Cited by 111Electrochemical sensors and biosensorsAdvanced Sensor and Energy Harvesting MaterialsAdvanced biosensing and bioanalysis techniques

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Embroidered electrochemical sensors for biomolecular detection

Liu, Xiyuan, Lillehoj, Peter B.·2016·Lab on a Chip

Abstract

We demonstrate a unique textile-based electrochemical sensor utilizing embroidered electrodes for rapid biomolecular detection.

Overview

Integrity signals

Registry

Crossref · 10.1039/c6lc00307a

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 22 references

Research works printed but not linked: 2

  1. Liu, 2015, J. Lab. Autom., 2211068215573662
  2. G. Loriga , N.Taccini, D.De Rossi and R.Paradiso, in 27th Annual International Conference of the Engineering in Medicine and Biology Society, 2005, IEEE-EMBS 2005, 2005, pp. 7349–7352

Cited by

Sorted by citations

Items 101–111 of 111

Metadata

Authors
Liu, X., & Lillehoj, P. B.
Affiliations
Michigan State University (US)
Corresponding author
Lillehoj, Peter B.
Venue
Lab on a Chip
Published
2016
Volume
16
Issue
11
Pages
2093-2098
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2344779750
Cited by
110
References
22
Citations by year
2026: 9 · 2025: 15 · 2024: 15 · 2023: 10 · 2022: 20 · 2021: 16 · 2020: 6 · 2019: 8 · 2018: 9 · 2017: 2
FWCI
2.92
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
Funders
Division of Electrical, Communications and Cyber Systems (ECCS-135056)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
Keywords
conductive threads, enzyme immobilization, flexible electrodes, smart textiles, glucose detection, lactate detection, whole blood analysis, multiplexed biosensing, mechanical robustness, wearable biosensors
MeSH terms
Blood Glucose, Electrochemistry, Equipment Design, Humans, Stress, Mechanical, Time Factors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review