CoChat

Overnight urinary free cortisol determination: A screening test for the diagnosis of Cushing's syndrome

Corcuff, Jean‐Benoît, Tabarin, Antoine, Rashedi, Michel, Duclos, Martine, Roger, Patrick, Ducassou, Dominique · 1998 · Clinical Endocrinology
Cited by 44

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The collection of urine over 24 h to measure free cortisol (UFC) is used to diagnose Cushing's syndrome. However, a complete collection of urine is not easy to achieve and the sampling is frequently inaccurate, so a 24 h collection for the determination of UFC excretion is used as a confirmatory rather than a screening test for Cushing's syndrome. Our objective was to evaluate a more convenient urine collection for screening patients suspected of Cushing's syndrome. DESIGN: We have studied the possibility of using night‐time (from 2000 h to 0800 h) UFC excretion as a screening test for Cushing's syndrome (‘overnight UFC’). PATIENTS: Thirty patients with proven Cushing's syndrome were studied before treatment (21 cases of Cushing's disease, two cases of ectopic ACTH secretion, seven of adrenal adenoma). The results were compared to those from 150 control obese subjects. MEASUREMENTS: Overnight UFC, and creatininuria (UC), were evaluated at least once in the patients and in all subjects. The 24 h‐UFC and UC were determined at least once in the patients and in 56 control subjects. RESULTS: The overnight UFC/UC ratio clearly separated all but one patient of the two groups: 194 ± 386 vs 5.7 ± 3.4 nmol/μmol (P < 0.0005) (ranges 16.2–2024 vs 0.6–17.4, Cushing's syndrome vs controls, respectively). The only patient with Cushing's syndrome who had an overnight UFC/UC ratio that overlapped with that of controls suffered from renal failure. The 24 h UFC/UC ratio of the patients differed from the ratio of controls: 184 ± 365 vs 8.4 ± 4.1 nmol/μmol (P < 0.0005) (ranges 14–1639 vs 1.5–21.2, respectively). Four patients with Cushing's syndrome had 24 h UFC/UC ratios lower than the upper control ratio. CONCLUSION: The overnight urinary sampling is a simple procedure compared to the 24 h urine collection performed in out‐patients. For a sensitivity set at 100%, the specificities were 97% for the overnight UFC/UC ratio and 87% for the 24 h‐UFC/UC ratio. This therefore appears to provide a good screening method for Cushing's syndrome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2265.1998.00401.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 44

Metadata

Authors
Corcuff, J., Tabarin, A., Rashedi, M., Duclos, M., Roger, P., & Ducassou, D.
Venue
Clinical Endocrinology
Publisher
Wiley
Published
1998-04
Volume
48
Issue
4
Pages
503-508
ISSN
  • 0300-0664 (ISSN-L)
  • 1365-2265
OpenAlex
W2146162564
Cited by
44
References
2
FWCI
2.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Overnight urinary free cortisol determination: A screening test for the diagnosis of Cushing's syndrome. https://app.cochat.ai/papers/10.1046/j.1365-2265.1998.00401.x
The paper
Corcuff, J., Tabarin, A., Rashedi, M., Duclos, M., Roger, P., & Ducassou, D. (1998). Overnight urinary free cortisol determination: A screening test for the diagnosis of Cushing's syndrome. Clinical Endocrinology. https://doi.org/10.1046/j.1365-2265.1998.00401.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.