Investigation of ash deposition dynamic process in an industrial biomass CFB boiler burning high alkali and chlorine fuel
Open accessAbstract
Analysis of multiple deposits with different deposition times, piecing together the whole deposition process in 50 MW biomass CFB boiler.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Alkali salt aerosols condense onto the heating surface of boilers to form a sticky initial layer.
“The alkali salt aerosols condense onto the heating surface of boilers to form a “sticky initial layer”.”
From High Temperature Corrosion Resistant and Anti-slagging Coatings for Boilers: A Review (2024) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Boiler deposits from firing biomass fuels
Miles, T. R., Miles, T. R., Baxter, L. L., Bryers, R. W., Jenkins, B. M., & Oden, L. L. (1996) · Biomass and Bioenergy · doi:10.1016/0961-9534(95)00067-4 · Cited by 420 · see citing works
Deposition of potassium salts on heat transfer surfaces in straw-fired boilers: a pilot-scale study
Nielsen, H. P., Baxter, L. L., Sclippab, G., Morey, C., Frandsen, F. J., & Dam-Johansen, K. (2000) · Fuel · doi:10.1016/s0016-2361(99)00090-3 · Cited by 202 · see citing works
Influence of deposit formation on corrosion at a straw-fired boiler
Hansen, L. A., Nielsen, H. P., Frandsen, F. J., Dam-Johansen, K., Hørlyck, S., & Karlsson, A. (2000) · Fuel Processing Technology · doi:10.1016/s0378-3820(00)00063-1 · Cited by 195 · see citing works
Condensation Behaviors of Potassium during Biomass Combustion
Jin, X., Ye, J., Deng, L., & Che, D. (2017) · Energy & Fuels · doi:10.1021/acs.energyfuels.6b03381 · Cited by 37 · see citing works
Flagged first, then by citations
Research works printed but not linked: 30
- Vassilev S. V. Baxter D. Andersen L. K. Vassileva C. G. Fuel 2010 89 913 933 10.1016/j.fuel.2009.10.022 · DOI · Paper page
- Jayaraman K. Kok M. V. Gokalp I. J. Therm. Anal. Calorim. 2017 127 1361 1370 10.1007/s10973-016-6042-1 · DOI
- Li L. Yu C. Huang F. Bai J. Fang M. Luo Z. Energy Fuels 2012 26 6008 6014 10.1021/ef301008n · DOI
- Zhou Y. Zhang Z. Zhang Y. Wang Y. Yu Y. Ji F. Ahmad R. Dong R. Renewable Sustainable Energy Rev. 2016 54 1412 1428 10.1016/j.rser.2015.09.096 · DOI
- Vassilev S. V. Baxter D. Andersen L. K. Vassileva C. G. Fuel 2010 89 913 933 10.1016/j.fuel.2009.10.022 · DOI · Paper page
- Valmari T. Lind T. M. Kauppinen E. I. Sfiris G. Nilsson K. Maenhaut W. Energy Fuels 1999 13 379 389 10.1021/ef980085d · DOI
- Bjorkman E. Stromberg B. Energy Fuels 1997 11 1026 1032 10.1021/ef970031o · DOI
- Niu Y. Tan H. Ma L. Pourkashanian M. Liu Z. Liu Y. Wang X. Liu H. Xu T. Energy Fuels 2010 24 6220 10.1021/ef1013924 · DOI
- Jenkins B. M. Baxter L. L. Miles T. R. Miles T. R. Fuel Process. Technol. 1998 54 17 46 10.1016/S0378-3820(97)00059-3 · DOI
- Nielsen H. P. Frandsen F. J. Dam-Johansen K. Baxter L. L. Prog. Energy Combust. Sci. 2000 26 283 298 10.1016/S0360-1285(00)00003-4 · DOI · Paper page
- van Lith S. C. Jensen P. A. Frandsen F. J. Glarborg P. Energy Fuels 2008 22 1598 1609 10.1021/ef060613i · DOI
- Knudsen J. N. Jensen P. A. Dam-Johansen K. Energy Fuels 2004 18 1385 1399 10.1021/ef049944q · DOI
- Davidsson K. O. Korsgren J. G. Pettersson J. Jaglid U. Fuel 2002 81 137 142 10.1016/S0016-2361(01)00132-6 · DOI
- Chen C. Yu C. Zhang H. Zhai X. Luo Z. Fuel 2016 167 180 187 10.1016/j.fuel.2015.11.030 · DOI
