Orthostatic Circulatory Control in the Elderly Evaluated by Non-Invasive Continuous Blood Pressure Measurement
The DOI matches its Crossref record.
Abstract
1. Continuous orthostatic responses of blood pressure and heart rate were measured in 40 healthy and active elderly subjects over 70 years of age in order to assess the time course and rapidity of orthostatic cardiovascular adaptation in old age. 2. During the first 30 s (initial phase) the effects of active standing and passive head-up tilt closely resembled those observed earlier in younger age groups. Standing up was accompanied by a drop (mean ± SD) in systolic and diastolic blood pressures of 26 ± 13 mmHg and 12 ± 18 mmHg, respectively, at around 10 s, and a subsequent rise up to 11 ± 17 mmHg and 8 ± 6 mmHg above supine values at around 20 s. The drop in blood pressure upon standing was accompanied by a transient increase in heart rate with a maximum of 13 beats/min, followed by a gradual decrease to 7 beats/min above supine levels. These characteristic transient changes were absent upon a passive head-up tilt. 3. After 1–2 min of standing (early steady-state phase) diastolic blood pressure and heart rate increased significantly after active and passive postural changes. On average, for all subjects systolic blood pressure tended to increase from control during 5–10 min standing, reaching a significant difference at 10 min. During standing, the largest increases in systolic blood pressure were found in subjects with the lowest supine blood pressures. 4. In conclusion, for the investigation of orthostatic circulatory responses in elderly subjects the following factors have to be taken into account: active versus passive changes in posture, the timing of the blood pressure reading, and the level of supine blood pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Self-citationInitial orthostatic hypotension: review of a forgotten condition
Wieling, W., Krediet, C. T. P., van Dijk, N., Linzer, M., & Tschakovsky, M. E. (2007) · Clinical Science · doi:10.1042/cs20060091 · Cited by 374
Self-citationvan Lieshout, J. J., Wieling, W., Karemaker, J. M., & Eckberg, D. L. (1991) · Clinical Science · doi:10.1042/cs0810575 · Cited by 323
Self-citationNexfin Noninvasive Continuous Blood Pressure Validated Against Riva-Rocci/Korotkoff
Eeftinck Schattenkerk, D. W., van Lieshout, J. J., van den Meiracker, A. H., Wesseling, K. R., Blanc, S., Wieling, W., van Montfrans, G. A., Settels, J. J., Wesseling, K. H., & Westerhof, B. E. (2009) · American Journal of Hypertension · doi:10.1038/ajh.2008.368 · Cited by 222
Self-citationTrouern‐Trend, J. J., Cable, R. G., Badon, S. J., Newman, B. H., & Popovsky, M. A. (1999) · Transfusion · doi:10.1046/j.1537-2995.1999.39399219291.x · Cited by 208
Metadata
- Authors
- Imholz, B. P. M., Dambrink, J. H. A., Karemaker, J. M., & Wieling, W.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 1990-07-01
- Volume
- 79
- Issue
- 1
- Pages
- 73-79
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2464918250
- Cited by
- 66
- References
- 0
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Orthostatic Circulatory Control in the Elderly Evaluated by Non-Invasive Continuous Blood Pressure Measurement. https://app.cochat.ai/papers/10.1042/cs0790073
- The paper
- Imholz, B. P. M., Dambrink, J. H. A., Karemaker, J. M., & Wieling, W. (1990). Orthostatic Circulatory Control in the Elderly Evaluated by Non-Invasive Continuous Blood Pressure Measurement. Clinical Science. https://doi.org/10.1042/cs0790073
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.