Cited by 330Advanced Sensor and Energy Harvesting MaterialsNon-Invasive Vital Sign MonitoringWireless Body Area Networks

BIOTEX—Biosensing Textiles for Personalised Healthcare Management

Open access
Coyle, Shirley, Lau, King-Tong, Moyna, Niall, O'Gorman, Donal, Diamond, Dermot, Di Francesco, Fabio, Costanzo, Daniele, Salvo, Pietro +16 more·2010·IEEE Transactions on Information Technology in Biomedicine

Abstract

Textile-based sensors offer an unobtrusive method of continually monitoring physiological parameters during daily activities. Chemical analysis of body fluids, noninvasively, is a novel and exciting area of personalized wearable healthcare systems. BIOTEX was an EU-funded project that aimed to develop textile sensors to measure physiological parameters and the chemical composition of body fluids, with a particular interest in sweat. A wearable sensing system has been developed that integrates a textile-based fluid handling system for sample collection and transport with a number of sensors including sodium, conductivity, and pH sensors. Sensors for sweat rate, ECG, respiration, and blood oxygenation were also developed. For the first time, it has been possible to monitor a number of physiological parameters together with sweat composition in real time. This has been carried out via a network of wearable sensors distributed around the body of a subject user. This has huge implications for the field of sports and human performance and opens a whole new field of research in the clinical setting.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/titb.2009.2038484

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Previously reported sweat-based and other non-invasive biosensors either monitor only one analyte at a time or lack on-site signal processing and calibration for accurate physiological analysis.

    “Previously reported sweat-based and other non-invasive biosensors either can only monitor a single analyte at a time or lack on-site signal processing circuitry and sensor calibration mechanisms for accurate analysis of the physiological state14–18.”

    From Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis (2016) · cites this paper as [16]

    The Introduction describes limitations of earlier sweat-collection methods, but does not say that previously reported biosensors were restricted to one analyte or lacked on-site processing and calibration. It instead describes BIOTEX’s multiparametric patch; the sensor and control-electronics sections discuss calibration before trials and signal processing, without establishing the claimed either-or limitation of prior devices. (LLM, conf=0.76)

    Experimental — accuracy not yet measured
  • Within the BIOTEX project, researchers have developed a textile based fluid collecting system and sensors for in-vitro and in-vivo testing of pH, sodium and conductivity from body sweat.

    “Within this project, researchers have developed a textile based fluid collecting system and sensors for in-vitro and in-vivo testing of pH, sodium and conductivity from body sweat [31,32].”
  • By in-vitro and in-vivo testing of the wearable system, researchers have shown that the system can be used for real-time analysis of sweat during physical activity.

    “By in-vitro and in-vivo testing of the wearable system, researchers have shown that the system can be used for real-time analysis of sweat during physical activity.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. J. Massie, K. Gaskin, P. Van Asperen, and B. Wilcken, "Sweat testing following newborn screening for cystic fibrosis," Pediatr. Pulmonol., vol. 29, pp. 452-456, 2000.

Cited by

Sorted by citations

Authors
Coyle, S., Lau, K.-T., Moyna, N., O'Gorman, D., Diamond, D., Di Francesco, F., Costanzo, D., Salvo, P., Trivella, M. G., De Rossi, D. E., Taccini, N., Paradiso, R., Porchet, J.-A., Ridolfi, A., Luprano, J., Chuzel, C., Lanier, T., Revol-Cavalier, F., Schoumacker, S., Mourier, V., Chartier, I., Convert, R., De-Moncuit, H., & Bini, C.
Affiliations
  • Clarity Centre for Sensor Web Technologies (IE)
  • Istituto di Fisiologia Clinica (IT)
  • University of Pisa (IT)
  • Smartex (Italy) (IT)
  • Swiss Center for Electronics and Microtechnology (Switzerland) (CH)
Venue
IEEE Transactions on Information Technology in Biomedicine
Published
2010-03
Volume
14
Issue
2
Pages
364-370
ISSN
  • 1089-7771 (ISSN-L)
  • 1558-0032
OpenAlex
W2166680787
Cited by
330
References
27
Citations by year
2026: 8 · 2025: 10 · 2024: 11 · 2023: 18 · 2022: 12 · 2021: 18 · 2020: 28 · 2019: 39 · 2018: 27 · 2017: 20 · 2016: 25 · 2015: 26 · 2014: 28 · 2013: 21 · 2012: 19
FWCI
11.30
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Information Technology in Biomedicine (publishedVersion)
  • PubMed (publishedVersion)
  • Arrow@dit (Dublin Institute of Technology) (submittedVersion)
  • CINECA IRIS Institutial research information system (University of Pisa) (submittedVersion)
  • Dublin City University Open Access Institutional Repository (Dublin City University) (submittedVersion)
Funders
  • European Commission
  • Science Foundation Ireland (07/CE/I1147)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
textile sensors, wearable sensors, sweat analysis, physiological monitoring, conductivity sensor, pH sensor, sweat rate, electrocardiogram, respiratory monitoring, blood oxygenation, personalized healthcare, sports performance monitoring
MeSH terms
Abdomen, Artificial Intelligence, Clothing, Electrocardiography, Electronics, Medical, Humans, Hydrogen-Ion Concentration, Monitoring, Physiologic, Oximetry, Respiration, Sternum, Sweat, Telemetry, Textiles, Thorax, Precision Medicine

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review