The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Antibacterial surfaces for biomedical devices
Abstract
Despite considerable research and development efforts, the problem of infections related to biomedical devices and implants persists. Bacteria evidently can readily colonize surfaces of synthetic materials, such as those used for the fabrication of catheters, hip and knee implants, and many other devices. As the growing colony encapsulates itself with a protective exocellular bacterial polysaccharide layer, the biofilm becomes much harder to combat than circulating bacteria. Thus, there is a strong need to mitigate bacterial colonization by equipping the surfaces of biomedical devices and implants with features such as surface chemistry and surface roughness that are unfavorable for bacterial attachment. Here we review a number of strategies used for the design of antibacterial coatings. We also discuss specific issues that arise from using various types of coatings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bacterial Biofilms: A Common Cause of Persistent Infections
Costerton, J. W., Stewart, P. S., & Greenberg, E. P. (1999) · Science · doi:10.1126/science.284.5418.1318 · Cited by 12,167
Drug/device combinations for local drug therapies and infection prophylaxis
Wu, P., & Grainger, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.031 · Cited by 491
Beyth, N., Yudovin-Farber, I., Bahir, R., Domb, A. J., & Weiss, E. I. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.03.003 · Cited by 470
Two-level antibacterial coating with both release-killing and contact-killing capabilities
Li, Z., Lee, D., Sheng, X., Cohen, R. E., & Rubner, M. F. (2006) · Langmuir · doi:10.1021/la0622166 · Cited by 436
A Switchable Biocompatible Polymer Surface with Self‐Sterilizing and Nonfouling Capabilities
Cheng, G., Xue, H., Zhang, Z., Chen, S., & Jiang, S. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803570 · Cited by 371
Frost, M. C., Reynolds, M. M., & Meyerhoff, M. E. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.006 · Cited by 343
Huang, J., Koepsel, R. R., Murata, H., Wu, W., Lee, S. B., Kowalewski, T., Russell, A. J., & Matyjaszewski, K. (2008) · Langmuir · doi:10.1021/la8003933 · Cited by 231
Cited by
Banerjee, I., Pangule, R. C., & Kane, R. S. (2011) · Advanced Materials · doi:10.1002/adma.201001215 · Cited by 2,749
Silver as Antibacterial Agent: Ion, Nanoparticle, and Metal
Chernousova, S., & Epple, M. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201205923 · Cited by 2,264
Polymeric materials with antimicrobial activity
Muñoz-Bonilla, A., & Fernández-García, M. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.08.005 · Cited by 1,221
Antimicrobial Activity of Metal and Metal‐Oxide Based Nanoparticles
Gold, K., Slay, B., Knackstedt, M., & Gaharwar, A. K. (2018) · Advanced Therapeutics · doi:10.1002/adtp.201700033 · Cited by 758
Kaczmarek, B. (2020) · Materials · doi:10.3390/ma13143224 · Cited by 624
Metadata
- Authors
- Vasilev, K., Cook, J., & Griesser, H. J.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2009-09
- Volume
- 6
- Issue
- 5
- Pages
- 553-567
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2101362243
- Cited by
- 504
- References
- 7
- FWCI
- 9.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Antibacterial surfaces for biomedical devices. https://app.cochat.ai/papers/10.1586/erd.09.36
- The paper
- Vasilev, K., Cook, J., & Griesser, H. J. (2009). Antibacterial surfaces for biomedical devices. Expert Review of Medical Devices. https://doi.org/10.1586/erd.09.36
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.