Lab on a chip for continuous-flow magnetic cell separation
Open accessThe DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Abstract
We review the fundamental physics in continuous-flow magnetic cell separation and identify the optimisation parameters of LOC devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In our microfluidic chip, the drag force and the magnetic force were dominant forces for the magnetic bead-labelled cells (Fig. 1B).”
From Dynamic Halbach array magnet integrated microfluidic system for the continuous-flow separation of rare tumor cells (2019) · cites this paper as [21]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Applications of magnetic nanoparticles in biomedicine
Pankhurst, Q. A., Connolly, J., Jones, S. K., & Dobson, J. (2003) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/36/13/201 · Cited by 5,881
Ghaffari, S., Chandorkar, S. A., Wang, S., Ng, E. J., Ahn, C. H., Hong, V., Yang, Y., & Kenny, T. W. (2014) · Scientific Reports · doi:10.1038/srep04331 · Cited by 1,521
Pamme, N. (2006) · Lab Chip · doi:10.1039/b513005k · Cited by 1,129
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
Continuous flow separations in microfluidic devices
Pamme, N. (2007) · Lab on a Chip · doi:10.1039/b712784g · Cited by 770
Magnetic bead handling on-chip: new opportunities for analytical applications
Gijs, M. A. M. (2004) · Microfluidics and Nanofluidics · doi:10.1007/s10404-004-0010-y · Cited by 749
Microfluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Magnetic nanoparticles: recent advances in synthesis, self-assembly and applications
Singamaneni, S., Bliznyuk, V. N., Binek, C., & Tsymbal, E. Y. (2011) · Journal of Materials Chemistry · doi:10.1039/c1jm11845e · Cited by 537
Continuous separation of cells and particles in microfluidic systems
Lenshof, A., & Laurell, T. (2010) · Chemical Society Reviews · doi:10.1039/b915999c · Cited by 528
Research works printed but not linked: 20
- V. Sahore and I. Fritsch, American Chemical Society, 2013, 85, 11809-11816.
- M. A. M. Gijs, Microfluid Nanofluid, 2004, 1, 22-40.
- J. Berthier, and P. Silberzan, Microfluidics for biotechnology, 2nd edition, 2010, ARTECH HOUSE
- R. Gelszinnis, M. Faivre, J. Degouttes, N. Terrier, R. Ferrigno and A.-L. Deman, 17th International Conference on Miniaturized Systems for Chemistry and Life Sciences 27-31 October 2013, Freiburg, Germany.
- B. Babic, R. Ghai, and K. Dimitrov, Proc. SPIE 6799, BioMEMS and Nanotechnology III, 67990U (December 27, 2007).
- J. Kim, U. Steinfeld, H.-H. Lee and H. Seidel, IEEE SENSORS IEEE SENSORS 2007 Conference, 2007.
- L. Liang, J. Zhu and X. Xuan, BIOMICROFLUIDICS, 2011, 5.
- L. Liang and X. Xuan, Biomicrofluidics, 2012, 6.
- J. Zeng, C. Chen, P. Vedantam, V. Brown, T.-R. J. Tzeng and X. Xuan, J. Micromech. Microeng., 2012, 22.
- H.-K. Seo, Y.-H. Kim, H.-O. Kim and Y.-J. Kim, J. Micromech. Microeng., 2010, 20.
- J. Siegrist, L. Zavattoni, R. Burger and J. Ducrée, Transducers'1111, Beijing, China, June 5-9, 2011.
- H.-K. Seo, H.-O. Kim and Y.-J. Kim, Proceedings of 10th IEEE international conference on nanotechnology joint symposium with nano korea 2010, 911-914.
- K.-H. Han and A. B. Frazier, NSTI-Nanotech 2005, 2005.
- K.-H. Han and A. B. Frazier, JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2005, 14, 1057- 7157.
- O. Yassine, C. P. Gooneratne, D. Abu Smara, F. Li, H. Mohammed, J. Merzaban and J. Kosel, Biomicrofluidics, 2014, 8.
