CoChat

A convection-driven long-range linear gradient generator with dynamic control

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

We developed a novel gradient generator to achieve long range and linear chemical gradients with a dynamic control function.

Overview

Integrity signals

Registry

Crossref · 10.1039/c4lc01451k

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 33 references

Research works printed but not linked: 1

  1. Hung, 2005, Biotechnol. Bioeng., 89

Cited by

Metadata

Authors
Wang, H., Chen, C.-H., Xiang, Z., Wang, M., & Lee, C.
Affiliations
National University of Singapore (SG)
Corresponding author
  • Chen, Chia-Hung
  • Lee, Chengkuo
Venue
Lab on a Chip
Published
2015
Volume
15
Issue
6
Pages
1445-1450
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2096130817
Cited by
40
References
33
Citations by year
2026: 1 · 2025: 6 · 2024: 2 · 2023: 1 · 2022: 3 · 2021: 4 · 2020: 5 · 2019: 3 · 2018: 3 · 2017: 2 · 2016: 8 · 2015: 2
FWCI
2.48
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
  • National University of Singapore (submittedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
Keywords
chemical gradients, linear gradient, dynamic flow control, shear stress, drug screening, PC9 cells, cell viability
MeSH terms
Cell Survival, Equipment Design, Humans, Convection, Cell Line, Tumor, Microfluidic Analytical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.