The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Human skin interactive self-powered wearable piezoelectric bio-e-skin by electrospun poly-l-lactic acid nanofibers for non-invasive physiological signal monitoring
Abstract
An electrospun PLLA fiber based flexible, piezoelectric bio-e-skin that can detect human physiological signals is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Ultra-stretchable and skin-mountable strain sensors using carbon nanotubes–Ecoflex nanocomposites
Amjadi, M., Yoon, Y. J., & Park, I. (2015) · Nanotechnology · doi:10.1088/0957-4484/26/37/375501 · Cited by 817
Sensitive, High-Strain, High-Rate Bodily Motion Sensors Based on Graphene–Rubber Composites
Boland, C. S., Khan, U., Backes, C., O’Neill, A., McCauley, J., Duane, S., Shanker, R., Liu, Y., Jurewicz, I., Dalton, A. B., et al. (2014) · ACS Nano · doi:10.1021/nn503454h · Cited by 793
A Highly Elastic, Capacitive Strain Gauge Based on Percolating Nanotube Networks
Cohen, D. J., Mitra, D., Peterson, K., & Maharbiz, M. M. (2012) · Nano Letters · doi:10.1021/nl204052z · Cited by 501
Cheng, Y., Wang, R., Zhai, H., & Sun, J. (2017) · Nanoscale · doi:10.1039/c7nr00121e · Cited by 165
Cited by
Piezoelectric Biomaterials for Sensors and Actuators
Chorsi, M. T., Curry, E. J., Chorsi, H. T., Das, R., Baroody, J., Purohit, P. K., Ilies, H., & Nguyen, T. D. (2019) · Advanced Materials · doi:10.1002/adma.201802084 · Cited by 865
Electroactive poly(vinylidene fluoride)-based structures for advanced applications
Ribeiro, C., Costa, C. M., Correia, D. M., Nunes-Pereira, J., Oliveira, J., Martins, P., Gonçalves, R., Cardoso, V. F., & Lanceros-Méndez, S. (2018) · Nature Protocols · doi:10.1038/nprot.2017.157 · Cited by 688
Piezoelectric materials for flexible and wearable electronics: A review
Wu, Y., Ma, Y., Zheng, H., & Ramakrishna, S. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.110164 · Cited by 521
Piezoelectric nanogenerators for personalized healthcare
Deng, W., Zhou, Y., Libanori, A., Chen, G., Yang, W., & Chen, J. (2022) · Chemical Society Reviews · doi:10.1039/d1cs00858g · Cited by 434
Capuana, E., Lopresti, F., Ceraulo, M., & La Carrubba, V. (2022) · Polymers · doi:10.3390/polym14061153 · Cited by 301
Metadata
- Authors
- Sultana, A., Ghosh, S. K., Sencadas, V., Zheng, T., Higgins, M. J., Middya, T. R., & Mandal, D.
- Venue
- Journal of Materials Chemistry B
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2017
- Volume
- 5
- Issue
- 35
- Pages
- 7352-7359
- ISSN
- 2050-750X (ISSN-L)
- 2050-7518
- OpenAlex
- W2742645712
- Cited by
- 178
- References
- 7
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.