- M. Glynn, D. Kirby, D. Chung, D. J. Kinahan, G. Kijanka and J. Ducrée, Journal of Laboratory Automation, 2013.
- M. Karlel, J. Miwa, G. Roth, R. Zengerle and F. von Stetten, Micro Electro Mechanical Systems, 2009. MEMS 2009. IEEE 22nd International Conference on, 2009.
- M. Mizuno, M. Yamada, R. Mitamura, K. Ike, K. Toyama, M. Seki, Analytical Chemistry, 2013, 85, 7666-7673. · DOI
- A. F. Sousa, J. Loureiro, M. M. Diogo, J. M. S. Cabral and P. P. Freitas, Bioengineering (ENBENG), 2011. ENBENG 2011. 1st Portuguese Meeting in 1-4 March 2011, 2011, 1 -4.
- J. Jung and K.-H. Han, Transducers 2009, Denver, CO, USA, June 21-25, 2009, 2009.
Cited by
Items 201–300 of 346
Vu‐Dinh, H., Feng, H. Z., & Jen, C. (2021) · Biosensors · doi:10.3390/bios11010023 · Cited by 13
“According to Newton’s second law, the equation of force acting on each the target is [31]:”
BackgroundLi, S., Li, Y., Yao, J., Chen, B., Song, J., Xue, Q., & Yang, X. (2021) · Cytometry Part A · doi:10.1002/cyto.a.24475 · Cited by 13
“It is often used to monitor cell proliferation and health status for cultured cells; to in vitro evaluate drug or environmental cytotoxicity effects on target cells; to test the cell viabilities after a series of operations, such as cell separating [4], sorting [5], and capturing [6].”
Application of Chitosan/Fe3O4 Nanocomposite as Biosensor
(2021) · Letters in Applied NanoBioScience · doi:10.33263/lianbs103.24382445 · Cited by 14
Trapping of a Single Microparticle Using AC Dielectrophoresis Forces in a Microfluidic Chip
Wang, Y., Tong, N., Li, F., Zhao, K., Wang, D., Niu, Y., Xu, F., Cheng, J., & Wang, J. (2023) · Micromachines · doi:10.3390/mi14010159 · Cited by 13
“This method has high specificity and is a commonly used method for cell trapping [25,26].”
MethodFar-field theory for trajectories of magnetic ellipsoids in rectangular and circular channels
Matsunaga, D., Zöttl, A., Meng, F., Golestanian, R., & Yeomans, J. M. (2018) · IMA Journal of Applied Mathematics · doi:10.1093/imamat/hxy019 · Cited by 13
Multiple outcome particle manipulation using cascaded surface acoustic waves (CSAW)
Ng, J. W., & Neild, A. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-020-02417-4 · Cited by 14
Artificial Intelligence-Aided Microfluidic Cell Culture Systems
Ibrahim, M. S., & Kim, M. (2025) · Biosensors · doi:10.3390/bios16010016 · Cited by 16
“This precision enables programmed interactions between cells and biomolecules, facilitating applications in cell culturing, organ-on-a-chip systems, disease modeling, and drug testing [56–58].”
Microfluidic shape-based separation for cells and particles: recent progress and future perspective
Khan, M. S., Julio, R. H., Ali, M., Sachs, S., Cierpka, C., König, J., & Park, J. O. (2026) · Lab on a Chip · doi:10.1039/d5lc00826c · Cited by 19
Magnetophoretic Control of Diamagnetic Particles Inside an Evaporating Droplet
Saroj, S. K., & Panigrahi, P. K. (2021) · Langmuir · doi:10.1021/acs.langmuir.1c02968 · Cited by 12
Adel, M., Allam, A., Sayour, A. E., Ragai, H. F., Umezu, S., & El‐Bab, A. M. R. F. (2023) · Micromachines · doi:10.3390/mi14071340 · Cited by 12
“Active sorting methods, such as dielectrophoresis (DEP) [10], magnetophoresis [11], and acoustophoresis [12], utilize externally applied forces to separate cells.”
