Ternary NiCoP nanosheet array on a Ti mesh: a high-performance electrochemical sensor for glucose detection
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
NiCoP nanosheet array acts as a high-active catalyst electrode for glucose electro-oxidation in alkaline media. As a non-enzyme electrochemical glucose sensor, it shows a low detection limit of 0.13 μM (S/N = 3) and a high sensitivity of 14 586 μA mM−1 cm−2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shi, Y., & Zhang, B. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00434a · Cited by 3,253
Nanostructured Nickel Phosphide as an Electrocatalyst for the Hydrogen Evolution Reaction
Popczun, E. J., McKone, J. R., Read, C. G., Biacchi, A. J., Wiltrout, A. M., Lewis, N. S., & Schaak, R. E. (2013) · Journal of the American Chemical Society · doi:10.1021/ja403440e · Cited by 2,911
Tian, J., Liu, Q., Asiri, A. M., & Sun, X. (2014) · Journal of the American Chemical Society · doi:10.1021/ja503372r · Cited by 2,373
Self-citationTwo-dimensional transition metal dichalcogenide nanosheet-based composites
Tan, C., & Zhang, H. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00182f · Cited by 1,605
Cited by
Recent advances in electrochemical non-enzymatic glucose sensors – A review
Hwang, D.-W., Lee, S., Seo, M., & Chung, T. D. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.05.051 · Cited by 788
Electrochemical non-enzymatic glucose sensors: recent progress and perspectives
Wei, M., Qiao, Y., Zhao, H., Liang, J., Li, T., Luo, Y., Lu, S., Shi, X., Lu, W., & Sun, X. (2020) · Chemical Communications · doi:10.1039/d0cc05650b · Cited by 467
Self-citationXie, L., Zhang, R., Cui, L., Liu, D., Hao, S., Ma, Y., Du, G., Asiri, A. M., & Sun, X. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201610776 · Cited by 388
Self-citationLiu, D., Liu, T., Zhang, L., Qu, F., Du, G., Asiri, A. M., & Sun, X. (2017) · Journal of Materials Chemistry A · doi:10.1039/c6ta11127k · Cited by 359
Self-citationLi, Y., Xie, M., Zhang, X., Liu, Q., Lin, D., Xu, C., Xie, F., & Sun, X. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.09.076 · Cited by 354
Self-citationCobalt nitride nanowire array as an efficient electrochemical sensor for glucose and H2O2 detection
Xie, F., Cao, X., Qu, F., Asiri, A. M., & Sun, X. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.08.098 · Cited by 322
Self-citationAl-Doped CoP nanoarray: a durable water-splitting electrocatalyst with superhigh activity
Zhang, R., Tang, C., Kong, R., Du, G., Asiri, A. M., Chen, L., & Sun, X. (2017) · Nanoscale · doi:10.1039/c7nr00740j · Cited by 308
Self-citationDesign and Application of Foams for Electrocatalysis
Zhu, W., Zhang, R., Qu, F., Asiri, A. M., & Sun, X. (2017) · ChemCatChem · doi:10.1002/cctc.201601607 · Cited by 281
Self-citationBi, L., Gao, X., Zhang, L., Wang, D., Zou, X., & Xie, T. (2018) · ChemSusChem · doi:10.1002/cssc.201701574 · Cited by 270
Hou, C.-C., Li, Q., Wang, C.-J., Peng, C.-Y., Chen, Q.-Q., Ye, H.-F., Fu, W.-F., Che, C.-M., López, N., & Chen, Y. (2017) · Energy & Environmental Science · doi:10.1039/c7ee01553d · Cited by 267
High-performance non-enzymatic glucose detection: using a conductive Ni-MOF as an electrocatalyst
Qiao, Y., Liu, Q., Lu, S., Chen, G., Gao, S., Lu, W., & Sun, X. (2020) · Journal of Materials Chemistry B · doi:10.1039/d0tb00131g · Cited by 247
Self-citationWu, X., Bao, C., Niu, Q., & Lu, W. (2019) · Nanotechnology · doi:10.1088/1361-6528/aafe53 · Cited by 28
Metadata
- Authors
- Wang, Z., Cao, X., Liu, D., Hao, S., Du, G., Asiri, A. M., & Sun, X.
- Venue
- Chemical Communications
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2016
- Volume
- 52
- Issue
- 100
- Pages
- 14438-14441
- ISSN
- 1359-7345 (ISSN-L)
- 1364-548X
- OpenAlex
- W2551844103
- Cited by
- 104
- References
- 4
- FWCI
- 10.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.