Design and characterization of a DNA‐encoded, voltage‐sensitive fluorescent protein
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Optical imaging of electrical activity has been suggested as a promising approach to investigate the multineuronal representation of information processing in brain tissue. While considerable progress has been made in the development of instrumentation suitable for high‐speed imaging, intrinsic or extrinsic dye‐mediated optical signals are often of limited use due to their slow response dynamics, low effective sensitivity, toxicity or undefined cellular origin. Protein‐based and DNA‐encoded voltage sensors could overcome these limitations. Here we report the design and generation of a voltage‐sensitive fluorescent protein (VSFP) consisting of a voltage sensing domain of a potassium channel and a pair of cyan and yellow emitting mutants of green fluorescent protein (GFP). In response to a change in transmembrane voltage, the voltage sensor alters the amount of fluorescence resonance energy transfer (FRET) between the pair of GFP mutants. The optical signals respond in the millisecond time‐scale of fast electrical signalling and are large enough to allow monitoring of voltage changes at the single cell level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Circular permutation and receptor insertion within green fluorescent proteins
Baird, G. S., Zacharias, D. A., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.20.11241 · Cited by 961 · cited 2×
“, 1999; Pollok & Heim, 1999) or by circular permuted GFP variants that are sensitive to conformational perturbations at their new fusion sites (Baird et al., 1999).”
BackgroundDynamic and quantitative Ca 2+ measurements using improved cameleons
Miyawaki, A., Griesbeck, O., Heim, R., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.5.2135 · Cited by 823
Green Fluorescent Protein as a Noninvasive Intracellular pH Indicator
Kneen, M., Farinas, J., Li, Y., & Verkman, A. S. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77870-1 · Cited by 712 · cited 3×
“In general, GFP-based probes of environmental factors suffer from the intrinsic dependence of GFP mutants on local pH and, in the case of some YFP variants, on halide ion concentration (Kneen et al., 1998; Jayaraman et al., 2000).”
BackgroundStructural Rearrangements Underlying K + -Channel Activation Gating
Perozo, E., Marien, D., Cortes, & Cuello, L. G. (1999) · Science · doi:10.1126/science.285.5424.73 · Cited by 552 · cited 1×
“…a property that can be achieved by ¯uorescence resonance energy transfer (FRET) between pairs of GFP (Romoser et al., 1997; Miyawaki et al., 1999; Pollok & Heim, 1999) or by circular permuted GFP variants that are sensitive to conformational perturbations at their new fusion sites (Baird et…”
BackgroundCortex-restricted disruption of NMDAR1 impairs neuronal patterns in the barrel cortex
Iwasato, T., Datwani, A., Wolf, A. M., Nishiyama, H., Taguchi, Y., Tonegawa, S., Knöpfel, T., Erzurumlu, R. S., & Itohara, S. (2000) · Nature · doi:10.1038/35021059 · Cited by 495 · cited 1×
“In whole tissue, such as acute brain slices or in vivo, signals obtained with di-4-ANNEPS are reduced by at least one order of magnitude (Iwasato et al., 2000).”
BackgroundSelf-citationUsing GFP in FRET-based applications
Pollok, B. (1999) · Trends in Cell Biology · doi:10.1016/s0962-8924(98)01434-2 · Cited by 480 · cited 1×
“…a property that can be achieved by ¯uorescence resonance energy transfer (FRET) between pairs of GFP (Romoser et al., 1997; Miyawaki et al., 1999; Pollok & Heim, 1999) or by circular permuted GFP variants that are sensitive to conformational perturbations at their new fusion sites (Baird et…”
BackgroundAtomic scale movement of the voltage-sensing region in a potassium channel measured via spectroscopy
Cha, A., Snyder, G. E., Selvin, P. R., & Bezanilla, F. (1999) · Nature · doi:10.1038/45552 · Cited by 473 · cited 1×
“A change in transmembrane voltage causes S4 to rotate, which results in a net displacement of positive charge along the direction of the electric ®eld (Cha et al., 1999; Glauner et al., 1999; Sansom, 2000).”
BackgroundA Genetically Encoded Optical Probe of Membrane Voltage
Siegel, M. S., & Isacoff, E. Y. (1997) · Neuron · doi:10.1016/s0896-6273(00)80955-1 · Cited by 430 · cited 1×
“A related concept was recently implemented by the generation of the fusion protein FlaSh that monitors C-type inactivation of an insect potassium channel (Siegel & Isacoff, 1997).”
MethodRomoser, V. A., Hinkle, P. M., & Persechini, A. (1997) · Journal of Biological Chemistry · doi:10.1074/jbc.272.20.13270 · Cited by 396 · cited 3×
“…sensitive protein domain was fused between a GFP mutant acting as donor and a second GFP mutant acting as the acceptor in such a way that a change in the conformation of the sensing domain directly modulated FRET ef®ciency (Romoser et al., 1997; Miyawaki et al., 1999; Pearce et al., 2000).”