Method3D Printed Device for Separation of Cells and Particles by Tilted Bulk Acoustic Wave Actuation
Özçelik, A. (2022) · Actuators · doi:10.3390/act11090249 · Cited by 12
Lyu, C., Yang, D., Xu, X., Cai, Y., Liang, B., Zhou, C., Ye, X., & Wang, J. (2025) · Lab on a Chip · doi:10.1039/d5lc00496a · Cited by 11
Tabatabaei, S. A., & Targhi, M. Z. (2021) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119211029753 · Cited by 11
Jiang, Y., Chen, J., Xuan, W., Liang, Y., Huang, X., Cao, Z., Sun, L., Dong, S., & Luo, J. (2023) · Sensors · doi:10.3390/s23052771 · Cited by 11
“Active separation techniques move particles by applying a force inherited from acoustic [3,4], magnetic [5,6], dielectrophoretic [7], or optical [8,9] fields.”
BackgroundSeparation and Washing of Candida Cells from White Blood Cells Using Viscoelastic Microfluidics
Lim, H., Kim, J. Y., Choo, S., Lee, C., Han, B. J., Lim, C. S., & Nam, J. (2023) · Micromachines · doi:10.3390/mi14040712 · Cited by 11
“Active techniques adopt various force fields, including electric [9,10], magnetic [11,12], optical [13], and acoustic forces [14,15], whereas passive techniques utilize the channel geometry and/or hydrodynamic effects of the flow without using external forces [16].”
BackgroundSheridan, E., Vercellino, S., Cursi, L., Adumeau, L., Behan, J. A., & Dawson, K. A. (2021) · Nanoscale Advances · doi:10.1039/d0na01035a · Cited by 11
Isolation of magnetically tagged cancer cells through an integrated magnetofluidic device
Wong, Q. Y., Liu, N., Koh, C.-G., Li, H., & Lew, W. S. (2016) · Microfluidics and Nanofluidics · doi:10.1007/s10404-016-1804-4 · Cited by 10
“…applications for an integrated magnetic Lab-on-Chip (LOC) system which includes cancer cell destruction (Kim et al. 2010), virus detection (Lee et al. 2008), immunoassays (Lim and Zhang 2007), protein analysis (Choi et al. 2002) and cell separation (Hejazian et al. 2015; Inglis et al. 2004).”
Modelling and simulation of particle-particle interaction in a magnetophoretic bio-separation chip
Alam, M., Golozar, M., & Darabi, J. (2018) · Physics of Fluids · doi:10.1063/1.5022582 · Cited by 10
“Magnetic bio-separation has been used in lab-on-a-chip devices, cell separators, micro-total analysis systems, and DNA/RNA isolators [1-11].”
MethodPravinraj, T., & Patrikar, R. M. (2019) · Microelectronic Engineering · doi:10.1016/j.mee.2019.111030 · Cited by 10
Dynamics of a pair of ellipsoidal microparticles under a uniform magnetic field
Zhang, J., Zhou, R., & Wang, C. (2019) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab3432 · Cited by 10
Dissipation-induced rotation of suspended ferromagnetic nanoparticles
Lyutyy, T. V., Denisov, S. I., & Peter Hänggi, A. (2019) · Physical review. B./Physical review. B · doi:10.1103/physrevb.100.134403 · Cited by 10
On-chip analysis of magnetically labeled cells with integrated cell sorting and counting techniques
Zhang, H., Ding, W., Li, S., Ya, S., Li, F., & Qiu, B. (2020) · Talanta · doi:10.1016/j.talanta.2020.121351 · Cited by 10
Kang, B., Han, S., Son, H. Y., Mun, B., Shin, M., Choi, Y., Park, J., Min, J., Park, D., Lim, E., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113576 · Cited by 11
Anisotropic composite polymer for high magnetic force in microfluidic systems
Deman, A., Mekkaoui, S., Dhungana, D. S., Châteaux, J.-F., Tamion, A., Degouttes, J., Dupuis, V., & Roy, D. L. (2017) · Microfluidics and Nanofluidics · doi:10.1007/s10404-017-2008-2 · Cited by 11
Zhang, J., & Nguyen, N. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822532-5.00011-x · Cited by 10
