Waste to resource approach: CoFe 2 O 4 -modified spent tea waste for magnetic solid-phase extraction of toxic metal ions from water samples

Open access
Seker, Serdal, Ozdes, Duygu, Duran, Celal · 2026 · Analytical Methods

Abstract

-modified spent tea waste can be regarded as an effective, economical, and sustainable adsorbent for trace heavy metal analysis in environmental water samples, owing to its rapid extraction kinetics, high adsorption capacity, and low detection limits.

Overview

CoChat Summary

TL;DR

Spent tea waste biochar was modified with CoFe₂O₄ nanoparticles and used as a magnetic solid-phase extraction (MSPE) adsorbent for preconcentrating Cd(II), Pb(II), and Ni(II) from water prior to FAAS determination. The composite gave quantitative recoveries at pH 6.0 with a preconcentration factor of 40 and was successfully applied to mining wastewater, stream water, and organized-industrial-zone wastewater.

Key findings

  • Raising pH from 2.0 to 6.0 increased recovery from 17.6% to 98.4% for Cd(II), 57.7% to 95.2% for Pb(II), and 10.2% to 99.9% for Ni(II); pH 6.0 was optimal, with decreased recovery at pH 8.0 due to hydroxide precipitation.
  • Adsorption followed the Langmuir model (R² > 0.95), with q_max of 69.4 mg g⁻¹ (Cd), 185.2 mg g⁻¹ (Pb), and 45.2 mg g⁻¹ (Ni) for CoFe₂O₄/STWB versus 42.9, 75.8, and 16.8 mg g⁻¹ for pristine STWB.
  • Method performance: LODs of 0.35, 2.67, and 1.83 µg L⁻¹; LOQs of 1.05, 8.02, and 5.50 µg L⁻¹; RSDs of 1.98%, 3.31%, and 2.67% for Cd, Pb, and Ni respectively; PF = 40 (200 mL sample / 5.0 mL eluent).
  • Spike recoveries in real waters were 88.1–102.5% (Cd), 87.4–103.5% (Pb), and 88.0–103.0% (Ni); recoveries >90% were maintained in the presence of high concentrations of foreign ions (Na⁺, K⁺, Ca²⁺, Mg²⁺, CO₃²⁻, NO₃⁻, PO₄³⁻, SO₄²⁻, NH₄⁺, Fe(II), Mn(II), Zn(II), Hg(II)).

Methods

  • Adsorbent synthesis: spent tea waste was dried (105 °C) and pyrolyzed at 500 °C for 2 h under oxygen-limited conditions to make biochar (STWB); CoFe₂O₄ was deposited by in situ co-precipitation (Fe³⁺:Co²⁺ = 2:1, 7.0 g STWB, NaOH to pH 10–11, 80 °C), then dried at 105 °C for 6 h and calcined at 400 °C for 4 h.
  • Characterization: FTIR, SEM-EDX, XRD, and BET N₂ adsorption–desorption; metal quantification by flame atomic absorption spectrometry (PerkinElmer AAnalyst 400).
  • Batch MSPE optimization: 10 mL solutions containing 5.0 µg Cd(II), 20.0 µg Pb(II), and 10.0 µg Ni(II) with 25 mg adsorbent (2.0 g L⁻¹), pH 6.0, 1 min adsorption, magnetic/centrifugal separation, desorption with 5.0 mL of 0.2 M HCl for 1 min; parameters optimized included pH, eluent type/concentration/volume, adsorbent amount, sample volume (50–600 mL), contact time, interfering ions, isotherms, and reusability over six cycles.

Limitations

  • The paper states no explicit limitations section; the text notes that at excessively high adsorbent amounts, incomplete elution and adsorbent agglomeration may occur, and that recoveries declined when sample volume exceeded 200 mL (Cd 97.2%→89.5%, Pb 93.4%→75.1%, Ni 95.6%→80.9% from 200 to 600 mL).
  • Evident from the text: reusability without regeneration was limited — Cd efficiency fell from 99.7% (cycle 1) to 81.6% (cycle 5) and Ni from 97.9% (cycle 1) to 86.8% (cycle 2), while Pb remained at 99.6% through cycle 6.
  • Evident from the text: several sections (e.g., 3.1.3/3.1.4 characterization details, full isotherm fitting discussion) are only partially present in the supplied text, and the abstract as provided does not describe this study.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1039/d6ay00152a

Cites

57 of 60 references verified0 citation errors · 3 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

1 Valid · 0 Not valid · 9 Not checked · 65 Own results and interpretations

40 more claims

Create a free account to see all 75 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 23
  • The quote only partly states this claim. 2
  • Probably not a substantial claim. 7

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 60 references

Metadata

Authors
Seker, S., Ozdes, D., & Duran, C.
Affiliations
  • Gumushane University, Graduate School of Education, Gumushane, 29100, Türkiye
  • Gumushane University, Gumushane Vocational School, 29100, Gumushane, Türkiye
  • Karadeniz Technical University (TR)
Venue
Analytical Methods
Published
2026
Volume
18
Issue
13
Pages
2799-2811
ISSN
  • 1759-9660 (ISSN-L)
  • 1759-9679
OpenAlex
W7134256443
Cited by
1
References
60
Citations by year
2026: 1
FWCI
2.61
Type
journal article
Language
en
Open access
Locations
  • Analytical Methods (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
Gümüşhane Üniversitesi (23.E0116.07.01)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
  • Physical Sciences › Environmental Science › Water Science and Technology › Adsorption and biosorption for pollutant removal
  • Physical Sciences › Environmental Science › Water Science and Technology › Environmental and Analytical Chemistry Studies
Keywords
cobalt ferrite, magnetic solid-phase extraction, heavy metal ions, water analysis, adsorbents, waste valorization, trace metal detection, extraction kinetics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-03, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-03 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Waste to resource approach: CoFe 2 O 4 -modified spent tea waste for magnetic solid-phase extraction of toxic metal ions from water samples. https://app.cochat.ai/papers/10.1039/d6ay00152a
The paper
Seker, S., Ozdes, D., & Duran, C. (2026). Waste to resource approach: CoFe 2 O 4 -modified spent tea waste for magnetic solid-phase extraction of toxic metal ions from water samples. Analytical Methods. https://doi.org/10.1039/d6ay00152a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.