A New Method for Monitoring Deep Body Temperature from the Skin Surface
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
1. A new technique for monitoring the deep body temperature is described. The technique depends on creating a zone of zero heat-flow across the body shell; this brings the deep body temperature to the skin surface where it is measured with a simple electronic thermometer. 2. The new device gives a temperature closely comparable with other methods for measuring the deep body temperature in the resting subject, and is simple to use and socially acceptable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new technique for monitoring the deep body temperature in man from the intact skin surface.
Fox, R. H., & Solman, A. (1971) · PubMed · Cited by 179
Self-citationCOMPARISON OF INTRACARDIAC AND INTRAVASCULAR TEMPERATURES WITH RECTAL TEMPERATURES IN MAN 12
Eichna, L. W., Berger, A. R., RADER, B., & Becker, W. H. (1951) · Journal of Clinical Investigation · doi:10.1172/jci102451 · Cited by 116
Temperature in the external auditory meatus as an index of central temperature changes
Cooper, K. E., Cranston, W. I., & Snell, E. S. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.5.1032 · Cited by 96
The effect of exercise on temperature regulation
Bradbury, P. A., Fox, R. H., Goldsmith, R. S., & Hampton, I. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007384 · Cited by 42
Self-citationDIAGNOSIS OF ACCIDENTAL HYPOTHERMIA OF THE ELDERLY
Fox, R. H., Fry, A. J., Woodward, P., Collins, J. C., & Macdonald, I. C. (1971) · The Lancet · doi:10.1016/s0140-6736(71)92414-7 · Cited by 41
Self-citationELEVATION OF BODY TEMPERATURE IN HEALTH
Minard, D., Copman, L., & Dasler, A. R. (1964) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1964.tb13680.x · Cited by 32
A thermoregulatory function test using controlled hyperthermia.
Fox, R. H., Crockford, G. W., Hampton, I., & MacGibbon, R. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.23.2.267 · Cited by 23
Self-citationELEVATION OF BODY TEMPERATURE IN DISEASE
Atkins, E. (1964) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1964.tb13681.x · Cited by 15
Cited by
Temperature Monitoring and Perioperative Thermoregulation
Sessler, D. I., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31817f6d76 · Cited by 758
“An interesting method of measuring core temperature from the surface of the skin is to use a system originally proposed by Fox et al.17,18 and refined by Togawa et al.19 The technique is to combine a heater with a thermal flux transducer (which is, effectively, two thermometers separated by a known thermal insulator).”
MethodHeat Flow and Distribution during Induction of General Anesthesia
Matsukawa, T., Sessler, D. I., Sessler, A. M., Schroeder, M., Ozaki, M., Kurz, A., & Cheng, C. (1995) · Anesthesiology · doi:10.1097/00000542-199503000-00008 · Cited by 528
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
Heat Flow and Distribution during Epidural Anesthesia
Matsukawa, T., Sessler, D. I., Christensen, R., Ozaki, M., & Schroeder, M. (1995) · Anesthesiology · doi:10.1097/00000542-199511000-00008 · Cited by 290
Optimal Duration and Temperature of Prewarming
Sessler, D. I., Schroeder, M., Merrifield, B., Matsukawa, T., & Cheng, C. (1995) · Anesthesiology · doi:10.1097/00000542-199503000-00009 · Cited by 208
Unique Aspects of the Elderly Surgical Population: An Anesthesiologist’s Perspective
Yang, R., Wolfson, M., & Lewis, M. C. (2011) · Geriatric Orthopaedic Surgery & Rehabilitation · doi:10.1177/2151458510394606 · Cited by 166
An Evaluation of a Zero-Heat-Flux Cutaneous Thermometer in Cardiac Surgical Patients
Eshraghi, Y., Nasr, V., Parra-Sanchez, I., Van Duren, A., Botham, M., Santoscoy, T., & Sessler, D. I. (2014) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000319 · Cited by 161
Thermometry and interpretation of body temperature
Chen, W. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00102-2 · Cited by 72
Mäkinen, M.-T., Pesonen, A., Jousela, I., Päivärinta, J., Poikajärvi, S., Albäck, A., Salminen, U.-S., & Pesonen, E. (2016) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2016.03.141 · Cited by 69
Evaluation of the Temple Touch Pro, a Novel Noninvasive Core-Temperature Monitoring System
Evron, S., Weissman, A., Toivis, V., Shahaf, D. B., You, J., Sessler, D. I., & Ezri, T. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001695 · Cited by 38
Accuracy of Zero-Heat-Flux Cutaneous Temperature in Intensive Care Adults
Dahyot-Fizelier, C., Lamarche, S., Kerforne, T., Bénard, T., Giraud, B., Bellier, R., Carise, E., Frasca, D., & Mimoz, O. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002317 · Cited by 34
Potential tissue damage from transcutaneous recharge of neuromodulation implants
Lovik, R. D., Abraham, J. P., & Sparrow, E. M. (2009) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2009.03.010 · Cited by 29
Clothing for protection against heat and flames
Rossi, R. (2014) · Protective Clothing · doi:10.1533/9781782420408.1.70 · Cited by 17
Shourav, M. K., Salsabila, S., Lee, J.-Y., & Kim, J. K. (2021) · Biomedical Optics Express · doi:10.1364/boe.431534 · Cited by 10
Metadata
- Authors
- Fox, R. H., Solman, A. J., Isaacs, R., Fry, A. J., & MacDonald, I. C.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1973-01-01
- Volume
- 44
- Issue
- 1
- Pages
- 81-86
- ISSN
- 0301-0538 (ISSN-L)
- OpenAlex
- W147517017
- Cited by
- 168
- References
- 8
- FWCI
- 1.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.