Self-citationChen, X., Gao, Z., Shi, J., Liu, Y., Song, Z., Wu, C., Su, L., Zhang, Z., & Zhao, Y. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.343569 · Cited by 9
Isolation Techniques of Micro/Nano‐Scaled Species for Biomedical Applications
Lu, Q., Zhang, Z., & Ding, X. (2025) · Advanced Science · doi:10.1002/advs.202414109 · Cited by 9
Vortex chip incorporating an orthogonal turn for size-based isolation of circulating cells
Rastogi, N., Seth, P., Bhat, R., & Sen, P. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338423 · Cited by 8
Derakhshan, R., Bozorgzadeh, A., & Ramiar, A. (2023) · Journal of Chromatography A · doi:10.1016/j.chroma.2023.464079 · Cited by 9
NT-proBNP detection with a one-step magnetic lateral flow channel assay
Strohmaier-Nguyen, D., Horn, C., & Baeumner, A. J. (2024) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-024-05223-x · Cited by 9
Portable Battery-Driven Microfluidic Cell Separation Instrument with Multiple Operational Modes
Xiang, N., & Ni, Z. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.2c03833 · Cited by 9
Supervised Learning to Predict Sperm Sorting by Magnetophoresis
Koh, J. B. Y., Shen, X., & Marcos, M. (2018) · Magnetochemistry · doi:10.3390/magnetochemistry4030031 · Cited by 10
“Therefore, the sperm cells may be doped with paramagnetic nanoparticles [16] or sorted in their natural form via diamagnetophoresis [17].”
BackgroundTarn, M. D., Shaw, K. J., Foster, P. B., West, J. S., Johnston, I. D., McCluskey, D., Peyman, S. A., & Murray, B. J. (2025) · Biomicrofluidics · doi:10.1063/5.0236911 · Cited by 12
Meng, Y., Zhang, J., Hong, Z., & Drinkwater, B. W. (2025) · Ultrasonics · doi:10.1016/j.ultras.2025.107647 · Cited by 8
Separation of particles in spiral micro-channel using Dean’s flow fractionation
Mitra, P., Dutta, S., Nagahanumaiah, N., & Hens, A. (2020) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-020-02482-4 · Cited by 8
Hosseini, A., Philpott, D. N., & Soleymani, L. (2017) · Lab on a Chip · doi:10.1039/c7lc00825b · Cited by 8
Microparticle Inertial Focusing in an Asymmetric Curved Microchannel
Özbey, A., Karimzadehkhouei, M., Alijani, H., & Koşar, A. (2018) · Fluids · doi:10.3390/fluids3030057 · Cited by 8
“While the former utilizes external forces [16,17], such as magnetic [18], dielectric [19] or acoustic [20] force, the latter relies on channel geometry and internal forces.”
BackgroundConjugation of Urokinase to Water-Soluble Magnetic Nanoparticles for Enhanced Thrombolysis
Li, Q., Liu, X., Lü, Z., Yang, W., Lei, Z., & Chang, M. (2019) · Applied Sciences · doi:10.3390/app9224862 · Cited by 7
“have gained significant attentions for their applications in magnetic resonance image (MRI) [9,10], cell separation [11,12], and gene therapy [13].”
BackgroundImproved enrichment of circulating tumor cells from diagnostic leukapheresis product
Stevens, M., Mentink, A., Nanou, A., Coumans, F. A. W., Isebia, K. T., Kraan, J., Hamberg, P., Martens, J. W. M., & Terstappen, L. W. M. M. (2023) · Cytometry Part A · doi:10.1002/cyto.a.24779 · Cited by 7
A portable microfluidic device for thermally controlled granular sample manipulation
Zhang, K., Xiang, W., Jia, N., Yu, M., Liu, J., & Xie, Z. (2023) · Lab on a Chip · doi:10.1039/d3lc00888f · Cited by 7
Su, T., Vu‐Dinh, H., Lin, S., Quang, L. D., Duc, T. C., & Jen, C. (2024) · Biomedical Microdevices · doi:10.1007/s10544-023-00689-5 · Cited by 7
“Therefore, the force balance equation is given as (Hejazian et al. 2015): where m p and u p are the mass and velocity of the particles, respectively.”
