intracellular enzyme of the liver that indicates liver cell injury. Our results indicate that body-on-a-chip devices are highly relevant in vitro models for evaluating nanoparticle interactions with human tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“At the same time, they overcame the inaccessibility of cystic organoids and clearance of cell debris by creating a perfusable culture of mini-intestines where cells are arranged to form tube-shaped epithelia and similar spatial arrangement as the in vivo tissue100.”
From Organoids (2022) · cites this paper as [100]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“creation of Intestine Chips can facilitate study of drug breakdown both alone and when coupled to other Organ Chips that also contribute to drug metabolism (eg, Liver Chip) and clearance (eg, Kidney Chip) in a human Body-on-a-Chip configuration.36, 37”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [37]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Pooling together different cells and/or organoids for bulk analysis can lead to inaccurate results3,70,100,204,207,208.”
From Organoids (2022) · cites this paper as [100]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Some devices integrated multiple chambers with different types of cells to measure PK and pharmacodynamics (PD) properties of drug compounds in vitro.35, 36, 37”
From Microfluidic Organ-on-a-Chip Models of Human Intestine (2018) · cites this paper as [37]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological Parameters in Laboratory Animals and Humans
Davies, B., & Morris, T. (1993) · Pharmaceutical Research · doi:10.1023/a:1018943613122 · Cited by 2,926
Lundqvist, M., Stigler, J., Elia, G., Lynch, I., Cedervall, T., & Dawson, K. A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805135105 · Cited by 2,823
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Treating metastatic cancer with nanotechnology
Schroeder, A., Heller, D. A., Winslow, M. M., Dahlman, J. E., Pratt, G. W., Langer, R., Jacks, T., & Anderson, D. G. (2012) · Nature Reviews Cancer · doi:10.1038/nrc3180 · Cited by 1,159
Tzima, E. (2001) · The EMBO Journal · doi:10.1093/emboj/20.17.4639 · Cited by 569
A toxicologist guide to the diagnostic interpretation of hepatic biochemical parameters
Ramaiah, S. K. (2007) · Food and Chemical Toxicology · doi:10.1016/j.fct.2007.06.007 · Cited by 494
Revisiting lab-on-a-chip technology for drug discovery
Neužil, P., Giselbrecht, S., Länge, K., Huang, T. J., & Manz, A. (2012) · Nature Reviews Drug Discovery · doi:10.1038/nrd3799 · Cited by 487
Nanoparticle-induced surface reconstruction of phospholipid membranes
Wang, B., Zhang, L., Bae, S. C., & Granick, S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807296105 · Cited by 469
Evaluation of nanoparticle immunotoxicity
Dobrovolskaia, M. A., Germolec, D. R., & Weaver, J. L. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.175 · Cited by 368
Oral exposure to polystyrene nanoparticles affects iron absorption
Mahler, G. J., Esch, M. B., Tako, E., Southard, T. L., Archer, S. D., Glahn, R. P., & Shuler, M. L. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.3 · Cited by 340
Cited by
Items 201–281 of 281
Building an experimental model of the human body with non-physiological parameters
Labuz, J. M., Moraes, C., Mertz, D. R., Leung, B. M., & Takayama, S. (2017) · TECHNOLOGY · doi:10.1142/s2339547817500029 · Cited by 11
Miyazaki, T., Hirai, Y., Kamei, K., Tsuchiya, T., & Tabata, O. (2020) · Electronics and Communications in Japan · doi:10.1002/ecj.12296 · Cited by 11
Development of a Perfusing Small Intestine–Liver Microphysiological System Device
Sakai, Y., Matsumura, M., Yamada, H., Doi, A., Saito, I., Iwao, T., & Matsunaga, T. (2023) · Applied Sciences · doi:10.3390/app131810510 · Cited by 11
“The microphysiological systems (MPS) model has garnered increasing attention as a new tool for cell assays in drug discovery research by combining microfluidic devices and cell culture technologies [2].”
MethodGholizadeh, H., Cheng, S., Kourmatzis, A., Xing, H., Traini, D., Young, P. M., & Ong, H. X. (2022) · Bioengineering · doi:10.3390/bioengineering9040150 · Cited by 11
“Determining toxicity early in the drug discovery pipeline remains a challenge, as animal studies do not efficiently predict toxicity responses in human [3,58].”
