3D microscopy of transparent objects using third‐harmonic generation
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
It is demonstrated that third‐harmonic generation (THG) near interfaces in the refractive index or the third‐order nonlinear susceptibility (χ(3)) permits three‐dimensional imaging of transparent objects. The nonlinear dependence of THG on the excitation power provides inherent optical sectioning. At the same time, the nonresonant nature of THG, in combination with the near‐IR excitation wavelengths used (1–2 μm), render this technique potentially (biologically) nondamaging and nonbleaching. A specific property of THG imaging is its sensitivity to — and potential use for imaging of — the relative orientation of interfaces with respect to the axis of propagation of the excitation radiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Nonlinear scanning laser microscopy by third harmonic generation
Barad, Y., Eisenberg, H., Horowitz, M., & Silberberg, Y. (1997) · Applied Physics Letters · doi:10.1063/1.118442 · Cited by 607
Optical Third Harmonic Generation in Gases by a Focused Laser Beam
Ward, J. F., & New, G. H. C. (1969) · Physical Review · doi:10.1103/physrev.185.57 · Cited by 462
Optical third-harmonic generation at interfaces
Tsang, T. Y. F. (1995) · Physical Review A · doi:10.1103/physreva.52.4116 · Cited by 250
Nonlinear optical microscopic examination of structure in polycrystalline ZnSe
Hellwarth, R., & Christensen, P. (1974) · Optics Communications · doi:10.1016/0030-4018(74)90024-8 · Cited by 174
Dispersion pre‐compensation of 15 femtosecond optical pulses for high‐numerical‐aperture objectives
Müller, Squier, Wolleschensky, Simon, & Brakenhoff (1998) · Journal of Microscopy · doi:10.1046/j.1365-2818.1998.00357.x · Cited by 114
Self-citationTwo-photon excitation in laser scanning fluorescence microscopy
Strickler, J. H., & Webb, W. W. (1991) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.47787 · Cited by 90
Cited by
Nonlinear magic: multiphoton microscopy in the biosciences
Zipfel, W. R., Williams, R. M., & Webb, W. W. (2003) · Nature Biotechnology · doi:10.1038/nbt899 · Cited by 3,893
Three-Dimensional Vibrational Imaging by Coherent Anti-Stokes Raman Scattering
Zumbusch, A., Holtom, G. R., & Xie, X. S. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.4142 · Cited by 1,626
In vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505
Second harmonic generation microscopy for quantitative analysis of collagen fibrillar structure
Chen, X., Nadiarynkh, O., Plotnikov, S., & Campagnola, P. J. (2012) · Nature Protocols · doi:10.1038/nprot.2012.009 · Cited by 985
Interpreting Second-Harmonic Generation Images of Collagen I Fibrils
Williams, R. M., Zipfel, W. R., & Webb, W. W. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.047308 · Cited by 840
Single-pulse coherently controlled nonlinear Raman spectroscopy and microscopy
Dudovich, N., Oron, D., & Silberberg, Y. (2002) · Nature · doi:10.1038/nature00933 · Cited by 730
Deep tissue multiphoton microscopy using longer wavelength excitation
Kobat, D., Durst, M. E., Nishimura, N., Wong, A. W., Schaffer, C. B., & Xu, C. (2009) · Optics Express · doi:10.1364/oe.17.013354 · Cited by 574
Scanningless depth-resolved microscopy
Oron, D., Tal, E., & Silberberg, Y. (2005) · Optics Express · doi:10.1364/opex.13.001468 · Cited by 449
Theoretical and experimental characterization of coherent anti-Stokes Raman scattering microscopy
Cheng, J.-X., Volkmer, A., & Xie, X. S. (2002) · Journal of the Optical Society of America B · doi:10.1364/josab.19.001363 · Cited by 377
Laser-Scanning Coherent Anti-Stokes Raman Scattering Microscopy and Applications to Cell Biology
Cheng, J.-X., Jia, Y. K., Zheng, G., & Xie, X. S. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75186-2 · Cited by 371
Multiphoton microscopy in biological research
Williams, R. M., Zipfel, W. R., & Webb, W. W. (2001) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(00)00241-6 · Cited by 370
Membrane imaging by second-harmonic generation microscopy
Moreaux, L., Sandre, O., & Mertz, J. (2000) · Journal of the Optical Society of America B · doi:10.1364/josab.17.001685 · Cited by 345
Two-photon fluorescence excitation and related techniques in biological microscopy
Diaspro, A., Chirico, G., & Collini, M. (2005) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583505004129 · Cited by 318
Wave-Equation Description of Nonlinear Optical Interactions
Boyd, R. W. (2008) · Nonlinear Optics · doi:10.1016/b978-0-12-369470-6.00002-2 · Cited by 304
Volkmer, A., Book, L. D., & Xie, X. S. (2002) · Applied Physics Letters · doi:10.1063/1.1456262 · Cited by 292
Volkmer, A. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/5/r01 · Cited by 244
Third harmonic generation microscopy of cells and tissue organization
Weigelin, B., Bakker, G.-J., & Friedl, P. (2016) · Journal of Cell Science · doi:10.1242/jcs.152272 · Cited by 239
“THG signal strength and origin further depend on the orientation of the interface within the focal volume, with an optimal THGsignal generated byan interface orientation that is parallel to the excitation beam (Cheng and Xie, 2002;Müller et al., 1998) (Fig.”