Lee, G., Song, J., Han, H., Kwon, D., Park, J., Jeon, S., Jeong, S., & Kim, S. (2021) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.1c00256 · Cited by 7
Wang, C., Chen, Y., Gu, X., Zhang, X., Gao, C., Dong, L., Zheng, S., Feng, S., & Xiang, N. (2021) · Electrophoresis · doi:10.1002/elps.202100232 · Cited by 7
Advanced density-based methods for the characterization of materials, binding events, and kinetics
Doan‐Nguyen, T. P., & Crespy, D. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00232e · Cited by 10
Advances in analytical microfluidic workflows for differential cancer diagnosis
Kafshgari, M. H., & Hayden, O. (2022) · Nano Select · doi:10.1002/nano.202200158 · Cited by 7
Rail induced lateral migration of particles across intact co-flowing liquids
Ziemecka, I., de Hemptinne, A., Misko, V. R., Briet, M., Gelin, P., Bihi, I., Maes, D., & Malsche, W. D. (2022) · Scientific Reports · doi:10.1038/s41598-022-26387-5 · Cited by 7
Hafez, A. M., Liu, Q., & Santamarina, J. C. (2023) · Geoenergy Science and Engineering · doi:10.1016/j.geoen.2023.212029 · Cited by 7
Design, modeling, and control of a horizontal magnetic micromanipulator
Ablay, G., Böyük, M., & İçöz, K. (2019) · Transactions of the Institute of Measurement and Control · doi:10.1177/0142331218824392 · Cited by 8
“The gravitational force due to the gravity and buoyancy can be given by (Hejazian et al., 2015)”
BackgroundInfluentialInertia-magnetic particle sorting in microfluidic devices: a numerical parametric investigation
Moghadam, M. C., Eilaghi, A., & Rezai, P. (2019) · Microfluidics and Nanofluidics · doi:10.1007/s10404-019-2301-3 · Cited by 9
Mitra, S., Rahman, M. H., Prince, H. A., & Rozin, E. H. (2020) · IEEE Region 10 Symposium (TENSYMP) · doi:10.1109/tensymp50017.2020.9230654 · Cited by 7
“Brownian force is responsible for the random motion of suspended particles induce from collision with each other depends on the temperature (T), fluid dynamic viscosity (μ), radius of the particle (rp), Kb is the Boltzmann constant, ξ is the Gaussian random number with zero mean and unit variance [8], Δt is the magnit…”
BackgroundZhu, J. F., Chen, T., Chen, C., & Ding, W. D. (2021) · Materials · doi:10.3390/ma14174939 · Cited by 7
Two‐stage particle separation channel based on standing surface acoustic wave
Lv, H., Chen, X., Zhang, Y., Wang, X., Zeng, X., & Zhang, D. (2022) · Journal of Microscopy · doi:10.1111/jmi.13090 · Cited by 7
Flow induced particle separation and collection through linear array pillar microfluidics device
Balyan, P., Saini, D., Das, S., Kumar, D., & Agarwal, A. (2020) · Biomicrofluidics · doi:10.1063/1.5143656 · Cited by 8
Magnetic Separation of Micro Beads and Cells on a Paper-Based Lateral Flow System
Farooqi, M. F., & İçöz, K. (2022) · GAZI UNIVERSITY JOURNAL OF SCIENCE · doi:10.2139/ssrn.4019877 · Cited by 6
Magnetic Microbead-Based Herringbone Chip for Sensitive Detection of Human Immunodeficiency Virus
Tang, M., Yuan, X., Zhu, K.-J., Sun, W., Hong, S.-L., Hu, J., & Liu, K. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.3c04516 · Cited by 6
Yuzhi, 施. S., Chengxing, 赖. L., Weicheng, 夷. Y., Haiyang, 黄. H., Chao, 冯. F., Tao, 何. H., Aiqun, 刘. L., Weicheng, 仇. Q., Zhanshan, 王. W., & Xinbin, 程. C. (2024) · Acta Optica Sinica · doi:10.3788/aos231739 · Cited by 6