BackgroundUtilizing Nanomaterials in Microfluidic Devices for Disease Detection and Treatment
Tian, Z., Fu, Y., Dang, Z., Guo, T., Li, W., & Zhang, J. (2025) · Nanomaterials · doi:10.3390/nano15060434 · Cited by 10
“B. Esch et al. discovered that carboxylated polystyrene NPs are capable of penetrating intestinal epithelial cells and entering liver tissues, causing sublethal damage to hepatocytes at high doses [153].”
Abdessalam, S., Hardy, T. J., Pershina, D., & Yoon, J. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117472 · Cited by 11
Microbiota‐gut‐brain axis multi‐organ chip construction and applications in drug evaluation
Tang, Y., Chen, H., Zhao, Z., Kang, X., Wang, W., Dai, K., Guo, Y., Liang, A., Luo, A., & Hao, Z. (2025) · iMetaOmics. · doi:10.1002/imo2.70065 · Cited by 11
“Esch et al. [123] developed a static MOC containing gastrointestinal, liver, and other tissue modules to study the composite effect of nanoparticle ‐ tissue interactions (Figure 5E).”
Yuvika, Sharma, D., & Sharma, A. (2026) · Comparative Biochemistry and Physiology Part C Toxicology & Pharmacology · doi:10.1016/j.cbpc.2026.110473 · Cited by 12
Pumped and pumpless microphysiological systems to study (nano)therapeutics
Lee, E. J., Krassin, Z. L., Abaci, H. E., Mahler, G. J., & Esch, M. B. (2023) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1911 · Cited by 10
Design principles for dynamic microphysiological systems
Cooper, M. H., Charest, J. L., & Coppeta, J. R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813671-3.00001-3 · Cited by 11
A simple cell transport device keeps culture alive and functional during shipping
Miller, P. G., Wang, Y. I., Swan, G., & Shuler, M. L. (2017) · Biotechnology Progress · doi:10.1002/btpr.2512 · Cited by 9
Ueno, H., Yamada, K., & Suzuki, T. (2018) · Micromachines · doi:10.3390/mi9120681 · Cited by 8
Design and construction of in vitro digestive simulation model
Li, Y., Yuan, Z., Shi, A., Xiang, Z., & Zhang, H. (2024) · International Journal of Food Science & Technology · doi:10.1111/ijfs.17487 · Cited by 7
Babboni, S., Vacca, P. G., Simonini, L., Pezzati, D., Martinelli, C., Frongillo, F., Bianco, G., Marciano, E., Basta, G., Ghinolfi, D., et al. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13061804 · Cited by 10
“Identifying key signals can provide targeted therapeutic pathways and enable the development of therapies to enhance liver regeneration [74,122].”
BackgroundMitxelena‐Iribarren, O., Olaizola‐Rodrigo, C., Arana, S., & Mujika, M. (2021) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2021.102462 · Cited by 9
Singh, A. K. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-801406-6.00005-4 · Cited by 13
Design and engineering of multiorgan systems
Renggli, K., & Frey, O. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00012-7 · Cited by 8
Gut-on-a-chip microphysiological systems for the recapitulation of the gut microenvironment
Lee, S. H., & Sung, J. H. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817202-5.00010-3 · Cited by 7
Das, A., Rani, P., Dastider, S. G., Mondal, K., & Alegaonkar, P. S. (2024) · ChemistrySelect · doi:10.1002/slct.202400032 · Cited by 6
Hu, W., Sun, H., Qi, H., Jiang, L., Zhang, K., Jia, X., Wang, Y., Xiang, Y., & Liang, Q. (2025) · Lab on a Chip · doi:10.1039/d5lc00015g · Cited by 7
McCormick, S., Smith, L. E., Holmes, A. M., Tong, Z., Lombi, E., Voelcker, N. H., & Priest, C. (2019) · Biomicrofluidics · doi:10.1063/1.5113729 · Cited by 6
Biological Applications of Microfluidics System
Solanki, S., & Pandey, C. M. (2016) · Springer eBooks · doi:10.1007/978-3-319-40036-5_8 · Cited by 8
Robust fluidic connections to freestanding microfluidic hydrogels
Faley, S. L., Baer, B. B., Larsen, T. S. H., & Bellan, L. M. (2015) · Biomicrofluidics · doi:10.1063/1.4921453 · Cited by 5
Walczak, A. P. (2015) · doi:10.18174/327363 · Cited by 7
Jozani, K. A., Shen, K., Anvari, N., Hocevar, D., Jiang, R., Zhang, B., Yakavets, I., & Zhao, Y. (2026) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2026.115835 · Cited by 8
Rheological characterization and print quality studies of gelatin/collagen I/PEGDA hydrogels
Bartholomew, K., & Mahapatro, A. (2024) · International Journal of Polymeric Materials · doi:10.1080/00914037.2024.2391964 · Cited by 8
An Intestine/Liver Microphysiological System for Drug Pharmacokinetic and Toxicological Assessment
Marin, T. M., Indolfo, N. D. C., Rocco, S. A., Carvalho, M. D. O., Dias, M. M., Bento, G. I. V., Bortot, L. O., Schuck, D. C., Lorencini, M., & Pagani, E. (2020) · Journal of Visualized Experiments · doi:10.3791/60184 · Cited by 7
Yang, Y., Liu, S., & Geng, J. (2019) · Current Pharmaceutical Design · doi:10.2174/1381612825666190730100051 · Cited by 5
Alfred, M. O., Ochola, L. B., Okeyo, K. O., Bae, E., Ogongo, P., Odongo, D., Njaanake, K. H., & Robinson, J. P. (2025) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2025.1521265 · Cited by 5
New Combination/Application of Polymer-Based Nanoparticles for Biomedical Engineering
Chang, R., Wang, P., & Tseng, C. (2018) · Advances in experimental medicine and biology · doi:10.1007/978-981-13-0950-2_14 · Cited by 4
Application of 3D Cell Culture Techniques in Nanotoxicology: How Far Are We?
