Cardiac output by Modelflow® method from intra-arterial and fingertip pulse pressure profiles
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Modelflow®, when applied to non-invasive fingertip pulse pressure recordings, is a poor predictor of cardiac output (Q, litre·min-1). The use of constants established from the aortic elastic characteristics, which differ from those of finger arteries, may introduce signal distortions, leading to errors in computing Q. We therefore hypothesized that peripheral recording of pulse pressure profiles undermines the measurement of Q with Modelflow®, so we compared Modelflow® beat-by-beat Q values obtained simultaneously non-invasively from the finger and invasively from the radial artery at rest and during exercise. Seven subjects (age, 24.0±2.9 years; weight, 81.2±12.6 kg) rested, then exercised at 50 and 100 W, carrying a catheter with a pressure head in the left radial artery and the photoplethysmographic cuff of a finger pressure device on the third and fourth fingers of the contralateral hand. Pulse pressure from both devices was recorded simultaneously and stored on a PC for subsequent Q computation. The mean values of systolic, diastolic and mean arterial pressure at rest and exercise steady state were significantly (P<0.05) lower from the finger than the intra-arterial catheter. The corresponding mean steady-state Q obtained from the finger (Qporta) was significantly (P<0.05) higher than that computed from the intra-arterial recordings (Qpia). The line relating beat-by-beat Qporta and Qpia was y=1.55x-3.02 (r2=0.640). The bias was 1.44 litre·min-1 and the precision was 2.84 litre·min-1. The slope of this line was significantly higher than 1, implying a systematic overestimate of Q by Qporta with respect to Qpia. Consistent with the tested hypothesis, these results demonstrate that pulse pressure profiles from the finger provide inaccurate absolute Q values with respect to the radial artery, and therefore cannot be used without correction with a calibration factor calculated previously by measuring Q with an independent method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“However, there is ongoing discussion in the literature in regard to the accuracy of PPG-based cardiac output assessments (Azabji Kenfack et al 2004).”
BackgroundNon‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Alian, A. A., & Shelley, K. H. (2014) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2014.08.006 · Cited by 289
Monitoring of peri‐operative fluid administration by individualized goal‐directed therapy
Bundgaard‐Nielsen, M., Holte, K., Secher, N. H., & Kehlet, H. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2006.01221.x · Cited by 250
“Changes in SV measured with MF have been validated against other modalities (50, 51, 53, 54).”
MethodEvaluation of stroke volume estimation during orthostatic stress: the utility of Modelflow
Lucci, V.-E. M., Parsons, I. T., Hockin, B. C. D., & Claydon, V. E. (2023) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000671 · Cited by 12
“It is not possible to determine from these data whether this reflects overestimation by Modelflow [22], underestimation by echocardiography [23], or some combination of these possibilities.”
Background
Metadata
- Authors
- KENFACK, M. A., LADOR, F., LICKER, M., MOIA, C., TAM, E., CAPELLI, C., MOREL, D., & FERRETTI, G.
- Venue
- Clinical Science
- Publisher
- Portland Press Ltd.
- Published
- 2004-04-01
- Volume
- 106
- Issue
- 4
- Pages
- 365-369
- ISSN
- 0143-5221 (ISSN-L)
- 1470-8736
- OpenAlex
- W2017971482
- Cited by
- 79
- References
- 1
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac output by Modelflow® method from intra-arterial and fingertip pulse pressure profiles. https://app.cochat.ai/papers/10.1042/cs20030303
- The paper
- KENFACK, M. A., LADOR, F., LICKER, M., MOIA, C., TAM, E., CAPELLI, C., MOREL, D., & FERRETTI, G. (2004). Cardiac output by Modelflow® method from intra-arterial and fingertip pulse pressure profiles. Clinical Science. https://doi.org/10.1042/cs20030303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.