CoChat

Mechanisms underlying the impairment in orthostatic tolerance after nocturnal recumbency in patients with autonomic failure

OMBONI, Stefano, SMIT, Adrianus A.J., VAN LIESHOUT, Johannes J., SETTELS, Jos J., LANGEWOUTERS, Gerard J., WIELING, Wouter · 2001 · Clinical Science
Cited by 68

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

In the present study, we have assessed in patients with neurogenic orthostatic hypotension the haemodynamics underlying the reduced tolerance to standing after prolonged recumbency at night. In 10 patients with neurogenic orthostatic hypotension (age 33-68 years), of which seven were being treated with fludrocortisone and/or sleeping in the 12° head-up tilt position, 24h continuous non-invasive finger blood pressure was recorded by a Portapres device. Beat-to-beat blood pressure, heart rate, stroke volume, cardiac output and total peripheral vascular resistance obtained by pulse contour analysis were assessed during 5min of standing in the evening (at 22.30 hours) and in the morning (at 06.30hours). On average, the inverse of the normal 24h blood pressure profile was found, with a large diversity in blood pressure profiles among patients. Supine blood pressure values were similar, but standing blood pressure values were lower in the morning than in the evening (P < 0.01). This resulted from larger falls in stroke volume and cardiac output upon standing in the morning compared with the evening, while total peripheral resistance did not change. There was no relationship between the decrease in body weight during the night (mean 0.9kg; range 0.2-1.6kg) and the evening-morning difference in standing blood pressure. We conclude that, in patients with neurogenic orthostatic hypotension, the impaired tolerance to standing in the morning is due to larger falls in stroke volume and cardiac output. Not only nocturnal polyuria, but also a redistribution of body fluid, are likely mechanisms underlying the pronounced decreases in stroke volume and cardiac output after prolonged recumbency at night.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1042/cs1010609

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
OMBONI, S., SMIT, A. A. J., VAN LIESHOUT, J. J., SETTELS, J. J., LANGEWOUTERS, G. J., & WIELING, W.
Venue
Clinical Science
Published
2001-10-29
Volume
101
Issue
6
Pages
609-618
ISSN
  • 0143-5221 (ISSN-L)
  • 1470-8736
OpenAlex
W2068425882
Cited by
68
References
4
FWCI
1.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.