Comparison of the effects of clonidine and yohimbine on pupillary diameter at different illumination levels
Open accessThe DOI matches its Crossref record.
Abstract
Aims To evaluate the pupillary effects of single doses of the α 2‐adrenoceptor agonist clonidine and the α 2‐adrenoceptor antagonist yohimbine under several illumination conditions. Methods Sixteen healthy male volunteers received clonidine 0.2 mg, yohimbine 22 mg, clonidine 0.2 mg + yohimbine 22 mg in a double‐blind placebo‐controlled, cross‐over study. 2 h post drug ingestion pupil diameter was recorded in darkness, and at luminance levels of 6 Cd m−2, 91 Cd m−2 and 360 Cd m−2. The effects of the active treatments on pupil diameter were also expressed as the differences from the placebo condition (‘placebo‐corrected’ data; mean [95% CI]). Results Clonidine had little effect on pupil diameter in darkness; however, it caused a significant, light‐dependent, miosis when the eye was illuminated. On the other hand yohimbine increased pupil size; this increase was significant at 91 and 360 Cd m−2. There were no significant differences between the effects of the combined treatment (clonidine 0.2 mg + yohimbine 22 mg) and the effect of placebo. Conclusions The pupillary effects of clonidine and yohimbine are likely to reflect the interaction of these drugs with inhibitory α 2‐adrenoceptors located on central noradrenergic neurones, which in turn would lead to a decrease and an increase, respectively, in sympathetic outflow to the iris. The light dependence of the pupillary effects of these drugs, however, suggests that the parasympathetic light reflex pathway is also involved, which is known to be under inhibitory control from the central noradrenergic neurones. Modulation of parasympathetic outflow seems to play an important role since both drugs had relatively little effect on pupil diameter in darkness when sympathetic activity predominates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The locus coeruleus and noradrenergic modulation of cognition
Sara, S. J. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2573 · Cited by 1,848
Joshi, S., Li, Y., Kalwani, R. M., & Gold, J. I. (2016) · Neuron · doi:10.1016/j.neuron.2015.11.028 · Cited by 1,387
Pupil Size as a Window on Neural Substrates of Cognition
Joshi, S., & Gold, J. I. (2020) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2020.03.005 · Cited by 598
Pupillometry and P3 index the locus coeruleus-noradrenergic arousal function in humans
Murphy, P. R., Robertson, I. H., Balsters, J. H., & O'connell, R. G. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2011.01226.x · Cited by 519
Samuels, E., & Szabadi, E. (2008) · Current Neuropharmacology · doi:10.2174/157015908785777193 · Cited by 454
Self-citation
Metadata
- Authors
- Phillips, M. A., Szabadi, E., & Bradshaw, C. M.
- Venue
- British Journal of Clinical Pharmacology
- Publisher
- Wiley
- Published
- 2000-07
- Volume
- 50
- Issue
- 1
- Pages
- 65-68
- ISSN
- 0306-5251 (ISSN-L)
- 1365-2125
- OpenAlex
- W1506809873
- Cited by
- 48
- References
- 0
- FWCI
- 0.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of the effects of clonidine and yohimbine on pupillary diameter at different illumination levels. https://app.cochat.ai/papers/10.1046/j.1365-2125.2000.00225.x
- The paper
- Phillips, M. A., Szabadi, E., & Bradshaw, C. M. (2000). Comparison of the effects of clonidine and yohimbine on pupillary diameter at different illumination levels. British Journal of Clinical Pharmacology. https://doi.org/10.1046/j.1365-2125.2000.00225.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.