The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
3D microscopy of transparent objects using third‐harmonic generation
Abstract
It is demonstrated that third‐harmonic generation (THG) near interfaces in the refractive index or the third‐order nonlinear susceptibility (χ(3)) permits three‐dimensional imaging of transparent objects. The nonlinear dependence of THG on the excitation power provides inherent optical sectioning. At the same time, the nonresonant nature of THG, in combination with the near‐IR excitation wavelengths used (1–2 μm), render this technique potentially (biologically) nondamaging and nonbleaching. A specific property of THG imaging is its sensitivity to — and potential use for imaging of — the relative orientation of interfaces with respect to the axis of propagation of the excitation radiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Nonlinear scanning laser microscopy by third harmonic generation
Barad, Y., Eisenberg, H., Horowitz, M., & Silberberg, Y. (1997) · Applied Physics Letters · doi:10.1063/1.118442 · Cited by 607
Optical Third Harmonic Generation in Gases by a Focused Laser Beam
Ward, J. F., & New, G. H. C. (1969) · Physical Review · doi:10.1103/physrev.185.57 · Cited by 462
Optical third-harmonic generation at interfaces
Tsang, T. Y. F. (1995) · Physical Review A · doi:10.1103/physreva.52.4116 · Cited by 250
Nonlinear optical microscopic examination of structure in polycrystalline ZnSe
Hellwarth, R., & Christensen, P. (1974) · Optics Communications · doi:10.1016/0030-4018(74)90024-8 · Cited by 174
Dispersion pre‐compensation of 15 femtosecond optical pulses for high‐numerical‐aperture objectives
Müller, Squier, Wolleschensky, et al. (1998) · Journal of Microscopy · doi:10.1046/j.1365-2818.1998.00357.x · Cited by 103
Self-citationTwo-photon excitation in laser scanning fluorescence microscopy
Strickler, J. H., & Webb, W. W. (1991) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.47787 · Cited by 74
Cited by
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Three-Dimensional Vibrational Imaging by Coherent Anti-Stokes Raman Scattering
Zumbusch, A., Holtom, G. R., & Xie, X. S. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.4142 · Cited by 1,626
In vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505
Second harmonic generation microscopy for quantitative analysis of collagen fibrillar structure
Chen, X., Nadiarynkh, O., Plotnikov, S., & Campagnola, P. J. (2012) · Nature Protocols · doi:10.1038/nprot.2012.009 · Cited by 985
Interpreting Second-Harmonic Generation Images of Collagen I Fibrils
Williams, R. M., Zipfel, W. R., & Webb, W. W. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.047308 · Cited by 840
Metadata
- Authors
- Müller, Squier, Wilson, & Brakenhoff
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1998-09
- Volume
- 191
- Issue
- 3
- Pages
- 266-274
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2141324595
- Cited by
- 308
- References
- 7
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D microscopy of transparent objects using third‐harmonic generation. https://app.cochat.ai/papers/10.1046/j.1365-2818.1998.00399.x
- The paper
- Müller, Squier, Wilson, & Brakenhoff. (1998). 3D microscopy of transparent objects using third‐harmonic generation. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.1998.00399.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.