Shakeri, R., Mirjalili, S. Z., Karakuş, C. Ö., & Safavi, M. (2026) · Stem Cell Reviews and Reports · doi:10.1007/s12015-025-11052-x · Cited by 3
“Esh and coworkers simulated livery injury from ingested 50 nm carboxylated polystyrene NPs caused by gastrointestinal tract and liver tissue cross-talk using liver-on-a-chip (integrated with intestine-on-a-chip) [ 233].”
Optimized decolorization of aniline blue dye using potassium ferrate (VI)
Goutomo, B. T., Ouzar, A., & Kim, I. (2025) · Desalination and Water Treatment · doi:10.1016/j.dwt.2025.101006 · Cited by 3
Microfluidic devices and their applicability to cell studies
Fernandes, A. C., Semenova, D., & Grundtvig, I. P. R. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-822482-3.00003-8 · Cited by 2
Lu, R. X. Z., Zhao, Y., & Radisic, M. (2023) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10581 · Cited by 3
“…in vitro platforms hold the potential to faithfully recapitulate the pharmacokinetic and pharmacodynamic properties of therapeutic agents, 165,166 and to enrich understanding of viral pathogenesis within a biological milieu akin to in vivo conditions, all the while circumventing the…”
BackgroundMarin, T. M., & Pagani, E. (2018) · Vigilância Sanitária em Debate · doi:10.22239/2317-269x.01053 · Cited by 5
Gut Microbiome and Drug Metabolism
Ilina, E. N., Mayorova, E. M., Manolov, A. I., Korenkova, A. A., Bahmetjev, V. V., & Gorbunov, K. (2021) · Biomedical Chemistry Research and Methods · doi:10.18097/bmcrm00146 · Cited by 3
Advanced Gut-on-a-Chip In Vitro Models for ENMs Safety Assessment
Neto, M. D., Pastrana, L. M., & Gonçalves, C. (2025) · Springer eBooks · doi:10.1007/978-3-031-93871-9_8 · Cited by 2
Microphysiological systems for modeling gut-organ interaction
Sung, J. H. (2024) · Biocell · doi:10.32604/biocell.2024.050365 · Cited by 2
“Based on these early attempts, a micro fl uidic chip for studying the effect of orally taken nanoparticles on liver injury was published [23], which was further advanced by utilizing the integration of single-organ chips with modular design [24], and also expanded to accommodate up to 14…”
MethodAdvances in Organ-on-a-chip Technologies for Biomedical Research and Applications
Zhu, Q., Liao, M., Hu, Y., & Chai, R. (2025) · Materials Lab · doi:10.54227/mlab.20240006 · Cited by 2
Efficacy and safety of combined etanercept and iguratimod for active rheumatoid arthritis
Sun, Y., Wang, P., Wang, L., Li, H., Li, M., Xu, Y. C., Sun, W., Wang, L., Yang, Y., Zhang, X., et al. (2016) · Biomedical Research-tokyo · Cited by 2
Miyazaki, T., Hirai, Y., Kamei, K., Tsuchiya, T., & Tabata, O. (2020) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.140.285 · Cited by 2
The use of organ-on-a-chip methods for testing of nanomaterials
Pountos, I., Tutar, R., Tellisi, N., Darabi, M. A., Hasan, A., & Ashammakhi, N. A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-820558-7.00008-x · Cited by 2
