Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 308

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

3D microscopy of transparent objects using third‐harmonic generation

Müller, Squier, Wilson, Brakenhoff · 1998 · Journal of Microscopy

Abstract

It is demonstrated that third‐harmonic generation (THG) near interfaces in the refractive index or the third‐order nonlinear susceptibility (χ(3)) permits three‐dimensional imaging of transparent objects. The nonlinear dependence of THG on the excitation power provides inherent optical sectioning. At the same time, the nonresonant nature of THG, in combination with the near‐IR excitation wavelengths used (1–2 μm), render this technique potentially (biologically) nondamaging and nonbleaching. A specific property of THG imaging is its sensitivity to — and potential use for imaging of — the relative orientation of interfaces with respect to the axis of propagation of the excitation radiation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2818.1998.00399.x

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 308

Metadata

Authors
Müller, Squier, Wilson, & Brakenhoff
Venue
Journal of Microscopy
Publisher
Wiley
Published
1998-09
Volume
191
Issue
3
Pages
266-274
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W2141324595
Cited by
308
References
7
FWCI
10.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 3D microscopy of transparent objects using third‐harmonic generation. https://app.cochat.ai/papers/10.1046/j.1365-2818.1998.00399.x
The paper
Müller, Squier, Wilson, & Brakenhoff. (1998). 3D microscopy of transparent objects using third‐harmonic generation. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.1998.00399.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.