BackgroundSpectra, membrane binding, and potentiometric responses of new charge shift probes
Fluhler, E., Burnham, V. G., & Loew, L. M. (1985) · Biochemistry · doi:10.1021/bi00342a010 · Cited by 387
Crystal structure of the tetramerization domain of the Shaker potassium channel
Kreusch, A., Pfaffinger, P. J., Stevens, C. F., & Choe, S. (1998) · Nature · doi:10.1038/31978 · Cited by 310
Spectroscopic mapping of voltage sensor movement in the Shaker potassium channel
Glauner, K. S., Mannuzzu, L. M., Gandhi, C. S., & Isacoff, E. Y. (1999) · Nature · doi:10.1038/45561 · Cited by 282
Mechanism and cellular applications of a green fluorescent protein-based halide sensor
Jayaraman, S., Haggie, P., Wachter, R. M., Remington, S. J., & Verkman, A. S. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.275.9.6047 · Cited by 264 · cited 3×
“, 1998) or halide ion concentration (Jayaraman et al., 2000) or are based on the fusion of a GFP-based reporter to a second protein that transduces environmental factors into conformational changes.”
BackgroundGrinvald, A., Manker, A., & Segal, M. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014453 · Cited by 240 · cited 2×
“Voltage-sensitive ̄uorescent dyes capable of monitoring fast electrical signalling of nerve cells have been known for many years (Salzberg et al., 1973; Grinvald et al., 1982).”
BackgroundOptical Recording of Impulses in Individual Neurones of an Invertebrate Central Nervous System
SALZBERG, B. M., DAVILA, H. V., & COHEN, L. B. (1973) · Nature · doi:10.1038/246508a0 · Cited by 240 · cited 2×
“Voltage-sensitive ̄uorescent dyes capable of monitoring fast electrical signalling of nerve cells have been known for many years (Salzberg et al., 1973; Grinvald et al., 1982).”
BackgroundRole of metallothionein in nitric oxide signaling as revealed by a green fluorescent fusion protein
Pearce, L. L., Gandley, R. E., Han, W., Wasserloos, K., Stitt, M., Kanai, A. J., McLaughlin, M. K., Pitt, B. R., & Levitan, E. S. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.1.477 · Cited by 230 · cited 4×
“…sensitive protein domain was fused between a GFP mutant acting as donor and a second GFP mutant acting as the acceptor in such a way that a change in the conformation of the sensing domain directly modulated FRET ef®ciency (Romoser et al., 1997; Miyawaki et al., 1999; Pearce et al., 2000).”
BackgroundInfluentialProperties of Kv2.1 K+ channels expressed in transfected mammalian cells.
Shi, G., Kleinklaus, A. K., Marrion, N. V., & Trimmer, J. S. (1994) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)31640-x · Cited by 123
Identification of Neural Circuits by Imaging Coherent Electrical Activity with FRET-Based Dyes
Cacciatore, T. W., Brodfuehrer, P. D., González, J. E., Jiang, T., Adams, S., Tsien, R. Y., Kristan, W. B., & Kleinfeld, D. (1999) · Neuron · doi:10.1016/s0896-6273(00)80799-0 · Cited by 95
Cited by
Creating new fluorescent probes for cell biology
Zhang, J., Campbell, R. E., Ting, A. Y., & Tsien, R. Y. (2002) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm976 · Cited by 1,981
Fluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375
All-optical electrophysiology in mammalian neurons using engineered microbial rhodopsins
Hochbaum, D. R., Zhao, Y., Farhi, S. L., Klapoetke, N., Werley, C. A., Kapoor, V., Zou, P., Kralj, J. M., Maclaurin, D., Smedemark-Margulies, N., et al. (2014) · Nature Methods · doi:10.1038/nmeth.3000 · Cited by 770
Genetic Dissection of Neural Circuits
Luo, L., Callaway, E. M., & Svoboda, K. (2008) · Neuron · doi:10.1016/j.neuron.2008.01.002 · Cited by 756
Improving FRET dynamic range with bright green and red fluorescent proteins
Lam, A. J., St-Pierre, F., Gong, Y., Marshall, J. D., Cranfill, P. J., Baird, M. A., McKeown, M. R., Wiedenmann, J., Davidson, M. W., Schnitzer, M. J., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2171 · Cited by 732
Metadata
- Authors
- Sakai, R., Repunte‐Canonigo, V., Raj, C. D., & Knöpfel, T.
- Venue
- European Journal of Neuroscience
- Publisher
- Wiley
- Published
- 2001-06
- Volume
- 13
- Issue
- 12
- Pages
- 2314-2318
- ISSN
- 0953-816X (ISSN-L)
- 1460-9568
- OpenAlex
- W1990030517
- Cited by
- 229
- References
- 18
- FWCI
- 6.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.