Huang, A., Miansari, M., & Friend, J. R. (2018) · Applied Physics Letters · doi:10.1063/1.5037086 · Cited by 6
Diamagnetic repulsion of particles for multilaminar flow assays
Tarn, M. D., Elders, L. T., Peyman, S. A., & Pamme, N. (2015) · RSC Advances · doi:10.1039/c5ra21867e · Cited by 6
Magnetophoresis in Bio-Devices
Deman, A., & Roy, D. L. (2019) · Microtechnology and MEMS · doi:10.1007/978-981-13-6549-2_7 · Cited by 8
Nanosensors-Assisted Quantitative Analysis of Biochemical Processes in Droplets
Belyaev, D., Schütt, J., Ibarlucea, B., Rim, T., Baraban, L., & Cuniberti, G. (2020) · Micromachines · doi:10.3390/mi11020138 · Cited by 7
Sampling and Mass Detection of a Countable Number of Microparticles Using on-Cantilever Imprinting
Nyang’au, W. O., Setiono, A., Schmidt, A., Bosse, H., & Peiner, E. (2020) · Sensors · doi:10.3390/s20092508 · Cited by 6
“) [27], and separating and sorting of cells [28].”
BackgroundZhang, W.-G., Liu, Z.-Y., & Pang, S. (2020) · Engineering · doi:10.1016/j.eng.2020.09.010 · Cited by 7
Multi-Particle sorting using signals from particles trapped by single optical fiber tweezers
Yao, L., Wang, T., Jiang, C., Zhao, Q., Sui, Y., Yan, L., Wang, Y., Sun, Y. W., Cong, Z., & Dong, T. (2024) · Optical Fiber Technology · doi:10.1016/j.yofte.2024.103994 · Cited by 7
Oladokun, R., Srivastava, S. K., Schiele, N. R., & Pei, M. (2024) · Physics of Fluids · doi:10.1063/5.0237188 · Cited by 6
Continuous Flow Separation of Live and Dead Cells Using Gravity Sedimentation
Özçelik, A., Güçlüer, S., & Keskin, T. (2023) · Micromachines · doi:10.3390/mi14081570 · Cited by 5
“During the sorting process, the labeled cells flow through microfluidic channels, where they encounter optical or magnetic forces [24].”
BackgroundLyu, C., Jiang, Y. P., Dai, Z., Xu, X., Cai, Y., Liang, B., Zhou, C., Ye, X., & Wang, J. (2024) · Magnetochemistry · doi:10.3390/magnetochemistry10100075 · Cited by 5
Effect of geometry on dielectrophoretic trap stiffness in microparticle trapping
Rahman, M. R. U., Kwak, T. J., Woehl, J. C., & Chang, W.-J. (2021) · Biomedical Microdevices · doi:10.1007/s10544-021-00570-3 · Cited by 6
I-LIFT (image-based laser-induced forward transfer) platform for manipulating encoded microparticles
Lee, S., Lee, W., Lee, A. C., Nam, J., Lee, J., Kim, H., Jeong, Y., Yeom, H., Kim, N., Song, S. W., et al. (2022) · Biomicrofluidics · doi:10.1063/5.0131733 · Cited by 5
Pandit, P., Kong, L., & Samuel, G. L. (2024) · RSC Advances · doi:10.1039/d3ra06431j · Cited by 5
Biochemical Analysis Techniques Integrated on Microfluidic Chips and Their Applications
Wu, J., & Lin, J. (2017) · Integrated analytical systems · doi:10.1007/978-981-10-5394-8_10 · Cited by 5
Triplex Inertia-Magneto-Elastic (TIME) sorting of microparticles in non-Newtonian fluids
Dibaji, S., & Rezai, P. (2020) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2020.166620 · Cited by 5
Microfluidic Systems for Isolation of White Blood Cells: From Design to Practical Applications
Mane, S., Puri, D. B., Hemadri, V. A., Bhand, S., & Tripathi, S. (2025) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2025.2514795 · Cited by 4
“[42,43] For example, microfiltration devices have been used to isolate circulating tumor cells (CTCs) from whole blood based on size differences, such as in the CellSieve TM microfiltration platform.”
