Microdialysis methodology for the measurement of dermal interstitial fluid in humans
The DOI matches its Crossref record.
Abstract
In this study we aimed to validate the microdialysis technique for metabolic measurements in the dermal interstitial fluid. The abdominal and forearm skin was used for microdialysis in 15 healthy normal weight volunteers. The depth of the microdialysis catheter was assessed by ultrasound measurement. Structural impairment and blood flow were judged from biopsies and from laser Doppler measurements taken adjacent to the catheters. Dermal interstitial lactate and pyruvate concentrations were measured, under steady state fasting conditions, after equilibrium calibration of each catheter in situ. The dermal interstitial glucose concentration was estimated by means of the retrodialysis calibration method, which has previously not been evaluated for skin microdialysis. The mean catheter depth (+/- standard deviation) was 0.8 +/- 0.3 mm. Small areas of localized bleeding, but no inflammatory reaction, was found surrounding the catheters. The perfusion in the microdialysis region was slightly increased (15-25%). The lactate/pyruvate ratio (12 +/- 0.7) showed non-ischaemic values. The dermal interstitial lactate concentration was significantly higher (1171 +/- 228 mumol/l) than the plasma lactate (781 +/- 180 mumol/l), indicating an ongoing nonoxidative glucose metabolism. Retrodialysis calibration correctly estimated the dermal glucose level to be similar to that in plasma, which may indicate the usefulness of this calibration method for microdialysis studies of endogenous substrates in the dermal interstitial fluid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid
Wang, Z., Luan, J., Seth, A., Liu, L., You, M., Gupta, P., Rathi, P., Wang, Y., Cao, S., Jiang, Q., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00672-y · Cited by 386
Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Samant, P. P., & Prausnitz, M. R. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1716772115 · Cited by 363
In Vivo Methods for the Assessment of Topical Drug Bioavailability
Herkenne, C., Alberti, I., Naik, A., Kalia, Y. N., Mathy, F.-X., Préat, V., & Guy, R. H. (2008) · Pharmaceutical Research · doi:10.1007/s11095-007-9429-7 · Cited by 260
Extraction and biomolecular analysis of dermal interstitial fluid collected with hollow microneedles
Miller, P. R., Taylor, R. M., Tran, B. Q., Boyd, G., Glaros, T., Chavez, V. H., Krishnakumar, R., Sinha, A., Poorey, K., Williams, K. P., et al. (2018) · Communications Biology · doi:10.1038/s42003-018-0170-z · Cited by 258
Lymphatic transport of high-density lipoproteins and chylomicrons
Randolph, G. J., & Miller, N. E. (2014) · Journal of Clinical Investigation · doi:10.1172/jci71610 · Cited by 233
“Although subcutaneous implantation of microdialysis probes provides valuable information on movement of small molecules between plasma and interstitial fluid in humans, the molecular size cut-off of the probes is too low for recovery of lipoproteins (10, 11).”
Metadata
- Authors
- KROGSTAD, A. L., JANSSON, P.-A., GISSLÉN, P., & LÖNNROTH, P.
- Venue
- British Journal of Dermatology
- Publisher
- Oxford University Press (OUP)
- Published
- 1996-06
- Volume
- 134
- Issue
- 6
- Pages
- 1005-1012
- ISSN
- 0007-0963 (ISSN-L)
- OpenAlex
- W2042414592
- Cited by
- 98
- References
- 0
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microdialysis methodology for the measurement of dermal interstitial fluid in humans. https://app.cochat.ai/papers/10.1046/j.1365-2133.1996.d01-893.x
- The paper
- KROGSTAD, A. L., JANSSON, P.-A., GISSLÉN, P., & LÖNNROTH, P. (1996). Microdialysis methodology for the measurement of dermal interstitial fluid in humans. British Journal of Dermatology. https://doi.org/10.1046/j.1365-2133.1996.d01-893.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.