We report the design and fabrication of a robust fluidic platform built out of inert plastic materials and micromachined features that promote optimized convective fluid transport. The platform is tested for perfusion interrogation of rodent and human pancreatic islets, dynamic secretion of hormones, concomitant live-cell imaging, and optogenetic stimulation of genetically engineered islets. A coupled quantitative fluid dynamics computational model of glucose stimulated insulin secretion and fluid dynamics was first utilized to design device geometries that are optimal for complete perfusion of three-dimensional islets, effective collection of secreted insulin, and minimization of system volumes and associated delays. Fluidic devices were then fabricated through rapid prototyping techniques, such as micromilling and laser engraving, as two interlocking parts from materials that are non-absorbent and inert. Finally, the assembly was tested for performance using both rodent and human islets with multiple assays conducted in parallel, such as dynamic perfusion, staining and optogenetics on standard microscopes, as well as for integration with commercial perfusion machines. The optimized design of convective fluid flows, use of bio-inert and non-absorbent materials, reversible assembly, manual access for loading and unloading of islets, and straightforward integration with commercial imaging and fluid handling systems proved to be critical for perfusion assay, and particularly suited for time-resolved optogenetics studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The unique cytoarchitecture of human pancreatic islets has implications for islet cell function
Cabrera, O., Berman, D. M., Kenyon, N. S., Ricordi, C., Berggren, P.-O., & Caicedo, A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0510790103 · Cited by 1,312
Self-citationOrgans-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Hering, B. J., Clarke, W. R., Bridges, N. D., Eggerman, T. L., Alejandro, R., Bellin, M. D., Chaloner, K., Czarniecki, C. W., Goldstein, J. S., Hunsicker, L. G., et al. (2016) · Diabetes Care · doi:10.2337/dc15-1988 · Cited by 645
Stem cells versus plasticity in liver and pancreas regeneration
Kopp, J. L., Grompe, M., & Sander, M. (2016) · Nature Cell Biology · doi:10.1038/ncb3309 · Cited by 176
Cited by
Campbell, S. B., Wu, Q., Yazbeck, J., Liu, C., Okhovatian, S., & Radisic, M. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00640 · Cited by 297
Organoid microphysiological system preserves pancreatic islet function within 3D matrix
Patel, S. N., Ishahak, M., Chaimov, D., Velraj, A., LaShoto, D., Hagan, D. W., Buchwald, P., Phelps, E. A., Agarwal, A., & Stabler, C. L. (2021) · Science Advances · doi:10.1126/sciadv.aba5515 · Cited by 97
Self-citationRoadblocks confronting widespread dissemination and deployment of Organs on Chips
Alver, C. G., Drabbe, E., Ishahak, M., & Agarwal, A. (2024) · Nature Communications · doi:10.1038/s41467-024-48864-3 · Cited by 74
“3B), a subtractive manufacturing technique where selective removal of a base substrate generates microscale features in the substrate 3,4,61,77 .”
MethodSelf-citation
Metadata
- Authors
- Lenguito, G., Chaimov, D., Weitz, J. R., Rodriguez-Diaz, R., Rawal, S. A. K., Tamayo-Garcia, A., Caicedo, A., Stabler, C. L., Buchwald, P., & Agarwal, A.
- Venue
- Lab on a Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 17
- Issue
- 5
- Pages
- 772-781
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2581348935
- Cited by
- 58
- References
- 4
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Resealable, optically accessible, PDMS-free fluidic platform for ex vivo interrogation of pancreatic islets. https://app.cochat.ai/papers/10.1039/c6lc01504b
- The paper
- Lenguito, G., Chaimov, D., Weitz, J. R., Rodriguez-Diaz, R., Rawal, S. A. K., Tamayo-Garcia, A., Caicedo, A., Stabler, C. L., Buchwald, P., & Agarwal, A. (2017). Resealable, optically accessible, PDMS-free fluidic platform for ex vivo interrogation of pancreatic islets. Lab on a Chip. https://doi.org/10.1039/c6lc01504b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.