Cited by 289Non-Invasive Vital Sign MonitoringHemodynamic Monitoring and TherapyCardiovascular Health and Disease Prevention

Photoplethysmography

Alian, Aymen A., Shelley, Kirk H.·2014·Best Practice & Research Clinical Anaesthesiology

Abstract

The photoplethysmographic (PPG) waveform, also known as the pulse oximeter waveform, is one of the most commonly displayed clinical waveforms. First described in the 1930s, the technology behind the waveform is simple. The waveform, as displayed on the modern pulse oximeter, is an amplified and highly filtered measurement of light absorption by the local tissue over time. It is optimized by medical device manufacturers to accentuate its pulsatile components. Physiologically, it is the result of a complex, and not well understood, interaction between the cardiovascular, respiratory, and autonomic systems. All modern pulse oximeters extract and display the heart rate and oxygen saturation derived from the PPG measurements at multiple wavelengths. "As is," the PPG is an excellent monitor for cardiac arrhythmia, particularly when used in conjunction with the electrocardiogram (ECG). With slight modifications in the display of the PPG (either to a strip chart recorder or slowed down on the monitor screen), the PPG can be used to measure the ventilator-induced modulations which have been associated with hypovolemia. Research efforts are under way to analyze the PPG using improved digital signal processing methods to develop new physiologic parameters. It is hoped that when these new physiologic parameters are combined with a more modern understanding of cardiovascular physiology (functional hemodynamics) the potential utility of the PPG will be expanded. The clinical researcher's objective is the use of the PPG to guide early goal-directed therapeutic interventions (fluid, vasopressors, and inotropes), in effect to extract from the simple PPG the information and therapeutic guidance that was previously only obtainable from an arterial pressure line and the pulmonary artery catheter.

Integrity signals

Registry

Crossref · 10.1016/j.bpa.2014.08.006

Cites

83 of 83 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Alian, A. A., & Shelley, K. H.
Affiliations
Yale University (US)
Corresponding author
Shelley, Kirk H.
Venue
Best Practice & Research Clinical Anaesthesiology
Publisher
Elsevier BV
Published
2014-12
Volume
28
Issue
4
Pages
395-406
ISSN
  • 1521-6896 (ISSN-L)
  • 1753-3740
OpenAlex
W4245509891
Cited by
289
References
83
Citations by year
2026: 18 · 2025: 45 · 2024: 36 · 2023: 44 · 2022: 37 · 2021: 25 · 2020: 20 · 2019: 21 · 2018: 17 · 2017: 8 · 2016: 7 · 2015: 9 · 2012: 1
FWCI
4.15
Type
journal article
Language
en
Open access
closed
Locations
  • Best practice & research. Clinical anaesthesiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
photoplethysmography, pulse oximetry, arrhythmia monitoring, oxygen saturation, heart rate, hypovolemia, early goal-directed therapy, fluid management, vasopressors, inotropic agents
MeSH terms
Hemodynamics, Humans, Oximetry, Photoplethysmography, Hypovolemia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›