The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Recent progress in the development of fluorescent, luminescent and colorimetric probes for detection of reactive oxygen and nitrogen species
Abstract
Reactive oxygen (ROS) and nitrogen (RNS) species cause oxidative and nitrosative stresses, respectively. These stresses are implicated not only in diverse physiological processes but also in various pathological processes, including cancer and neurodegenerative disorders. In addition, some ROS and RNS in the environment are pollutants that threaten human health. As a consequence of these effects, sensitive methods, which can be employed to selectively monitor ROS and RNS in live cells, tissues and organisms as well as in environmental samples, are needed so that their biological roles can be understood and their concentrations in environmental samples can be determined. In this review, fluorescent, luminescent and colorimetric ROS and RNS probes, which have been developed since 2011, are comprehensively discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Peroxynitrite: biochemistry, pathophysiology and development of therapeutics
Szabó, C., Ischiropoulos, H., & Radi, R. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2222 · Cited by 2,134
Chemistry and biology of reactive oxygen species in signaling or stress responses
Dickinson, B. C., & Chang, C. J. (2011) · Nature Chemical Biology · doi:10.1038/nchembio.607 · Cited by 1,821
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Self-citationMiranda, K. M., Paolocci, N., Katori, T., Thomas, D. D., Ford, E., Bartberger, M. D., Espey, M. G., Kass, D. A., Feelisch, M., Fukuto, J. M., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1430507100 · Cited by 283
Rapid Detection of Hydrogen Peroxide Based on Aggregation Induced Ratiometric Fluorescence Change
Li, G., Zhu, D., Liu, Q., Xue, L., & Jiang, H. (2013) · Organic Letters · doi:10.1021/ol4000845 · Cited by 98
A selenium-contained aggregation-induced “turn-on” fluorescent probe for hydrogen peroxide
Liao, Y.-X., Li, K., Wu, M.-Y., Wu, T., & Yu, X.-Q. (2014) · Organic & Biomolecular Chemistry · doi:10.1039/c4ob00206g · Cited by 58
Cited by
Fluorescent chemical probes for accurate tumor diagnosis and targeting therapy
Gao, M., Yu, F., Lv, C., Choo, J., & Chen, L. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00908e · Cited by 827
Yang, B., Chen, Y., & Shi, J. (2019) · Advanced Materials · doi:10.1002/adma.201901778 · Cited by 601
Theranostic Fluorescent Probes
Sharma, A., Verwilst, P., Li, M., Ma, D., Singh, N., Yoo, J., Kim, Y., Yang, Y., Zhu, J.-H., Huang, H., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00778 · Cited by 499
Reaction-based BODIPY probes for selective bio-imaging
Kolemen, S., & Akkaya, E. U. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2017.06.021 · Cited by 357
Near-infrared (NIR) fluorescence-emitting small organic molecules for cancer imaging and therapy
Li, H., Kim, Y., Jung, H., Hyun, J. Y., & Shin, I. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00722c · Cited by 356
Self-citation
Metadata
- Authors
- Chen, X., Wang, F., Hyun, J. Y., Wei, T., Qiang, J., Ren, X., Shin, I., & Yoon, J.
- Venue
- Chem. Soc. Rev.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2016
- Volume
- 45
- Issue
- 10
- Pages
- 2976-3016
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- OpenAlex
- W2338274451
- Cited by
- 1,166
- References
- 6
- FWCI
- 8.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.