Automatic Estimation of Laryngeal Vestibule Closure Duration Using High-Resolution Cervical Auscultation Signals
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Purpose: Safe swallowing requires adequate protection of the airway to prevent swallowed materials from entering the trachea or lungs (i.e., aspiration). Laryngeal vestibule closure (LVC) is the first line of defense against swallowed materials entering the airway. Absent LVC or mistimed/shortened closure duration can lead to aspiration, adverse medical consequences, and even death. LVC mechanisms can be judged commonly through the videofluoroscopic swallowing study; however, this type of instrumentation exposes patients to radiation and is not available or acceptable to all patients. There is growing interest in noninvasive methods to assess/monitor swallow physiology. In this study, we hypothesized that our noninvasive sensor-based system, which has been shown to accurately track hyoid displacement and upper esophageal sphincter opening duration during swallowing, could predict laryngeal vestibule status, including the onset of LVC and the onset of laryngeal vestibule reopening, in real time and estimate the closure duration with a comparable degree of accuracy as trained human raters. Method: The sensor-based system used in this study is high-resolution cervical auscultation (HRCA). Advanced machine learning techniques enable HRCA signal analysis through feature extraction and complex algorithms. A deep learning model was developed with a data set of 588 swallows from 120 patients with suspected dysphagia and further tested on 45 swallows from 16 healthy participants. Results: The new technique achieved an overall mean accuracy of 74.90% and 75.48% for the two data sets, respectively, in distinguishing LVC status. Closure duration ratios between automated and gold-standard human judgment of LVC duration were 1.13 for the patient data set and 0.93 for the healthy participant data set. Conclusions: This study found that HRCA signal analysis using advanced machine learning techniques can effectively predict laryngeal vestibule status (closure or opening) and further estimate LVC duration. HRCA is potentially a noninvasive tool to estimate LVC duration for diagnostic and biofeedback purposes without X-ray imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuroplasticity Subserving Motor Skill Learning
Dayan, E., & Cohen, L. G. (2011) · Neuron · doi:10.1016/j.neuron.2011.10.008 · Cited by 1,408
Methodology for detecting swallowing sounds
Takahashi, K., Groher, M., & Michi, K.-I. (1994) · Dysphagia · doi:10.1007/bf00262760 · Cited by 215
Test-retest variability in normal swallowing
Lof, G. L., & Robbins, J. (1990) · Dysphagia · doi:10.1007/bf02407271 · Cited by 133
Detection of Swallowing Sounds: Methodology Revisited
Cichero, J. A. Y., & Murdoch, B. E. (2002) · Dysphagia · doi:10.1007/s00455-001-0100-x · Cited by 97
Bonilha, H. S., Humphries, K., Blair, J., Hill, E. G., McGrattan, K., Carnes, B., Huda, W., & Martin-Harris, B. (2013) · Dysphagia · doi:10.1007/s00455-012-9415-z · Cited by 90
Effects of liquid stimuli on dual-axis swallowing accelerometry signals in a healthy population
Lee, J., Sejdić, E., Steele, C. M., & Chau, T. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-7 · Cited by 68
Self-citationA statistical analysis of cervical auscultation signals from adults with unsafe airway protection
Dudik, J. M., Kurosu, A., Coyle, J. L., & Sejdić, E. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-015-0110-9 · Cited by 42
Self-citationKurosu, A., Coyle, J. L., Dudik, J. M., & Sejdic, E. (2019) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2018.05.038 · Cited by 33
Self-citation
Cited by
Donohue, C., Khalifa, Y., Perera, S., Sejdić, E., & Coyle, J. L. (2021) · Dysphagia · doi:10.1007/s00455-020-10177-0 · Cited by 41
Self-citationDonohue, C., Khalifa, Y., Mao, S., Perera, S., Sejdić, E., & Coyle, J. L. (2021) · Journal of Speech, Language, and Hearing Research · doi:10.1044/2021_jslhr-21-00134 · Cited by 15
“…our lab’s patient data set (e.g., patients with suspected dysphagia who underwent VFSSs): UES opening onset, UES closure onset, LVC onset, LV reopening onset, and hyoid frame-by-frame tracking (Donohue et al., 2020, 2020a; Khalifa et al., 2021a, 2021b; Mao et al., 2019, 2021; Sabry et al., 2020).”
BackgroundSelf-citationDonohue, C., Khalifa, Y., Mao, S., Perera, S., Sejdić, E., & Coyle, J. L. (2022) · Dysphagia · doi:10.1007/s00455-021-10317-0 · Cited by 12
Self-citationArtificial intelligence in the diagnosis and management of dysphagia: a scoping review
Silva, R. D. D., Almeida, S. B., Gonçalves, F. M., Zeigelboim, B. S., Stechman-Neto, J., Schroder, A. G. D., Nascimento, W. V., Santos, R. S., & Araujo, C. M. D. (2025) · CoDAS · doi:10.1590/2317-1782/e20240305en · Cited by 6
Metadata
- Authors
- Sabry, A., Mahoney, A. S., Mao, S., Khalifa, Y., Sejdić, E., & Coyle, J. L.
- Venue
- Perspectives of the ASHA Special Interest Groups
- Published
- 2020-12-17
- Volume
- 5
- Issue
- 6
- Pages
- 1647-1656
- ISSN
- 2381-473X (ISSN-L)
- 2381-4764
- OpenAlex
- W3111108096
- Cited by
- 18
- References
- 8
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic Estimation of Laryngeal Vestibule Closure Duration Using High-Resolution Cervical Auscultation Signals. https://app.cochat.ai/papers/10.1044/2020_persp-20-00073
- The paper
- Sabry, A., Mahoney, A. S., Mao, S., Khalifa, Y., Sejdić, E., & Coyle, J. L. (2020). Automatic Estimation of Laryngeal Vestibule Closure Duration Using High-Resolution Cervical Auscultation Signals. Perspectives of the ASHA Special Interest Groups. https://doi.org/10.1044/2020_persp-20-00073
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.