Quaternised chitosan coating on titanium provides a self-protective surface that prevents bacterial colonisation and implant-associated infections
The DOI matches its Crossref record; 50 of the 50 references it cites were found in a registry or an index.
Abstract
The Ti rod-treated group showed radiographic signs of osseous destruction, osteolytic lesions and consecutive deformity after 14 days, while the HTi rod-treated group were free of radiographic signs of infection.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The quaternized chitosan derivative may also be immobilized on titanium implant surfaces via silanization with aminopropyltriethoxysilane [215].”
From Quaternary ammonium-based biomedical materials: State-of-the-art, toxicological aspects and antimicrobial resistance (2017) · cites this paper as [215]
In the citing paper
“Incorporation of silyl groups enables covalent attachment of the quaternized chitosan derivative on the metal or hydroxylated surfaces, while the QA group exerts long-term antibacterial activity.”
From Quaternary ammonium-based biomedical materials: State-of-the-art, toxicological aspects and antimicrobial resistance (2017) · cites this paper as [215]
In the citing paper
“Titanium surfaces modified with HACC prevent bacteria attachment in vitro and reduce infection in vivo. The coated titanium implants are well-integrated with the surrounding bone without bacterial growth.”
From Quaternary ammonium-based biomedical materials: State-of-the-art, toxicological aspects and antimicrobial resistance (2017) · cites this paper as [215]
Citations
Cites
Antibiotic resistance-the need for global solutions
Laxminarayan, R., Duse, A., Wattal, C., Zaidi, A. K. M., Wertheim, H. F. L., Sumpradit, N., Vlieghe, E., Hara, G. L., Gould, I. M., Goossens, H., et al. (2013) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(13)70318-9 · Cited by 4,439
Cytotoxicity and Genotoxicity of Silver Nanoparticles in Human Cells
AshaRani, P. V., Low Kah Mun, G., Hande, M. P., & Valiyaveettil, S. (2009) · ACS Nano · doi:10.1021/nn800596w · Cited by 3,692
Biomaterial-Centered Infection: Microbial Adhesion Versus Tissue Integration
Gristina, A. G. (1987) · Science · doi:10.1126/science.3629258 · Cited by 2,156
Chitosan: A versatile biopolymer for orthopaedic tissue-engineering
Di Martino, A., Sittinger, M., & Risbud, M. V. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.03.016 · Cited by 1,634
Novel chitin and chitosan nanofibers in biomedical applications
Jayakumar, R., Prabaharan, M., Nair, S. V., & Tamura, H. (2010) · Biotechnology Advances · doi:10.1016/j.biotechadv.2009.11.001 · Cited by 1,013
Antibacterial coatings on titanium implants
Zhao, L., Chu, P. K., Zhang, Y., & Wu, Z. (2009) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31463 · Cited by 866
Development of a chitosan-based wound dressing with improved hemostatic and antimicrobial properties
Ong, S.-Y., Wu, J., Moochhala, S. M., Tan, M.-H., & Lu, J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.07.034 · Cited by 830
The future of biologic coatings for orthopaedic implants
Goodman, S. B., Yao, Z., Keeney, M., & Yang, F. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.074 · Cited by 779
Antibacterial surfaces for biomedical devices
Vasilev, K., Cook, J., & Griesser, H. J. (2009) · Expert Review of Medical Devices · doi:10.1586/erd.09.36 · Cited by 504
Chemical modification of titanium surfaces for covalent attachment of biological molecules
Nanci, A., Wuest, J. D., Peru, L., Brunet, P., Sharma, V., Zalzal, S., & McKee, M. D. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199805)40:2<324::aid-jbm18>3.0.co;2-l · Cited by 503
Research works printed but not linked: 2
- Xiao, 1997, J. Mater. Sci.: Mater. Med., 8, 867
- Nanci, 1998, J. Biomed. Mater. Res., 40, 324, 10.1002/(sici)1097-4636(199805)40:2<324::aid-jbm18>3.0.co;2-l · DOI · Paper page
Cited by
Jiao, Y., Niu, L.-N., Ma, S., Li, J., Tay, F. R., & Chen, J.-H. (2017) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2017.03.001 · Cited by 639
“The quaternized chitosan derivative may also be immobilized on titanium implant surfaces via silanization with aminopropyltriethoxysilane [215] .”
