Detection of Escherichia coli bacteria by impact electrochemistry
Abstract
We report the redox mediated detection of Escherichia coli bacteria at carbon microelectrodes, using the impact electrochemistry technique. By employing N,N,N',N'-tetramethyl-para-phenylene-diamine (TMPD) as redox mediator a concentration dependency for bacteria impacts was observed, whereby its impact frequency is shown to be in good agreement with theoretically predicted values.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Since 2015, most reports in single-impact electrochemistry of bacteria concern E. coli as a model bacterium.
“Since 2015, most of the reports in this area concern Escherichia coli (E.coli) as a model bacterium but this sensitive electro-analytical technique has not proved to be efficient for selective detection yet, except for the discrimination between Grampositive and Gram-negative bacteria [30,32].”
From Trends in single-impact electrochemistry for bacteria analysis (2023) · cites this paper as [32]
Several studies deal with the use of redox mediators for probing the electrochemical activity of a bacterium.
“In order to develop single-impact electrochemistry toward the identification of bacterial cells, several studies deal with the use of redox mediators for probing the electrochemical activity of the bacterium [32][33][34].”
From Trends in single-impact electrochemistry for bacteria analysis (2023) · cites this paper as [32]
Single-impact electrochemistry has not proved efficient for selective detection of bacteria yet, except for discrimination between Gram-positive and Gram-negative bacteria.
“Since 2015, most of the reports in this area concern Escherichia coli (E.coli) as a model bacterium but this sensitive electro-analytical technique has not proved to be efficient for selective detection yet, except for the discrimination between Grampositive and Gram-negative bacteria [30,32].”
From Trends in single-impact electrochemistry for bacteria analysis (2023) · cites this paper as [32]
Lee et al. demonstrated a linear relationship between collision frequency f_exp and E. coli concentration C_bac, as expected by Equation 1.
“The authors have demonstrated a linear relationship between the collision frequency f exp (number of step-shaped transients) and the E. coli concentration C bac , as expected by Equation 1 below (in conditions where the mass transport is controlled by diffusion) [10,16,32].”
From Trends in single-impact electrochemistry for bacteria analysis (2023) · cites this paper as [32]
The TMPD technique is an efficient method to discriminate living bacteria from dead ones (no cytochrome c oxidase activity).
“This technique is an efficient method to discriminate living bacteria from dead ones (no cytochrome c oxidase activity) and it also shows the expected linear relationship between the collision frequency and the E. coli concentration in solution (see Equation 1) [32].”
From Trends in single-impact electrochemistry for bacteria analysis (2023) · cites this paper as [32]
When bacteria enter the diffusion layer, a feedback redox cycle is created and a reductive current spike is detected, corresponding to regeneration of TMPD•+ in the periphery of the bacterium.
“When the bacteria enter the diffusion layer, a feedback redox cycle is created and a reductive current spike (current increase) is detected in the chronoamperometry measurement, corresponding to the regeneration of TMPD •+ in the periphery of the bacterium (Fig. 3a) [32].”
From Trends in single-impact electrochemistry for bacteria analysis (2023) · cites this paper as [32]
Couto et al. deals with the use of TMPD as a redox mediator, which enables electrochemical recognition of bacterial cytochrome c oxidases without the need of cell lysis.
“For the detection of E. coli by impact electrochemistry, the work of Couto et al. deals with the use of N,N,N',N'tetramethyl-para-phenylene-diamine (TMPD) as a redox mediator, which enables the electrochemical recognition of bacterial cytochrome c oxidases without the need of cell lysis (Fig. 3a) [32].”
From Trends in single-impact electrochemistry for bacteria analysis (2023) · cites this paper as [32]
Because E. coli cells include cytochrome c oxidases in their membranes, they are able to oxidize extracellular TMPD to TMPD•+.
“Because E. coli cells include cytochrome c oxidases in their membranes, they are able to oxidize extracellular TMPD to TMPD •+ .”
From Trends in single-impact electrochemistry for bacteria analysis (2023) · cites this paper as [32]
The TMPD technique shows the expected linear relationship between collision frequency and E. coli concentration in solution.
“This technique is an efficient method to discriminate living bacteria from dead ones (no cytochrome c oxidase activity) and it also shows the expected linear relationship between the collision frequency and the E. coli concentration in solution (see Equation 1) [32].”
From Trends in single-impact electrochemistry for bacteria analysis (2023) · cites this paper as [32]
Cited by
Sorted by citations
Single-entity electrochemistry of collision in sensing applications
Sekretareva, A. (2021) · Sensors and Actuators Reports · doi:10.1016/j.snr.2021.100037 · Cited by 41 · see citing works
Trends in single-impact electrochemistry for bacteria analysis
Smida, H., Langlard, A., Ameline, D., Thobie-Gautier, C., Boujtita, M., & Lebègue, E. (2023) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-04568-z · Cited by 22 · see citing works
Lebègue, E., Costa, N. L., Louro, R. O., & Barrière, F. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab9e39 · Cited by 17 · see citing works
Chen, X., Peng, M., Peng, Z., & Zhou, Y. (2026) · Chemistry – A European Journal · doi:10.1002/chem.202503631 · Cited by 1 · see citing works
- Authors
- Couto, R. A. S., Chen, L., Kuss, S., & Compton, R. G.
- Affiliations
- Universidade do Porto (PT)
- University of Oxford (GB)
- Corresponding author
- Compton, Richard G.
- Venue
- The Analyst
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2018
- Volume
- 143
- Issue
- 20
- Pages
- 4840-4843
- ISSN
- 0003-2654 (ISSN-L)
- 1364-5528
- OpenAlex
- W2889836695
- Cited by
- 61
- References
- 0
- Citations by year
- 2026: 6 · 2025: 4 · 2024: 7 · 2023: 10 · 2022: 13 · 2021: 9 · 2020: 7 · 2019: 5
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Analyst (publishedVersion)
- PubMed (publishedVersion)
- Funders
- FP7 Ideas: European Research Council (320403)
- Fundação para a Ciência e a Tecnologia (PD/BD/127797/2016)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Environmental Science › Environmental Engineering › Microbial Fuel Cells and Bioremediation
- Keywords
- Escherichia coli detection, carbon microelectrodes, TMPD, redox mediators, bacterial sensing
- MeSH terms
- Carbon, Electron Transport Complex IV, Escherichia coli, Microelectrodes, Oxidation-Reduction, Tetramethylphenylenediamine, Escherichia coli Proteins, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review