Ultralow and Dynamic Flow Field Generator Composed of Microfluidic Peristaltic Pump
Che, B., Sun, D., Yan, N., Zhao, W., Liu, Y., Jing, G., & Zhang, C. (2023) · Advanced Intelligent Systems · doi:10.1002/aisy.202200366 · Cited by 2
Artificial intelligence-augmented organ- and organoid-on-a-chip for drug screening
Song, C., Li, T., Guan, H., Zhang, T., Zhu, J., Lei, J., Dong, F., Liu, C., Song, Z., & Huang, L. (2026) · Lab on a Chip · doi:10.1039/d6lc00365f · Cited by 3
Pocock, K. J., Gao, X., Wang, C., Priest, C., Prestidge, C. A., Mawatari, K., Kitamori, T., & Thierry, B. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2202461 · Cited by 1
Nanotechnology and Safety Pharmacology
Polaka, S., Tekade, R. K., & Jain, N. K. (2022) · Springer eBooks · doi:10.1007/978-3-030-73317-9_84-1 · Cited by 1
In Vitro Models and Molecular Markers for Assessing Nano-Based Systems Inflammatory Potential
de Lima, R., Antunes, V. A. N., Germano‐Costa, T., & Casagrande, M. G. (2023) · Interdisciplinary biotechnological advances · doi:10.1007/978-981-19-8342-9_9 · Cited by 1
Risk Assessment of Large-scale Nanoparticle Uses
Akdoğan, O., Bagci, C., Akdogan, N. G., & Ozunlu, S. (2023) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781837670215-00193 · Cited by 1
Organ-on-chip models for pulmonary permeability studies
Lee, D., & Chambers, M. A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15510-9.00018-9 · Cited by 2
Organoid systems for recapitulating the intestinal stem cell niche and modeling disease in vitro
Lim, H. Y. G., Kostic, L., & Barker, N. (2022) · Advances in stem cells and their niches · doi:10.1016/bs.asn.2021.10.001 · Cited by 1
Smith, T. B., Nunzio, A. M. D., Patel, K., Munford, H., Alam, T., Powell, O., Heneghan, N. R., Ready, A. R., Nath, J., & Ludwig, C. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.01.31.929513 · Cited by 1
Intestinal Mucosal Models to Validate Functionalized Nanosystems
Azevedo, C., Pereira, I., & Sarmento, B. F. C. C. (2020) · Wiley eBooks · doi:10.1002/9781119414018.ch7 · Cited by 2
Toxicity of Nanomaterials to the Gastrointestinal Tract
Rice, P. A. (2022) · Wiley eBooks · doi:10.1002/9781119316329.ch12 · Cited by 2
Engineered Liver Platforms for Different Phases of Drug
Khetani, S. R. (2017)
Engineering Organoid Systems to Model Health and Disease
Ankrum, J. A., Bartosh, T. J., Yin, X., Brown, A. J., Burand, A. J., & Boland, L. K. (2017) · Molecular and translational medicine · doi:10.1007/978-3-319-57153-9_10
Szuplewska, A., Chudy, M., & Brzózka, Z. (2017) · Springer eBooks · doi:10.1007/978-3-319-70685-6_4 · Cited by 1
In vitro Models for Testing Toxicity in the Gastrointestinal Tract
Trantakis, I. A. (2018) · Wiley eBooks · doi:10.1002/9781118823309.ch7
McCann, J., & McCann, T. (2016) · Alternatives to Laboratory Animals · doi:10.1177/026119291604400510
“Assay PubMed 2 + 1 and liver tissues suggests that ingested nanoparticles (20) have the potential to cause liver injury.”
