The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A TICT based NIR-fluorescent probe for human serum albumin: a pre-clinical diagnosis in blood serum
Abstract
A TICT based NIR-fluorescent probe 3 has been designed and synthesized which selectively detects HSA with fluorescence enhancement in blood plasma with a detection limit of 11 nM among the various proteins, nucleotides and thiols tested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grabowski, Z. R., Rotkiewicz, K., & Rettig, W. (2003) · Chemical Reviews · doi:10.1021/cr940745l · Cited by 3,714
Specific light-up bioprobes based on AIEgen conjugates
Liang, J., Tang, B. Z., & Liu, B. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00444b · Cited by 762
Cited by
Recent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
A high quantum yield molecule-protein complex fluorophore for near-infrared II imaging
Antaris, A. L., Chen, H., Diao, S., Ma, Z., Zhang, Z., Zhu, S., Wang, J., Lozano, A. X., Fan, Q., Chew, L., et al. (2017) · Nature Communications · doi:10.1038/ncomms15269 · Cited by 623
Nguyen, V.-N., Qi, S., Kim, S., Kwon, N., Kim, G., Yim, Y., Park, S., & Yoon, J. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b09220 · Cited by 457
Niu, H., Liu, J., O’Connor, H. M., Gunnlaugsson, T., James, T. D., & Zhang, H. (2023) · Chemical Society Reviews · doi:10.1039/d1cs01097b · Cited by 449
Design and Application of Fluorescent Probes to Detect Cellular Physical Microenvironments
Ma, J., Sun, R., Xia, K., Xia, Q., Liu, Y., & Zhang, X. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00573 · Cited by 408
Metadata
- Authors
- Reja, S. I., Khan, I. A., Bhalla, V., & Kumar, M.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2016
- Volume
- 52
- Issue
- 6
- Pages
- 1182-1185
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2167237931
- Cited by
- 171
- References
- 2
- FWCI
- 7.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.