BackgroundVersatile Antibacterial Materials: An Emerging Arsenal for Combatting Bacterial Pathogens
Ding, X., Duan, S., Ding, X., Liu, R., & Xu, F. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201802140 · Cited by 489
Bohara, S., & Suthakorn, J. (2022) · Biomaterials Research · doi:10.1186/s40824-022-00269-3 · Cited by 189
“A Ti implant coated with chitosan in vitro demonstrated prevention of staphylococcus epidermidis ATCC 35,984 and biofilm formation [95].”
Surface treatment strategies to combat implant-related infection from the beginning
Wang, M., & Tang, T. (2019) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2018.09.001 · Cited by 188
“HACC covalently immobilised on titanium surface showed significant inhibition of bacterial adhesion in vitro, while in vivo experiments involving Xray, bacteriology and histopathology analyses confirmed this effect [96].”
ResultSelf-citationKumari, S., Tiyyagura, H. R., Pottathara, Y. B., Sadasivuni, K. K., Ponnamma, D., Douglas, T., Skirtach, A. G., & Mohan, M. (2020) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2020.117487 · Cited by 119
“(Peng et al., 2015) also practised covalent bonding interaction between the coat-substrate interface by covalently bonding the Ti implant surface with quaternized CS.”
BackgroundZhou, C., Yang, Z., Xun, X., Ma, L., Chen, Z., Hu, X., Wu, X., Wan, Y., & Ao, H. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.10.043 · Cited by 91
“Similar results have been reported in our previous studies [27,30,59].”
ResultSelf-citationProgress in Surface Modification of Titanium Implants by Hydrogel Coatings
Chen, H., Feng, R., Xia, T. D., Wen, Z., Li, Q., Qiu, X., Huang, B., & Li, Y. (2023) · Gels · doi:10.3390/gels9050423 · Cited by 70
“Provide a self-protective surfa that prevents bacterial colonisation and implant-associated infections [22]”
BackgroundAo, H., Yang, S., Nie, B., Fan, Q., Zhang, Q., Zong, J., Guo, S., Zheng, X., & Tang, T. (2019) · Journal of Materials Chemistry B · doi:10.1039/c8tb02425a · Cited by 69
Self-citationPiras, A. M., Esin, S., Benedetti, A., Maisetta, G., Fabiano, A., Zambito, Y., & Batoni, G. (2019) · International Journal of Molecular Sciences · doi:10.3390/ijms20246297 · Cited by 68
“Concerning the antiadhesion effect of the grafted polymer, it was evaluated by quantifying the number of viable bacterial cells adhered on the surface and the results obtained are in line with what reported by Peng et al. 2015, for HACC quaternized Ch [51].”
ResultAo, H., Jiang, W., Nie, Y., Zhou, C., Zong, J., Liu, M., Liu, X., & Wan, Y. (2020) · Polymer Testing · doi:10.1016/j.polymertesting.2020.106490 · Cited by 68
Self-citationZhou, C., Ao, H., Han, X., Jiang, W., Yang, Z., Ma, L., Deng, X., & Wan, Y. (2021) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2021.117683 · Cited by 65
Self-citationYang, S., Han, X., Jia, Y., Zhang, H., & Tang, T. (2017) · Polymers · doi:10.3390/polym9120697 · Cited by 52
Self-citationAntimicrobial Properties of Chitosan and Its Derivatives
Másson, M. (2021) · Advances in polymer science · doi:10.1007/12_2021_104 · Cited by 49
Tian, M., Cai, S., Ling, L., Zuo, Y., Wang, Z., Liu, P., Bao, X., & Xu, G. (2022) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2022.106745 · Cited by 47
Chitosan-based materials for dental implantology: A comprehensive review
Mahmood, A., Maher, N., Amin, F., Alqutaibi, A. Y., Kumar, N., & Zafar, M. S. (2024) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2024.131823 · Cited by 39
Natural polymers-based surface engineering of bone scaffolds – A review
Sathiya, K., Ganesamoorthi, S., Mohan, S., Shanmugavadivu, A., & Selvamurugan, N. (2024) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2024.136840 · Cited by 25
Pin-Track Infections: Past, Present, and Future
Iobst, C. (2017) · Journal of Limb Lengthening & Reconstruction · doi:10.4103/jllr.jllr_17_17 · Cited by 21
Coating of chitosan onto bone implants
Mallik, A. K., Chisty, A. H., Kabir, S. F., Khan, M. N., Haque, P., & Rahman, M. M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-821058-1.00001-0 · Cited by 12
Ma, L., Zong, J., Xun, X., Hu, X., Chen, Z., Zhang, Q., Peng, M., Song, B., & Ao, H. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2022.1019332 · Cited by 11
“Radiographic manifestations were assessed with a scoring system previously detailed in the literature (Peng et al., 2015).”
