Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 93 of the 97 references it cites were found in a registry or an index.

Review of multidimensional data processing approaches for Raman and infrared spectroscopy

Open access
Gautam, Rekha, Vanga, Sandeep, Ariese, Freek, Umapathy, Siva · 2015 · EPJ Techniques and Instrumentation

Abstract

Raman and Infrared (IR) spectroscopies provide information about the structure, functional groups and environment of the molecules in the sample. In combination with a microscope, these techniques can also be used to study molecular distributions in heterogeneous samples. Over the past few decades Raman and IR microspectroscopy based techniques have been extensively used to understand fundamental biology and responses of living systems under diverse physiological and pathological conditions. The spectra from biological systems are complex and diverse, owing to their heterogeneous nature consisting of bio-molecules such as proteins, lipids, nucleic acids, carbohydrates etc. Sometimes minor differences may contain critical information. Therefore, interpretation of the results obtained from Raman and IR spectroscopy is difficult and to overcome these intricacies and for deeper insight we need to employ various data mining methods. These methods must be suitable for handling large multidimensional data sets and for exploring the complete spectral information simultaneously. The effective implementation of these multivariate data analysis methods requires the pretreatment of data. The preprocessing of raw data helps in the elimination of noise (unwanted signals) and the enhancement of discriminating features. This review provides an outline of the state-of-the-art data processing tools for multivariate analysis and the various preprocessing methods that are widely used in Raman and IR spectroscopy including imaging for better qualitative and quantitative analysis of biological samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1140/epjti/s40485-015-0018-6

Cites

93 of 93 references verified0 citation errors · 0 not checkable

Statistics

Figures

Image 1
CC-BY · From the PDF
Fig. 1 Scatter Plots of score values of different Principal Components (PCs). Each point in the scatter plot represents a Raman spectrum, recorded from Drosophila muscles at 785 nm excitation wavelength. Score values corresponding to retained spectra are marked in black, and score values of outliers are marked in other colors. The first row indicates PC1 through PC6 and similarly the first column indicates PC1 through PC6. Score values of outliers are far apart from the other score values in each scatter plot
Fig. 1 Scatter Plots of score values of different Principal Components (PCs). Each point in the scatter plot represents a Raman spectrum, recorded from Drosophila muscles at 785 nm excitation wavelength. Score values corresponding to retained spectra are marked in black, and score values of outliers are marked in other colors. The first row indicates PC1 through PC6 and similarly the first column indicates PC1 through PC6. Score values of outliers are far apart from the other score values in each scatter plotCC-BY · From the PDF
Fig. 2 Principal Component Scores of raw and preprocessed FTIR images of mouse liver exposed to acetaminophen. The rows represent control, 0.5 h, 3 h and 6 h images respectively. The first three columns represent PC1, PC2, PC3 score images of the raw FTIR spectra. The last three columns represent PC1, PC2, PC3 score images of the preprocessed FTIR spectra. Dark blue regions in the preprocessed images (4 th , 5 th and 6 th columns) indicate the presence of glass substrate. Uniformity within the same image and differentiation capability across different time points is enhanced by preprocessing the data
Fig. 2 Principal Component Scores of raw and preprocessed FTIR images of mouse liver exposed to acetaminophen. The rows represent control, 0.5 h, 3 h and 6 h images respectively. The first three columns represent PC1, PC2, PC3 score images of the raw FTIR spectra. The last three columns represent PC1, PC2, PC3 score images of the preprocessed FTIR spectra. Dark blue regions in the preprocessed images (4 th , 5 th and 6 th columns) indicate the presence of glass substrate. Uniformity within the same image and differentiation capability across different time points is enhanced by preprocessing the dataCC-BY · From the PDF
Image 4
CC-BY · From the PDF
Fig. 4 a Raw and b preprocessed Raman spectra of muscles from control Canton-S (CS) 2 days old flies. The dark shaded areas correspond with the average Raman intensity +/ -one standard deviation. The differentiating Raman features are enhanced by preprocessing the data, which reduces the variability among the spectra from the same group
Fig. 4 a Raw and b preprocessed Raman spectra of muscles from control Canton-S (CS) 2 days old flies. The dark shaded areas correspond with the average Raman intensity +/ -one standard deviation. The differentiating Raman features are enhanced by preprocessing the data, which reduces the variability among the spectra from the same groupCC-BY · From the PDF
Image 6
CC-BY · From the PDF
Fig. 6 Schematic representation of an ANN, in this case with a single hidden layer. The data flow from input layer to output layer via the hidden layer(s). Black arrows represent the connections between the artificial nodes and each node is connected to all other nodes in the adjacent layers
Fig. 6 Schematic representation of an ANN, in this case with a single hidden layer. The data flow from input layer to output layer via the hidden layer(s). Black arrows represent the connections between the artificial nodes and each node is connected to all other nodes in the adjacent layersCC-BY · From the PDF
Fig. 7 Schematic representation of Support Vector Machine (SVM), identifying the optimal hyperplane for a two-class data set
Fig. 7 Schematic representation of Support Vector Machine (SVM), identifying the optimal hyperplane for a two-class data setCC-BY · From the PDF
Fig. 8 Hierarchical Cluster Analysis of Raman image from a HeLa cell, the most commonly used human (cervical cancer) cell line. a White-light image; b corresponding Raman image of four clusters obtained by using AHCA multivariate technique; black regions indicate low SNR spectra (mostly buffer and substrate), which were removed prior to AHCA during the preprocessing stage; c average Raman spectra of four clusters; and d the difference spectrum (black) obtained by subtracting the average spectrum of the purple region from the average spectrum of the green region
Fig. 8 Hierarchical Cluster Analysis of Raman image from a HeLa cell, the most commonly used human (cervical cancer) cell line. a White-light image; b corresponding Raman image of four clusters obtained by using AHCA multivariate technique; black regions indicate low SNR spectra (mostly buffer and substrate), which were removed prior to AHCA during the preprocessing stage; c average Raman spectra of four clusters; and d the difference spectrum (black) obtained by subtracting the average spectrum of the purple region from the average spectrum of the green regionCC-BY · From the PDF
Image 10
CC-BY · From the PDF

