CoChat

Cylindrical diameters method for calibrating section thickness in serial electron microscopy

Open access
Fiala, J. C., Harris, K. M. · 2001 · Journal of Microscopy
Cited by 143

The DOI matches its Crossref record.

Abstract

An estimate of section thickness is required for measuring structures in serial section microscopy. Mean section thickness is estimated reliably by averaging the ratios of the diameters of cylindrical objects, such as mitochondria, to the number of sections they span. This cylindrical diameters method improves the accuracy of section thickness as inferred from the colour of sections floating in water. The cylindrical diameters method gives the same answer as that obtained by the minimal folds method. It is preferable because it can be done in a series that has no folds that can distort and obscure the objects that are being measured.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1046/j.1365-2818.2001.00926.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 143

Metadata

Authors
Fiala, J. C., & Harris, K. M.
Venue
Journal of Microscopy
Publisher
Wiley
Published
2001-06
Volume
202
Issue
3
Pages
468-472
ISSN
  • 0022-2720 (ISSN-L)
  • 1365-2818
OpenAlex
W1967094886
Cited by
143
References
0
FWCI
4.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cylindrical diameters method for calibrating section thickness in serial electron microscopy. https://app.cochat.ai/papers/10.1046/j.1365-2818.2001.00926.x
The paper
Fiala, J. C., & Harris, K. M. (2001). Cylindrical diameters method for calibrating section thickness in serial electron microscopy. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.2001.00926.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.