MethodSelf-citationKašparová, P., Zmuda, M., Vaňková, E., Maťátková, O., & Masák, J. (2021) · Folia Microbiologica · doi:10.1007/s12223-021-00898-6 · Cited by 11
Antimicrobial Properties of Chitosan and Chitosan Derivatives
Sahariah, P., Hjálmarsdóttir, M. Á., & Másson, M. (2016) · CRC Press eBooks · doi:10.1201/9781315371399-39 · Cited by 10
Ao, H., Han, X., Zhou, C., Zhou, S., Wang, M., Xun, X., Wu, X., Li, Y., Zong, J., & Wan, Y. (2024) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2024.138673 · Cited by 10
Self-citationSemeshchenko, D., Slullitel, P. A., Farinati, A., Albani-Forneris, A., Piuzzi, N. S., & Buttaro, M. A. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14082610 · Cited by 9
“At the same time, there are studies showing that a titanium implant coating with QACs prevents bacteria attachment in vitro , decreases the infection rates associated with orthopedic implantation in vivo , and promotes implant osseointegration [77].”
Antibacterial Optimization of Highly Deformed Titanium Alloys for Spinal Implants
Kasperkiewicz, K., Major, R., Sypień, A., Marcin, K. O. T., Dyner, M., Major, Ł., Byrski, A., Kopernik, M., & Lackner, J. M. (2021) · Molecules · doi:10.3390/molecules26113145 · Cited by 8
“Nevertheless, all these films have low mechanical stability and adhesion due to grafting to Ti by linking molecules [40,42] or embedding the bioactive molecules in layer-by-layer self-assembled coatings.”
BackgroundHu, X., Zhong, J., Chen, Y., Liu, B., Du, T., Zhu, W., Zheng, M., Liang, H., Ni, J., & Peng, Z. (2025) · Advanced Science · doi:10.1002/advs.202511045 · Cited by 7
Self-citationKhalifa, A. A., & Farouk, O. A. (2025) · Springer eBooks · doi:10.1007/978-981-96-3017-2_6 · Cited by 2
Layer-by-layer coating of drug-loaded microspheres on silicone surfaces for biomedical applications
Lee, S., Park, J., Yook, S., & Jeong, J. (2025) · Macromolecular Research · doi:10.1007/s13233-025-00428-0 · Cited by 2
Harnessing Chitosan and Its Derivatives for Innovative Antimicrobial Biomaterials
Mukherjee, S., Maity, S., Patra, D., & Haldar, J. (2024) · Advances in polymer science · doi:10.1007/12_2024_178 · Cited by 2
Advanced Coating Nanomaterials for Drug Release Applications
Scilletta, N. A., Municoy, S., Bellino, M. G., Soler‐Illia, G. J. A. A., Desimone, M. F., & Catalano, P. N. (2019) · Wiley eBooks · doi:10.1002/9781119580546.ch10 · Cited by 2
Applications of bioactive surface coatings/modifications
Kashyap, V., Chaudhari, H. P., Sachdeva, J. K., & Kumar, R. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-31606-7.00028-4
Metadata
- Authors
- Peng, Z., Ao, H., Wang, L., Guo, S., & Tang, T.
- Affiliations
- Shanghai Jiao Tong University (CN)
- School of Pharmacy
- Corresponding author
- Tang, Tingting
- Venue
- RSC Advances
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2015
- Volume
- 5
- Issue
- 67
- Pages
- 54304-54311
- ISSN
- 2046-2069 (ISSN-L)
- OpenAlex
- W1773257364
- Cited by
- 31
- References
- 50
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 4 · 2023: 1 · 2022: 4 · 2021: 5 · 2020: 2 · 2019: 3 · 2018: 2 · 2017: 3 · 2016: 1
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- RSC Advances (publishedVersion)
- Funders
- National Natural Science Foundation of China
- Science and Technology Commission of Shanghai Municipality
- Natural Science Foundation of Ningbo
- Topics
- Health Sciences › Medicine › Surgery › Orthopedic Infections and Treatments
- Life Sciences › Immunology and Microbiology › Applied Microbiology and Biotechnology › Antimicrobial agents and applications
- Physical Sciences › Engineering › Mechanical Engineering › Surface Treatment and Coatings
- Keywords
- titanium implants, implant coatings, bacterial colonization, implant-associated infection, osteolysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.