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 97 references

Research works printed but not linked: 5

  1. Gautam R, Samuel A, Sil S, Chaturvedi D, Dutta A, et al. Raman and Infrared Imaging: Applications and Advancements. Curr Sci. 2015;108:341–56.
  2. Esbensen KH. Multivariate Data Analysis-in practice, 5th Edition. CAMO; 2000.
  3. Srinivasan GK. Vibrational Spectroscopic Imaging for Biomedical Applications, first edition. McGraw-Hill Professional; 2010.
  4. Eilers PHC. Boelens HFM. Baseline correction with asymmetric least squares smoothing: Leiden University Medical Centre Report; 2005.
  5. Bhargava R. Levin IW. Wiley-Blackwell: Spectroscopic Analysis using Infrared Multichannel Detectors; 2005.

Cited by

See all 735

Metadata

Authors
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S.
Affiliations
Indian Institute of Science Bangalore (IN)
Venue
EPJ Techniques and Instrumentation
Published
2015-06-02
Volume
2
Issue
1
ISSN
2195-7045 (ISSN-L)
OpenAlex
W1563946068
Cited by
696
References
97
Citations by year
2026: 53 · 2025: 88 · 2024: 91 · 2023: 65 · 2022: 99 · 2021: 89 · 2020: 79 · 2019: 45 · 2018: 39 · 2017: 33 · 2016: 13 · 2015: 2
FWCI
17.55
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • EPJ Techniques and Instrumentation (publishedVersion, cc-by)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
Funders
  • Indian Institute of Science
  • Department of Biotechnology, Ministry of Science and Technology, India
  • Department of Science and Technology, Ministry of Science and Technology, India
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Chemistry › Analytical Chemistry › Spectroscopy and Chemometric Analyses
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
Raman spectroscopy, infrared spectroscopy, Raman imaging, infrared imaging, multivariate analysis, spectral preprocessing, biological specimen, spectral interpretation, noise reduction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Review of multidimensional data processing approaches for Raman and infrared spectroscopy. https://app.cochat.ai/papers/10.1140/epjti/s40485-015-0018-6
The paper
Gautam, R., Vanga, S., Ariese, F., & Umapathy, S. (2015). Review of multidimensional data processing approaches for Raman and infrared spectroscopy. EPJ Techniques and Instrumentation. https://doi.org/10.1140/epjti/s40485-015-0018-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.