The DOI matches its Crossref record.
Two‐photon fluorescence absorption and emission spectra of dyes relevant for cell imaging
Abstract
Summary: Two‐photon absorption and emission spectra for fluorophores relevant in cell imaging were measured using a 45 fs Ti:sapphire laser, a continuously tuneable optical parametric amplifier for the excitation range 580–1150 nm and an optical multichannel analyser. The measurements included DNA stains, fluorescent dyes coupled to antibodies as well as organelle trackers, e.g. Alexa and Bodipy dyes, Cy2, Cy3, DAPI, Hoechst 33342, propidium iodide, FITC and rhodamine. In accordance with the two‐photon excitation theory, the majority of the investigated fluorochromes did not reveal significant discrepancies between the two‐photon and the one‐photon emission spectra. However, a blue‐shift of the absorption maxima ranging from a few nanometres up to considerably differing courses of the spectrum was found for most fluorochromes. The potential of non‐linear laser scanning fluorescence microscopy is demonstrated here by visualizing multiple intracellular structures in living cells. Combined with 3D reconstruction techniques, this approach gives a deeper insight into the spatial relationships of subcellular organelles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Intracellular localisation of human HIF-1α hydroxylases:implications for oxygen sensing
Metzen, E., Berchner-Pfannschmidt, U., Stengel, P., Marxsen, J. H., Stolze, I., Klinger, M., Huang, W. Q., Wotzlaw, C., Hellwig-Bürgel, T., Jelkmann, W., et al. (2003) · Journal of Cell Science · doi:10.1242/jcs.00318 · Cited by 432
Self-citationTwo-photon excitation microscopy for the study of living cells and tissues
Benninger, R. K. P., & Piston, D. W. (2013) · Current Protocols in Cell Biology · doi:10.1002/0471143030.cb0411s59 · Cited by 311
Two-Photon Absorption: An Open Door to the NIR-II Biological Window?
Shaw, P. A., Forsyth, E., Haseeb, F., Yang, S., Bradley, M., & Klausen, M. (2022) · Frontiers in Chemistry · doi:10.3389/fchem.2022.921354 · Cited by 75
Metadata
- Authors
- Bestvater, F., Spiess, E., Stobrawa, G., Hacker, M., Feurer, T., Porwol, T., Berchner‐Pfannschmidt, U., Wotzlaw, C., & Acker, H.
- Venue
- Journal of Microscopy
- Publisher
- Wiley
- Published
- 2002-11
- Volume
- 208
- Issue
- 2
- Pages
- 108-115
- ISSN
- 0022-2720 (ISSN-L)
- 1365-2818
- OpenAlex
- W2161932153
- Cited by
- 215
- References
- 0
- FWCI
- 5.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two‐photon fluorescence absorption and emission spectra of dyes relevant for cell imaging. https://app.cochat.ai/papers/10.1046/j.1365-2818.2002.01074.x
- The paper
- Bestvater, F., Spiess, E., Stobrawa, G., Hacker, M., Feurer, T., Porwol, T., Berchner‐Pfannschmidt, U., Wotzlaw, C., & Acker, H. (2002). Two‐photon fluorescence absorption and emission spectra of dyes relevant for cell imaging. Journal of Microscopy. https://doi.org/10.1046/j.1365-2818.2002.01074.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.