CoChat

Infection and immunity on a chip: a compartmentalised microfluidic platform to monitor immune cell behaviour in real time

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Immunity on a chip: modeling and designing immune reactions in vitro to study immune responses on a chip as well as unraveling physiological processes under a microscope.

Overview

Integrity signals

Registry

Crossref · 10.1039/c4lc01438c

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 9

  1. Xu, 2011, J. Visualized Exp., 55, e3296
  2. Zigmond, 1977, J. Cell Biol., 75
  3. Muinonen-Martin, 2010, PLoS One, 5
  4. Whitesides, 2006, Nature, 442
  5. Wu, 2013, Lab Chip, 13
  6. Choi, 2010, Biomicrofluidics, 4
  7. Qin, 2010, Nat. Protoc., 5
  8. Ngalim, 2010, J. Oncol., 2010
  9. Faure-Andre, 2008, Science, 322

Cited by

See all 43

Metadata

Authors
Gopalakrishnan, N., Hannam, R., Casoni, G. P., Barriet, D., Ribe, J. M., Haug, M., & Halaas, Ø.
Affiliations
  • National Taiwan Normal University (TW)
  • Norwegian University of Science and Technology (NO)
Corresponding author
Halaas, Ø.
Venue
Lab on a Chip
Published
2015
Volume
15
Issue
6
Pages
1481-1487
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W1988335393
Cited by
42
References
24
Citations by year
2026: 2 · 2025: 1 · 2023: 7 · 2022: 4 · 2021: 4 · 2020: 7 · 2019: 4 · 2018: 4 · 2017: 2 · 2016: 6 · 2015: 1
FWCI
2.16
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
Funders
Norges Forskningsråd
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
Keywords
leukocyte migration, cell homing, real-time cell monitoring, bacterial infection, bacterial filters, immune cell recruitment, infection and immunity
MeSH terms
Cell Line, Cell Movement, Chemotaxis, Diffusion, Lymphocytes, Mycobacterium avium, Tuberculosis, Coculture Techniques, Microfluidic Analytical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.