Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index; none of the 7 sources its claims cite is checked for support yet.

Detection of 15 N-labeled metabolites in microbial extracts using AI-designed broadband pulses for 1 H, 15 N heteronuclear NMR spectroscopy

Open access
V.S., Manu, Tonelli, Marco, Bell, Bailey, Sharma, Alok K., Bugni, Tim S., Veglia, Gianluigi · 2025 · The Analyst

Abstract

New AI-designed RF pulses increase bandwidth and sensitivity for 1 H- 15 N HSQC spectra of metabolites.

Overview

CoChat Summary

TL;DR

An AI-designed broadband 15N universal 180° pulse (UR33) used for both inversion and refocusing in 2D 1H-15N HSQC improves sensitivity for 15N-labeled metabolites, covering ~400 ppm 15N bandwidth. In crude *Micromonospora* sp. WMMC264 extracts, the UR33 sequence gave up to 286–288% maximum sensitivity gains over a hard-pulse/adiabatic sequence and 133–175% over a CHIRP-based sequence.

Key findings

  • The UR33 pulse covers ~400 ppm 15N bandwidth, compared with ~200 ppm for hard pulses and ~300 ppm for CHIRP/composite CHIRP pulses; its duration is approximately one-third that of the composite CHIRP pulse.
  • For the 0.8 mM NRASQ61R-GTP protein sample, the bbhsqcetf3gpsi2.3 sequence showed an increase of approximately 50% compared to bbhsqcetf3gpsi2.2 and an average increase of about 25% compared to bbhsqcetf3gpsi2.1.
  • In crude extracts cultured without Fe(III), bbhsqcetf3gpsi2.3 yielded a maximum sensitivity enhancement of 286% and an average gain of 62% compared to bbhsqcetf3gpsi2.1; maximum and average gains over bbhsqcetf3gpsi2.2 were 133% and 31%, respectively.
  • In crude extracts cultured with Fe(III), bbhsqcetf3gpsi2.3 showed a maximum sensitivity gain of 288% and an average gain of 77% compared to bbhsqcetf3gpsi2.1; maximum and average gains over bbhsqcetf3gpsi2.2 were 175% and 34%, respectively.

Methods

  • GENETICS-AI was used to design the UR33 universal 180° pulse for 15N inversion and refocusing; three 2D 1H,15N BB-HSQC sequences were compared: bbhsqcetf3gpsi2.1 (hard refocusing + HypSec.500 inversion), bbhsqcetf3gpsi2.2 (CHIRP Crp20,1,40.1 inversion + composite CHIRP Crp60comp.4 refocusing), and bbhsqcetf3gpsi2.3 (UR33 for both operations).
  • Samples were a 0.8 mM NRASQ61R-GTP protein (20.3 kDa) and crude extracts of *Micromonospora* sp. WMMC264 cultured in 15N-labeled ASW-A medium with or without 50 µM iron(III) sulfate; extracts were processed by C18 solid-phase extraction and resuspended in DMSO-d6.
  • NMR data were acquired at 600 MHz and 288.2 K with 16 transients, 128 dummy scans, 1.0 s relaxation delay, 768 × 310 complex points, acquisition times of 76.8 ms (1H) and 40.3 ms (15N), and total acquisition time of 3 h 8 m; data were processed with NMRPipe and compared via peak intensities I1/I2/I3.

Limitations

  • Stated: the cell extracts were solubilized in DMSO to minimize signal losses from chemical exchange in protic solvents, because nitrogen protons in metabolites are highly labile in aqueous solutions and at physiological pH; the authors propose WADE pulses for the 1H channel and state that incorporating WADE into 1H,15N BB-HSQC for water samples is a next step.
  • Evident from the text: the demonstration is limited to one protein sample (NRASQ61R-GTP) and one microbial strain (*Micromonospora* sp. WMMC264) with or without Fe(III), and the study reports signal-intensity enhancements rather than broader metabolite identification or quantification performance.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1039/d5an00074b

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 1 Not valid · 7 Not checked · 33 Own results and interpretations

20 more claims

Create a free account to see all 41 claims and to verify the 7 references still open.

See all claims — free account
  • It may state two separate claims as one. 7
  • Probably not a substantial claim. 10

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

2 of 2

Citations

Cites

Research works printed but not linked: 2

  1. Palmer, 1991, J. Magn. Reson., 93, 151
  2. Silver, 1984, J. Magn. Reson., 59, 347

Metadata

Authors
V.S., M., Tonelli, M., Bell, B., Sharma, A. K., Bugni, T. S., & Veglia, G.
Affiliations
  • Department of Biochemistry, Molecular Biology & Biophysics, University of Minnesota, Minneapolis, Minnesota 55455, USA
  • University of Wisconsin–Madison (US)
  • Frederick National Laboratory for Cancer Research (US)
  • University of Minnesota (US)
Corresponding author
Veglia, Gianluigi
Venue
The Analyst
Published
2025
Volume
150
Issue
9
Pages
1856-1861
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W4408657514
Cited by
1
References
20
Citations by year
2026: 1
FWCI
0.23
Type
journal article
Language
en
Open access
Locations
  • The Analyst (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Science Foundation (CHE-2304829)
  • University of Minnesota
  • National Institute of Health Sciences (75N91019D00024, R24GM141526)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
Keywords
nitrogen-containing metabolites, microbial extracts, biological fluids, metabolite detection
MeSH terms
Nitrogen Isotopes, Nuclear Magnetic Resonance, Biomolecular

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-17, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-17 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.