BackgroundInfluentialHigh resolution nonlinear microscopy: A review of sources and methods for achieving optimal imaging
Squier, J., & Müller, M. (2001) · Review of Scientific Instruments · doi:10.1063/1.1379598 · Cited by 224
Coherent Scattering in Multi-Harmonic Light Microscopy
Moreaux, L., Sandre, O., Charpak, S., Blanchard-Desce, M., & Mertz, J. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76129-2 · Cited by 222
“…a different context, 3HG has also been reported to be a viable technique for the imaging of endogenous species without causing photobleaching or saturation, as normally occasioned by fluorescence (Muller et al., 1998; Yelin and Silberberg, 1999) and requires no interface-induced symmetry breaking.”
BackgroundTissue optical immersion clearing
Genina, E. A., Bashkatov, A. N., & Tuchin, V. V. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.50 · Cited by 208
Farrar, M. J., Wise, F. W., Fetcho, J. R., & Schaffer, C. B. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.01.031 · Cited by 193
Higher harmonic generation microscopy for developmental biology
Sun, C.-K., Chu, S.-W., Chen, S.-Y., Tsai, T.-H., Liu, T.-M., Lin, C.-Y., & Tsai, H.-J. (2004) · Journal of Structural Biology · doi:10.1016/j.jsb.2003.10.017 · Cited by 192
Label-free live brain imaging and targeted patching with third-harmonic generation microscopy
Witte, S., Negrean, A., Lodder, J. C., de Kock, C. P. J., Testa Silva, G., Mansvelder, H. D., & Louise Groot, M. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1018743108 · Cited by 186
“The hemoglobin in red blood cells is known to be a major source of THG signal when using 1,200–1,300 nm excitation light (15), through near-resonant excitation of the Soret band of the heme cofactor, which has a high nonlinear excitation cross-section due to its porphyrin structure (29).”
BackgroundMulti-photon excitation microscopy
Diaspro, A., Bianchini, P., Vicidomini, G., Faretta, M., Ramoino, P., & Usai, C. (2006) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-5-36 · Cited by 185
Infrared multiphoton microscopy: subcellular-resolved deep tissue imaging
Andresen, V., Alexander, S., Heupel, W.-M., Hirschberg, M., Hoffman, R. M., & Friedl, P. (2009) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2009.02.008 · Cited by 179
“Its nonresonant nature in combination with NIR excitation wavelengths (1–2 mm) renders this technique very interesting for imaging biological and nonbiological specimens [31].”
BackgroundChu, S.-W., Chen, S.-Y., Chern, G.-W., Tsai, T.-H., Chen, Y.-C., Lin, B.-L., & Sun, C.-K. (2004) · Biophysical Journal · doi:10.1529/biophysj.103.034595 · Cited by 176
“…other hand, due to the optical dispersion property in biological tissues, THG was proven to be generated from regions with optical inhomogeneity and was applied to image general cellular and subcellular structures (Barad et al., 1997; Müller et al., 1998; Chu et al., 2001; Sun et al., 2003a,b).”
BackgroundCarriles, R., Schafer, D. N., Sheetz, K. E., Field, J. J., Cisek, R., Barzda, V., Sylvester, A. W., & Squier, J. A. (2009) · Review of Scientific Instruments · doi:10.1063/1.3184828 · Cited by 170
Green's function formulation for third-harmonic generation microscopy
Cheng, J.-X., & Xie, X. S. (2002) · Journal of the Optical Society of America B · doi:10.1364/josab.19.001604 · Cited by 165
Zheng, Z., Li, D., Liu, Z., Peng, H., Sung, H. H. Y., Kwok, R. T. K., Williams, I. D., Lam, J. W. Y., Qian, J., & Tang, B. Z. (2019) · Advanced Materials · doi:10.1002/adma.201904799 · Cited by 161
Albert, O., Sherman, L., Mourou, G., Norris, T. B., & Vdovin, G. (2000) · Optics Letters · doi:10.1364/ol.25.000052 · Cited by 158
Metadata
- Authors
- Müller, Squier, Wilson, & Brakenhoff
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 1998-09
- Volume
- 191
- Issue
- 3
- Pages
- 266-274
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2141324595
- Cited by
- 308
- References
- 7
- FWCI
- 10.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.