Ahmed, M., Mohamed, A., & Taha, E. (2015) · International Journal of Computer Applications · doi:10.5120/ijca2015906978 · Cited by 4
“The separation of particles is important for many biological and biomedical applications including cell biology, diagnostics, and therapeutics, especially in cancer cell detection, drug screening, and tissue engineering [1-3].”
BackgroundLee, S., Jeong, M.-S., Lee, S., Lee, S. H., & Choi, J. (2021) · Nanoscale Advances · doi:10.1039/d1na00791b · Cited by 4
Hou, S., Zhao, L., Yu, J., Wang, Z., Duan, J., & Zhang, B. (2024) · Physica Scripta · doi:10.1088/1402-4896/ad7236 · Cited by 4
Sorting spermatozoa by morphology using magnetophoresis
Koh, J. B. Y., & Marcos, M. (2017) · Microfluidics and Nanofluidics · doi:10.1007/s10404-017-1911-x · Cited by 4
Kabir, M. N. (2019) · Palgrave Macmillan US eBooks · doi:10.1057/978-1-137-34809-8_4 · Cited by 6
Feedback controller designs for an electromagnetic micromanipulator
Böyük, M., Eroğlu, Y., Ablay, G., & İçöz, K. (2019) · Proceedings of the Institution of Mechanical Engineers Part I Journal of Systems and Control Engineering · doi:10.1177/0959651819871783 · Cited by 5
Ghadiri, M. M., Hosseini, S. A., Sadatsakkak, S. A., & Rajabpour, A. (2021) · Biomedical Microdevices · doi:10.1007/s10544-021-00577-w · Cited by 4
Cell density detection based on a microfluidic chip with two electrode pairs
Wang, Y., Chen, D., & Guo, X. (2022) · Biotechnology Letters · doi:10.1007/s10529-022-03294-3 · Cited by 4
Hui, G., Ao, T., Liu, H., Li, M., & Chen, C. (2024) · Micromachines · doi:10.3390/mi16010003 · Cited by 3
Microfluidic Technology for Single-Cell Capture and Isolation
Wu, J., & Lin, J. (2019) · Integrated analytical systems · doi:10.1007/978-981-32-9729-6_2 · Cited by 3
Gao, W., Tao, W., & Zhao, H. Z. (2016) · Communications in computer and information science · doi:10.1007/978-981-10-2672-0_17 · Cited by 3
Development of an optimized dome-shaped magnet for rapid magnetic immunostaining
Sekino, M., Kuwahata, A., Fujita, S., Matsuda, S., Kaneko, M., Chikaki, S., Sakamoto, S., Saito, I., Handa, H., & Kusakabe, M. (2020) · AIP Advances · doi:10.1063/1.5130516 · Cited by 3
In-Silico Conceptualisation of Continuous Millifluidic Separators for Magnetic Nanoparticles
Wen, Y., Jiang, D., Gavriilidis, A., & Besenhard, M. O. (2021) · Materials · doi:10.3390/ma14216635 · Cited by 3
“The design rules for LGMS, however, are less clear and more theoretical and experimental work must be dedicated to realise its true potential [18].”