Background3D intestinal models towards a more realistic permeability screening
Almeida, A., Azevedo, C., Macedo, M. H., & Sarmento, B. F. C. C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818038-9.00003-x · Cited by 5
Sphabmixay, P. (2020) · DSpace@MIT (Massachusetts Institute of Technology)
The artificial gut : integrating in vitro models of the human digestive tract with mass spectrometry
Santbergen, M. J. C. (2020) · doi:10.18174/532696
Advances In Therapeutic Use of Microfluidics (Body on A Chip): A Review
(2023) · International Journal of Nanotechnology and Nanomedicine · doi:10.33140/ijnn.08.01.07
Oral Delivery of Nanoparticles: Challenges and Opportunities
Lin, Q., Zhang, L., & Zhang, Z. (2023) · Wiley eBooks · doi:10.1002/9781119660699.ch30
Organ-on-chip models for intestinal permeability studies
Carvalho, A. M., & Sarmento, B. F. C. C. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15510-9.00011-6
Nanotechnology and Safety Pharmacology
Polaka, S., Tekade, R. K., & Jain, N. K. (2024) · Springer eBooks · doi:10.1007/978-3-031-35529-5_84 · Cited by 1
Marin, T. M., & Consonni, S. R. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-13403-6.00010-6
Smart Bio-Inspired Structures: Organ-on-Chip
Barzegar, S., Zare, M. R., Rajabi, S., & Ahadian, S. (2025) · Springer eBooks · doi:10.1007/978-3-031-87744-5_10
The Ethics of Medical Research in Surgery
Cinà, C. S. (2025) · Springer eBooks · doi:10.1007/978-3-032-04866-0_15
Modèles de vaisseaux sanguins sur puce pour l'étude des fonctions de la barrière endothéliale
Delannoy, E. (2021) · theses.fr (ABES) · doi:10.70675/c1aab157zdfc1z4179z9306zc6f4d4ffcd6f
Messelmani, T. (2023) · theses.fr (ABES) · doi:10.70675/9a8f7a80zb4ebz4faczb395zff9d3d7ddeac
Hallscheidt, E., Assbrock, L., Hahn, M., Kuehnlenz, J., Thevis, M., & Lamshoeft, M. (2026) · NAM journal. · doi:10.1016/j.namjnl.2026.100095
A Colon Cancer Organoid-on-a-Chip Model for In Vitro Therapy Assessment
Valle, L. G., Ortega, L., Heras, M. F. L., & Holgado, M. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27146427
Fate, toxicology and Organ-on-a-chip methodology of nanoplastics in human body
Wang, Y., Lü, F., Fang, J., Li, G., Zhang, H., & He, P. (2026) · Toxicology · doi:10.1016/j.tox.2026.154550
Николаевич, К. А., Krasnoselskaya, E. N., Khanova, A. R., & Николаевич, Ф. С. (2026) · Biomaterials Advances · doi:10.1016/j.bioadv.2026.215141
In vitro approaches for modelling gut-liver crosstalk in drug-induced liver injury
Janssen, Y., Jiang, J., Vandeputte, D., & Vinken, M. (2026) · Archives of Toxicology · doi:10.1007/s00204-026-04537-2
Liu, W., Lu, Y., & Xu, N. (2026) · Frontiers in Nutrition · doi:10.3389/fnut.2026.1940509
“A body-on-chip study connecting gastrointestinal and liver tissues suggested that ingested polystyrene nanoparticles could produce liver injury not predicted from the gut module alone (4).”
Integrating nanomedicine into microfluidic systems
Vaziri, M., Mahdi, T., Karbalaeimahdi, A., Ghafelehbashi, R., Hoseini, Z. S., Sabet, Z. F., & Taleb, M. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-45538-4.00016-9
Metadata
- Authors
- Esch, M. B., Mahler, G. J., Stokol, T., & Shuler, M. L.
- Affiliations
- Cornell University (US)
- Binghamton University (US)
- Corresponding author
- Shuler, Michael L.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2014
- Volume
- 14
- Issue
- 16
- Pages
- 3081-3092
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- PMC
- PMC4144667
- OpenAlex
- W2030338281
- Cited by
- 281
- References
- 37
- Citations by year
- 2026: 11 · 2025: 24 · 2024: 16 · 2023: 30 · 2022: 20 · 2021: 27 · 2020: 23 · 2019: 28 · 2018: 30 · 2017: 25 · 2016: 31 · 2015: 12 · 2014: 4
- FWCI
- 10.88
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Science Foundation
- National Institutes of Health (UH2TR000516)
- National Center for Advancing Translational Sciences
- U.S. Army Corps of Engineers
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Nanoparticles: synthesis and applications
- Physical Sciences › Materials Science › Biomaterials › Nanoparticle-Based Drug Delivery
- Life Sciences › Immunology and Microbiology › Immunology › Immunotoxicology and immune responses
- Keywords
- body-on-a-chip, organ-on-a-chip, gastrointestinal tract, liver injury, Caco-2/HT29-MTX co-culture, intestinal epithelial barrier, nanoparticle transport, nanoparticle aggregation, nanoparticle toxicity
- MeSH terms
- Analysis of Variance, Cell Line, Cell Survival, Humans, Intestinal Mucosa, Liver, Models, Biological, Toxicity Tests, Cell Culture Techniques, Gastrointestinal Tract, Microfluidic Analytical Techniques, Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.