The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Room-temperature high-performance acetone gas sensor based on hydrothermal synthesized SnO2-reduced graphene oxide hybrid composite
Abstract
In this paper, we demonstrated a room-temperature acetone gas sensor based on a tin dioxide (SnO 2)-reduced graphene oxide (RGO) hybrid composite film.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geim, A. K., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1849 · Cited by 39,979
Measurement of the Elastic Properties and Intrinsic Strength of Monolayer Graphene
Lee, C., Wei, X., Kysar, J. W., & Hone, J. (2008) · Science · doi:10.1126/science.1157996 · Cited by 20,847
Large-Area Synthesis of High-Quality and Uniform Graphene Films on Copper Foils
Li, X., Cai, W., An, J., Kim, S., Nah, J., Yang, D., Piner, R., Velamakanni, A., Jung, I., Tutuc, E., et al. (2009) · Science · doi:10.1126/science.1171245 · Cited by 11,220
Graphene-Based Ultracapacitors
Stoller, M. D., Park, S., Zhu, Y., An, J., & Ruoff, R. S. (2008) · Nano Letters · doi:10.1021/nl802558y · Cited by 8,373
Detection of individual gas molecules adsorbed on graphene
Schedin, F., Geim, A. K., Morozov, S. V., Hill, E. W., Blake, P., Katsnelson, M. I., & Novoselov, K. S. (2007) · Nature Materials · doi:10.1038/nmat1967 · Cited by 8,028
Chemical methods for the production of graphenes
Park, S., & Ruoff, R. S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.58 · Cited by 6,663
Highly sensitive and selective gas sensors using p-type oxide semiconductors: Overview
Kim, H.-J., & Lee, J.-H. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.11.005 · Cited by 2,258
Controllable N-Doping of Graphene
Guo, B., Liu, Q., Chen, E., Zhu, H., Fang, L., & Gong, J. R. (2010) · Nano Letters · doi:10.1021/nl103079j · Cited by 854
Reduced graphene oxide for room-temperature gas sensors
Lu, G., Ocola, L. E., & Chen, J. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/44/445502 · Cited by 775
Carbon dioxide gas sensor using a graphene sheet
Yoon, H. J., Jun, D. H., Yang, J. H., Zhou, Z., Yang, S. S., & Cheng, M. M.-C. (2011) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2011.03.035 · Cited by 714
Highly sensitive NO2 gas sensor based on ozone treated graphene
Chung, M. G., Kim, D. H., Lee, H. M., Kim, T., Choi, J. H., Seo, D. K., Yoo, J.-B., Hong, S.-H., Kang, T. J., & Kim, Y. H. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.02.036 · Cited by 356
Epitaxially grown graphene based gas sensors for ultra sensitive NO2 detection
Pearce, R., Iakimov, T., Andersson, M., Hultman, L., Spetz, A. L., & Yakimova, R. (2011) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.12.046 · Cited by 343
Liu, M., Gan, L., Xiong, W., Xu, Z., Zhu, D., & Chen, L. (2014) · J. Mater. Chem. A · doi:10.1039/c3ta14445c · Cited by 316
Song, H., Zhang, L., He, C., Qu, Y., Tian, Y., & Lv, Y. (2011) · Journal of Materials Chemistry · doi:10.1039/c0jm04331a · Cited by 307
Russo, P. A., Donato, N., Leonardi, S. G., Baek, S., Conte, D. E., Neri, G., & Pinna, N. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201204373 · Cited by 282
Lin, Q., Li, Y., & Yang, M. (2012) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2012.06.055 · Cited by 234
Choi, S.-J., Fuchs, F., Demadrille, R., Grévin, B., Jang, B.-H., Lee, S.-J., Lee, J.-H., Tuller, H. L., & Kim, I.-D. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am501394r · Cited by 183
Xiao, T., Wang, X.-Y., Zhao, Z.-H., Li, L., Zhang, L., Yao, H.-C., Wang, J.-S., & Li, Z.-J. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.04.015 · Cited by 181