- Jensen P. A. Frandsen F. J. Dam-Johansen K. Sander B. Energy Fuels 2000 14 1280 1285 10.1021/ef000104v · DOI
- Vassilev S. V. Baxter D. Andersen L. K. Vassileva C. G. Fuel 2013 105 40 76 10.1016/j.fuel.2012.09.041 · DOI
- Johansen J. M. Jakobsen J. G. Frandsen F. J. Glarborg P. Energy Fuels 2011 25 4961 4971 10.1021/ef201098n · DOI · Paper page
- Jensen P. A. Frandsen F. J. Hansen J. Dam-Johansen K. Henriksen N. Horlyck S. Energy Fuels 2004 18 378 384 10.1021/ef030097l · DOI · Paper page
- Valmari T. Lind T. M. Kauppinen E. I. Sfiris G. Nilsson K. Maenhaut W. Energy Fuels 1999 13 390 395 10.1021/ef9800866 · DOI
- Bashir M. S. Jensen P. A. Frandsen F. Wedel S. Dam-Johansen K. Wadenback J. Pedersen S. T. Energy Fuels 2012 26 2317 2330 10.1021/ef201680k · DOI
- Tobiasen L. Skytte R. Pedersen L. S. Pedersen S. T. Lindberg M. A. Fuel Process. Technol. 2007 88 1108 1117 10.1016/j.fuproc.2007.06.017 · DOI
- Jensen P. A. Stenholm M. Hald P. Energy Fuels 1997 11 1048 1055 10.1021/ef960154t · DOI
- Zbogar A. Jensen P. A. Frandsen F. J. Hansen J. Glarborg P. Energy Fuels 2006 20 512 519 10.1021/ef050037a · DOI
- Bashir M. S. Jensen P. A. Frandsen F. Wedel S. Dam-Johansen K. Wadenback J. Energy Fuels 2012 26 5241 5255 10.1021/ef300611v · DOI
- Madhiyanon T. Sathitruangsak P. Sungworagarn S. Pipatmanomai S. Tia S. Fuel Process. Technol. 2012 96 250 264 10.1016/j.fuproc.2011.12.020 · DOI
- Skrifvars B. J. Lauren T. Hupa M. Korbee R. Ljung P. Fuel 2004 83 1371 1379 10.1016/j.fuel.2004.01.008 · DOI
- Liu Y. Cheng L. Ji J. Wang Q. Fang M. RSC Adv. 2018 8 33817 33827 10.1039/C8RA05997G PMC9086940 35548841 · DOI
- Retschitzegger S. Gruber T. Brunner T. Obernberger I. Fuel Process. Technol. 2015 137 148 156 10.1016/j.fuproc.2015.03.026 · DOI
- Retschitzegger S. Gruber T. Brunner T. Obernberger I. Fuel Process. Technol. 2016 142 59 70 10.1016/j.fuproc.2015.09.021 · DOI
- Niu Y. Zhu Y. Tan H. Hui S. Jing Z. Xu W. Fuel Process. Technol. 2014 128 499 508 10.1016/j.fuproc.2014.07.038 · DOI · Paper page
Cited by
Sorted by citations
High Temperature Corrosion Resistant and Anti-slagging Coatings for Boilers: A Review
Khantisopon, K., Singh, S., Jitputti, J., Berndt, C. C., & Ang, A. S. M. (2024) · High Temperature Corrosion of Materials · doi:10.1007/s11085-024-10251-0 · Cited by 24 · see citing works
- Authors
- Zhang, H., Yu, C., & Luo, Z.
- Affiliations
- State Key Laboratory of Clean Energy Utilization (CN)
- Corresponding author
- Luo, Zhongyang
- Venue
- RSC Advances
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2020
- Volume
- 10
- Issue
- 36
- Pages
- 21420-21426
- ISSN
- 2046-2069 (ISSN-L)
- PMC
- PMC9054359
- OpenAlex
- W3033435377
- Cited by
- 13
- References
- 4
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 3 · 2022: 3 · 2021: 2
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- RSC Advances (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (51661125012)
- National Science Foundation (51661125012)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Thermochemical Biomass Conversion Processes
- Physical Sciences › Engineering › Mechanical Engineering › Coal Combustion and Slurry Processing
- Physical Sciences › Engineering › Aerospace Engineering › High-Temperature Coating Behaviors
- Keywords
- ash deposition, biomass combustion, circulating fluidized bed boiler, superheater, thermophoretic deposition, surface temperature effects
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review