The motor unit potential distribution over the skin surface and its use in estimating the motor unit location
The DOI matches its Crossref record.
Abstract
The amplitude of a surface electromyogram is dependent on the number of active motor units, their size and the relative position of the recording electrode. It is not possible to interpret the surface electromyogram quantitatively without disentangling these different aspects. In this study the decline of different components of the motor unit potential with increasing radial distance from the motor unit is quantified. Fifty‐two motor units in the biceps brachii muscle were studied using 36‐channel surface electromyography combined with intramuscular scanning electromyography. Scanning electromyography was used to locate precisely the motor unit. The dependence of the surface motor unit potential magnitude on the radial distance between the motor unit and the recording electrodes can be described fairly well by an inverse power function. The steepness of this function depends on the chosen motor unit potential parameter and the interelectrode distance, but also varies between motor units. The change of the negative peak amplitude of the motor unit potential over the skin surface can be used to give a fairly accurate estimate of the location of the motor unit under the skin surface. We found that for all practical purposes the depth of a motor unit in the biceps brachii muscle can be estimated as 20% of the distance over the skin surface where motor unit potentials can be recorded with higher amplitudes than 50% of the maximal amplitude recorded at the skin surface caused by activity of the same motor unit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multichannel surface EMG: Basic aspects and clinical utility
Zwarts, M. J., & Stegeman, D. F. (2003) · Muscle & Nerve · doi:10.1002/mus.10358 · Cited by 302
Self-citationThe linear electrode array: a useful tool with many applications
Merletti, R., Farina, D., & Gazzoni, M. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00082-2 · Cited by 285
“Reprinted from [22] with permission, 1997 Scandinavian Physiological Society.”
MethodGallina, A., Disselhorst-Klug, C., Farina, D., Merletti, R., Besomi, M., Holobar, A., Enoka, R. M., Hug, F., Falla, D., Søgaard, K., et al. (2022) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2022.102656 · Cited by 77
Muceli, S., Bergmeister, K. D., Hoffmann, K.-P., Aman, M., Vukajlija, I., Aszmann, O. C., & Farina, D. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaed85 · Cited by 30
Regionalization of the stretch reflex in the human vastus medialis
Gallina, A., Blouin, J., Ivanova, T. D., & Garland, S. J. (2017) · The Journal of Physiology · doi:10.1113/jp274458 · Cited by 22
“1997), surface EMG amplitude distribution obtained with HDsEMG provides information on the position of the active motor units within a muscle (Roeleveld et al. 1997; Vieira et al. 2011; Gallina & Vieira, 2015; Gallina et al. 2016).”
BackgroundResultInfluential
Metadata
- Authors
- ROELEVELD, K., STEGEMAN, D. F., VINGERHOETS, H. M., & OOSTEROM, A. V.
- Venue
- Acta Physiologica Scandinavica
- Publisher
- Wiley
- Published
- 1997-11
- Volume
- 161
- Issue
- 4
- Pages
- 465-472
- ISSN
- 0001-6772 (ISSN-L)
- 1365-201X
- OpenAlex
- W2043350427
- Cited by
- 126
- References
- 0
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The motor unit potential distribution over the skin surface and its use in estimating the motor unit location. https://app.cochat.ai/papers/10.1046/j.1365-201x.1997.00247.x
- The paper
- ROELEVELD, K., STEGEMAN, D. F., VINGERHOETS, H. M., & OOSTEROM, A. V. (1997). The motor unit potential distribution over the skin surface and its use in estimating the motor unit location. Acta Physiologica Scandinavica. https://doi.org/10.1046/j.1365-201x.1997.00247.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.