Acetone gas sensors based on graphene-ZnFe2O4 composite prepared by solvothermal method
Liu, F., Chu, X., Dong, Y., Zhang, W., Sun, W., & Shen, L. (2013) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2013.06.065 · Cited by 172
NO2and humidity sensing characteristics of few-layer graphenes
Ghosh, A., Late, D. J., Panchakarla, L. S., Govindaraj, A., & Rao, C. N. R. (2009) · Journal of Experimental Nanoscience · doi:10.1080/17458080903115379 · Cited by 163
Cheng, L., Ma, S. Y., Li, X. B., Luo, J. L., Li, W. Q., Li, F., Mao, Y. Z., Wang, T. T., & Li, Y. F. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.04.063 · Cited by 154
Wang, X., Cui, F., Lin, J., Ding, B., Yu, J., & Al‐Deyab, S. S. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.05.050 · Cited by 150
The sensing mechanism and detection of low concentration acetone using chitosan-based sensors
Nasution, T. I., Nainggolan, I., Hutagalung, S. D., Ahmad, K. R., & Ahmad, Z. A. (2012) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2012.11.063 · Cited by 132
Nanocrystalline Ce doped CoFe2O4 as an acetone gas sensor
Khandekar, M. S., Tarwal, N. L., Mulla, I. S., & Suryavanshi, S. S. (2013) · Ceramics International · doi:10.1016/j.ceramint.2013.06.021 · Cited by 95
Ding, M., Sorescu, D. C., & Star, A. (2013) · Journal of the American Chemical Society · doi:10.1021/ja402887v · Cited by 93
High performance of nanostructured ZnO film gas sensor at room temperature
Shao, C., Chang, Y., & Long, Y. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.08.003 · Cited by 86
Synthesis of defect graphene and its application for room temperature humidity sensing
Huang, Q., Zeng, D., Tian, S., & Xie, C. (2012) · Materials Letters · doi:10.1016/j.matlet.2012.05.074 · Cited by 78
Sn O 2 thick films for room temperature gas sensing applications
Khun, K. K., Mahajan, A., & Bedi, R. K. (2009) · Journal of Applied Physics · doi:10.1063/1.3273323 · Cited by 77
Rentenberger, R., Cayla, A., Villmow, T., Jehnichen, D., Campagne, C., Rochery, M., Devaux, É., & Pötschke, P. (2011) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2011.07.004 · Cited by 36
Breath Acetone Analysis of Diabetic Dogs Using a Cavity Ringdown Breath Analyzer
Wang, Z., Wang, C., & Lathan, P. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2293705 · Cited by 17
Cited by
Nanostructured Materials for Room‐Temperature Gas Sensors
Zhang, J., Liu, X., Neri, G., & Pinna, N. (2016) · Advanced Materials · doi:10.1002/adma.201503825 · Cited by 1,569
Recent advances in graphene based gas sensors
Varghese, S. S., Lonkar, S., Singh, K. K., Swaminathan, S., & Abdala, A. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.04.062 · Cited by 890
Li, Z., Li, H., Wu, Z., Wang, M., Luo, J., Torun, H., Hu, P., Yang, C., Grundmann, M., Liu, X., et al. (2019) · Materials Horizons · doi:10.1039/c8mh01365a · Cited by 760
Joshi, N., Hayasaka, T., Liu, Y., Liu, H., Oliveira, O. N., & Lin, L. (2018) · Microchimica Acta · doi:10.1007/s00604-018-2750-5 · Cited by 753
Graphene–metal oxide nanohybrids for toxic gas sensor: A review
Gupta Chatterjee, S., Chatterjee, S., Ray, A. K., & Chakraborty, A. K. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.070 · Cited by 737
Metadata
- Authors
- Zhang, D., Liu, A., Chang, H., & Xia, B.
- Venue
- RSC Advances
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 5
- Issue
- 4
- Pages
- 3016-3022
- ISSN
- 2046-2069 (ISSN-L)
- OpenAlex
- W2014767715
- Cited by
- 287
- References
- 30
- FWCI
- 12.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.