Speech Recognition as a Function of the Number of Electrodes Used in the SPEAK Cochlear Implant Speech Processor
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Speech recognition was measured in listeners with the Nucleus-22 SPEAK speech processing strategy as a function of the number of electrodes. Speech stimuli were analyzed into 20 frequency bands and processed according to the usual SPEAK processing strategy. In the normal clinical processor each electrode is assigned to represent the output of one filter. To create reduced-electrode processors the output of several adjacent filters were directed to a single electrode, resulting in processors with 1, 2, 4, 7, 10, and 20 electrodes. The overall spectral bandwidth was preserved, but the number of active electrodes was progressively reduced. After a 2-day period of adjustment to each processor, speech recognition performance was measured on medial consonants, vowels, monosyllabic words, and sentences. Performance with a single electrode processor was poor in all listeners, and average performance increased dramatically on all test materials as the number of electrodes was increased from 1 to 4. No differences in average performance were observed on any test in the 7-, 10-, and 20-electrode conditions. On sentence and consonant tests there was no difference between average performance with the 4-electrode and 20-electrode processors. This pattern of results suggests that cochlear implant listeners are not able to make full use of the spectral information on all 20 electrodes. Further research is necessary to understand the reasons for this limitation and to understand how to increase the amount of spectral information in speech received by implanted listeners.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Speech Recognition with Primarily Temporal Cues
Shannon, R. V., Zeng, F.-G., Kamath, V., Wygonski, J., & Ekelid, M. (1995) · Science · doi:10.1126/science.270.5234.303 · Cited by 3,024
Self-citationAn Analysis of Perceptual Confusions Among Some English Consonants
Miller, G. A., & Nicely, P. E. (1955) · The Journal of the Acoustical Society of America · doi:10.1121/1.1907526 · Cited by 1,869
Better speech recognition with cochlear implants
Wilson, B. S., Finley, C. C., Lawson, D. T., Wolford, R. D., Eddington, D. K., & Rabinowitz, W. M. (1991) · Nature · doi:10.1038/352236a0 · Cited by 1,190
Temporal information in speech: acoustic, auditory and linguistic aspects
Rosen, S. (1992) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1992.0070 · Cited by 1,130
Speech perception without traditional speech cues
Remez, R. E., Rubin, P. E., Pisoni, D. B., & Carrell, T. D. (1981) · Science · doi:10.1126/science.7233191 · Cited by 800
Auditory Prostheses Research with Multiple Channel Intracochlear Stimulation in Man
Eddington, D. K., Dobelle, W. H., Mladejovsky, M. G., Brackmann, D. E., & Parkin, J. L. (1978) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/00034894780870s602 · Cited by 334
Speech waveform envelope cues for consonant recognition
Van Tasell, D. J., Soli, S. D., Kirby, V. M., & Widin, G. P. (1987) · The Journal of the Acoustical Society of America · doi:10.1121/1.395251 · Cited by 292
Skinner, M. W., Clark, G. M., Whitford, L. A., Seligman, P., Staller, S. J., Shipp, D. B., Shallop, J. K., Everingham, C., Menapace, C., & Arndt, P. L. (1994) · PubMed · Cited by 276
Cochlear Implants in Adults and Children
Gates, G. A. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530240065043 · Cited by 211
Tyler, R. S., Abbas, P., Tye‐Murray, N., Gantz, B. J., Knutson, J. F., Mccabe, B. F., Lansing, C., Brown, C., Woodworth, G., Hinrichs, J., et al. (1988) · The Laryngoscope · doi:10.1288/00005537-198810000-00013 · Cited by 204
Speech recognition with altered spectral distribution of envelope cues
Shannon, R. V., Zeng, F.-G., & Wygonski, J. (1998) · The Journal of the Acoustical Society of America · doi:10.1121/1.423774 · Cited by 193
Self-citationSpeech recognition with altered spectral distribution of envelope cues
Shannon, R. V., Zeng, F.-G., & Wygonski, J. (1996) · The Journal of the Acoustical Society of America · doi:10.1121/1.417043 · Cited by 169
Self-citationAn advanced multiple channel cochlear implant
McDermott, H. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32112 · Cited by 81
Dorman, M. F., Dankowski, K., McCandless, G. A., & Smith, L. M. (1989) · Ear and Hearing · doi:10.1097/00003446-198910000-00003 · Cited by 43
Cited by
Friesen, L. M., Shannon, R. V., Baskent, D., & Wang, X. (2001) · The Journal of the Acoustical Society of America · doi:10.1121/1.1381538 · Cited by 1,049
Self-citationCochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“parameters and signal processing on cochlear implant performance [70], [71].”
BackgroundCochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Gantz, B. J., Turner, C., Gfeller, K. E., & Lowder, M. W. (2005) · The Laryngoscope · doi:10.1097/01.mlg.0000157695.07536.d2 · Cited by 502
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Metadata
- Authors
- Fishman, K. E., Shannon, R. V., & Slattery, W. H.
- Venue
- Journal of Speech, Language, and Hearing Research
- Published
- 1997-10
- Volume
- 40
- Issue
- 5
- Pages
- 1201-1215
- ISSN
- 1092-4388 (ISSN-L)
- 1558-9102
- OpenAlex
- W2091572759
- Cited by
- 380
- References
- 14
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.