BackgroundInversion Algorithm of Fiber Bragg Grating for Nanofluid Flooding Monitoring
Yahya, N., Nyuk, C. M., Ismail, A. F., Hussain, N., Rostami, A., Ismail, A., Ganeson, M., & Halage, A. A. (2020) · Sensors · doi:10.3390/s20041014 · Cited by 3
Iiguni, Y., Tanaka, A., Kitagawa, S., & Ohtani, H. (2016) · Analytical Sciences · doi:10.2116/analsci.32.41 · Cited by 3
Multifunctional Magnetic Nanoparticles for Theranostic Applications
Tudisco, C., Cambria, M. T., & Condorelli, G. G. (2018) · Elsevier eBooks · doi:10.1016/b978-0-323-50878-0.00012-4 · Cited by 3
Magnetic microparticle concentration and collection using a mechatronic magnetic ratcheting system
Adeyiga, O. B., Murray, C., Munoz, H. E., Escobar, A. R., & Carlo, D. D. (2021) · PLoS ONE · doi:10.1371/journal.pone.0246124 · Cited by 3
Spot Immunomagnetic Enrichment Device for Rapid Detection of Pathogens in Peripheral Blood
Singh, S. K., Upadhyay, M., Pandey, V., Vivekanandan, P., Gupta, S., & Elangovan, R. (2016) · Advanced Materials Technologies · doi:10.1002/admt.201600101 · Cited by 2
Selective Manipulation and Trapping of Magnetically Barcoded Materials
Hajiaghajani, A., Escobar, A. R., Dautta, M., & Tseng, P. (2019) · Advanced Materials Interfaces · doi:10.1002/admi.201901312 · Cited by 2
Model-Free Controller Designs for a Magnetic Micromanipulator
Ablay, G. (2020) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.4048489 · Cited by 2
Micro/Nano-Chip Electrokinetics
Xuan, X. S., & Qian, S. (2017) · MDPI eBooks · doi:10.3390/books978-3-03842-453-6 · Cited by 2
Experimental Study of the Deposition of Magnetic Particles on the Walls of Microchannels
Varela, S., Rivas, A., Vernet, A., & Pallarès, J. (2021) · Micromachines · doi:10.3390/mi12060712 · Cited by 3
Taherkhani, G., Tabesh, H., Amoabediny, G., Torabi, E., Aroon, M. A., Fathipour, M., Ebadi, A. A., Khodarahmi, M., & Miri, M. (2022) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2022.169838 · Cited by 2
Simulation of an hybrid blood cells micro-separator
Aissa, F., Rahim, R. A., Nordin, A. N., & Ibrahim, S. N. (2015) · IEEE Regional Symposium on Micro and Nanoelectronics · doi:10.1109/rsm.2015.7354955 · Cited by 2
Particle migration in viscoelastic microfluidics
Yuan, D. (2018) · Research Online (University of Wollongong) · Cited by 2
Norouzy, N., Nikdoost, A., & Rezai, P. (2024) · Micromachines · doi:10.3390/mi15101228 · Cited by 1
“Active methods utilize external sources of energy, such as dielectrophoresis [13–15], acoustophoresis [16–18], or magnetophoresis [19–21], to manipulate particles.”
MethodShi, J., Chen, X., Ke, F., Bai, Z., Liu, H., Zhu, H., Li, X., Li, L., & Zhao, Y. (2025) · Soft Matter · doi:10.1039/d5sm01012h · Cited by 1
Size effects in magnetic separation for rapid and efficient bacteria removal
Chen, J., Chandler, A. M., Külaots, I., Zhang, Q., & Colvin, V. L. (2026) · Nanoscale · doi:10.1039/d5nr03699b · Cited by 2
Metadata
- Authors
- Hejazian, M., Li, W., & Nguyen, N.-T.
- Affiliations
- Griffith University (AU)
- University of Wollongong (AU)
- Corresponding author
- Nguyen, Nam-Trung
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 15
- Issue
- 4
- Pages
- 959-970
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2152719918
- Cited by
- 347
- References
- 70
- Citations by year
- 2026: 16 · 2025: 14 · 2024: 15 · 2023: 24 · 2022: 30 · 2021: 42 · 2020: 35 · 2019: 47 · 2018: 44 · 2017: 28 · 2016: 40 · 2015: 12
- FWCI
- 2.28
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Lab on a Chip (publishedVersion)
- PubMed (publishedVersion)
- Research Online (University of Wollongong) (submittedVersion)
- Griffith Research Online (submittedVersion)
- Funders
- Griffith University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrowetting and Microfluidic Technologies
- Keywords
- magnetic cell separation, continuous-flow microfluidics, magnetic force, particle separation, microfluidic device design, biocompatibility
- MeSH terms
- Cell Separation, Humans, Lab-On-A-Chip Devices, Magnetic Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.