An advanced multiple channel cochlear implant
The DOI matches its Crossref record.
Abstract
An advanced multiple channel cochlear implant hearing prosthesis is described. Stimulation is presented through an array of 20 electrodes located in the scala tympani. Any two electrodes can be configured as a bipolar pair to conduct a symmetrical, biphasic, constant-current pulsatile stimulus. Up to three stimuli can be presented in rapid succession or effectively simultaneously. For simultaneous stimulation, a novel time-division current multiplexing technique has been developed to obviate electrode interactions that may compromise safety. The stimuli are independently controllable in current amplitude, duration, and onset time. Groups of three stimuli can be generated at a rate of typically 500 Hz. Stimulus control data and power are conveyed to the implant through a single transcutaneous inductive link. The device also incorporates a telemetry system that enables electrode voltage waveforms to be monitored externally in real time. The electronics of the implant are contained almost entirely on a custom designed integrated circuit. Preliminary results obtained with the first patient to receive the advanced implant are included.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“stimulator [81], [94]–[96].”
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Wang, G., Liu, W., Sivaprakasam, M., & Kendir, G. A. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.852923 · Cited by 435
Fishman, K. E., Shannon, R. V., & Slattery, W. H. (1997) · Journal of Speech, Language, and Hearing Research · doi:10.1044/jslhr.4005.1201 · Cited by 380
Ghovanloo, M., & Najafi, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.839797 · Cited by 137
Metadata
- Authors
- McDermott, H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1989-07
- Volume
- 36
- Issue
- 7
- Pages
- 789-797
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2078489374
- Cited by
- 81
- References
- 0
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An advanced multiple channel cochlear implant. https://app.cochat.ai/papers/10.1109/10.32112
- The paper
- McDermott, H. (1989). An advanced multiple channel cochlear implant. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/10.32112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.