CoChat

An advanced multiple channel cochlear implant

McDermott, H. · 1989 · IEEE Transactions on Biomedical Engineering
Cited by 81

The DOI matches its Crossref record.

Abstract

An advanced multiple channel cochlear implant hearing prosthesis is described. Stimulation is presented through an array of 20 electrodes located in the scala tympani. Any two electrodes can be configured as a bipolar pair to conduct a symmetrical, biphasic, constant-current pulsatile stimulus. Up to three stimuli can be presented in rapid succession or effectively simultaneously. For simultaneous stimulation, a novel time-division current multiplexing technique has been developed to obviate electrode interactions that may compromise safety. The stimuli are independently controllable in current amplitude, duration, and onset time. Groups of three stimuli can be generated at a rate of typically 500 Hz. Stimulus control data and power are conveyed to the implant through a single transcutaneous inductive link. The device also incorporates a telemetry system that enables electrode voltage waveforms to be monitored externally in real time. The electronics of the implant are contained almost entirely on a custom designed integrated circuit. Preliminary results obtained with the first patient to receive the advanced implant are included.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/10.32112

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 81

Metadata

Authors
McDermott, H.
Venue
IEEE Transactions on Biomedical Engineering
Published
1989-07
Volume
36
Issue
7
Pages
789-797
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2078489374
Cited by
81
References
0
FWCI
0.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An advanced multiple channel cochlear implant. https://app.cochat.ai/papers/10.1109/10.32112
The paper
McDermott, H. (1989). An advanced multiple channel cochlear implant. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.32112

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.