CoChat

How reproducible is bilateral forearm plethysmography?

Open access
Petrie, John R., Ueda, Shinichiro, Morris, Andrew D., Murray, Lilian S., Elliott, Henry L., Connell, John M. C. · 1998 · British Journal of Clinical Pharmacology
Cited by 110

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Aims In studies using strain‐gauge forearm plethysmography to measure changes in forearm blood flow (FBF) during intra‐arterial infusions of vasoactive substances, measurements are often made in both arms simultaneously and the change in ratio of the infused and control arms used to express responses. However, the reproducibility of bilateral plethysmography in this setting has not been addressed in published studies. The unilateral technique remains in use, and forearm vascular resistance (FVR), an alternative method of expressing responses, is used by some investigators. We have assessed: (a) the intra‐subject variability of bilateral FBF measurements (FBF ratios) at rest, after unilateral forearm exercise, and during intra‐arterial infusions of vasoconstrictor substances; (b) whether bilateral plethysmography is more reproducible than unilateral plethysmography; and (c) the reproducibility of FVR (unilateral and bilateral). Methods Study 1 Nine healthy subjects attended 3 study days, 1 week apart. FBF was measured at rest and after 2 min of standardized unilateral forearm exercise; between‐day intra‐subject variability was expressed as coefficients of variation (CV) calculated using two‐way analysis of variance (ANOVA). Study 2 Five healthy subjects attended 2 study days when FBF was measured during incremental infusions of noradrenaline (15, 30, 150, 300 pmol min−1 ) and angiotensin II (1, 5, 10, 50 pmol min−1 ); for each individual subject at each dose intra‐subject variability was assessed using the difference between responses (percentage change from baseline) on days 1 and 2. Results Study 1 At rest, intra‐subject variability (CV) of baseline FBF ratios was 19% compared with 31% (left) and 39% (right) for unilateral FBF measurements. After ipsilateral exercise, unilateral FBF measurements were more reproducible (32 vs 17%) than FBF ratios; by 20 min after exercise, the previous pattern had been re‐established (19 vs 27%). Intra‐subject variability (CV) of baseline FVR ratio and post‐exercise FVR was 14%. Study 2 Inter‐quartile ranges of the differences between responses on days 1 and 2 (FBF ratios vs FBF) were: angiotensin II 14 vs 18%; noradrenaline 16 vs 27%. Conclusions FBF ratios are more reproducible than unilateral FBF measurements at rest (CV 19%vs 39%) and for measuring responses to intra‐arterial infusions of vasoconstrictor substances. FVR may have a small reproducibility advantage. Non‐experimental stimuli can cause significant and misleading changes in measured responses if unilateral measurements are used; it is therefore recommended that responses to intra‐arterial infusions should be measured using bilateral forearm plethysmography with the results expressed as FBF ratios.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2125.1998.00656.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 110

Metadata

Authors
Petrie, J. R., Ueda, S., Morris, A. D., Murray, L. S., Elliott, H. L., & Connell, J. M. C.
Venue
British Journal of Clinical Pharmacology
Publisher
Wiley
Published
1998-02
Volume
45
Issue
2
Pages
131-139
ISSN
  • 0306-5251 (ISSN-L)
  • 1365-2125
OpenAlex
W2141018820
Cited by
110
References
1
FWCI
18.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: How reproducible is bilateral forearm plethysmography? https://app.cochat.ai/papers/10.1046/j.1365-2125.1998.00656.x
The paper
Petrie, J. R., Ueda, S., Morris, A. D., Murray, L. S., Elliott, H. L., & Connell, J. M. C. (1998). How reproducible is bilateral forearm plethysmography? British Journal of Clinical Pharmacology. https://doi.org/10.1046/j.1365-2125.1998.00656.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.