Correlations among Epworth Sleepiness Scale scores, multiple sleep latency tests and psychological symptoms
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
The aim of this study was to identify factors other than objective sleep tendency associated with scores on the Epworth Sleepiness Scale (ESS). There were 225 subjects, of whom 40% had obstructive sleep apnoea (OSA), 16% had simple snoring, and 4.9% had snoring with sleep disruption (upper airway resistance syndrome); 9.3% had narcolepsy and 7.5% had hypersomnolence without REM sleep abnormalities; 12% had chronic fatigue syndrome; 7.5% had periodic limb movement disorder and 3% had diurnal rhythm disorders. ESS, the results of overnight polysomnography and multiple sleep latency test (MSLT) and SCL‐90 as a measure of psychological symptoms were recorded. The ESS score and the mean sleep latency (MSL) were correlated (Spearman ??=−0.30, P<0.0001). The MSL was correlated with total sleep time (TST) and with sleep efficiency but not with apnoea/hypopnoea index. There was no association between the MSL and any aspect of SCL‐90 scores, except a borderline significant association with the somatisation subscale. The ESS was correlated with TST but not with sleep efficiency or apnoea/hypopnoea index. The ESS was correlated with all subscales of the SCL‐90 except psychoticism. An ESS≥10 had poor sensitivity and specificity as a predictor of MSL <10 min or MSL <5 min. We conclude that the MSLT and the ESS are not interchangeable. The ESS was influenced by psychological factors by which the MSL was not affected. The ESS cannot be used to demonstrate or exclude sleepiness as it is measured by MSLT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale
Johns, M. W. (1991) · Sleep · doi:10.1093/sleep/14.6.540 · Cited by 17,364 · cited 7×
“Johns (1991), however, observed a significant correlation between ESS andthem to be abnormally sleepy to report ESS within the normal range.”
BackgroundMethodInfluentialThe american college of rheumatology 1990 criteria for the classification of fibromyalgia
Wolfe, F., Smythe, H. A., Yunus, M. B., Bennett, R. M., Bombardier, C., Goldenberg, D. L., Tugwell, P., Campbell, S. M., Abeles, M., Clark, P., et al. (1990) · Arthritis & Rheumatism · doi:10.1002/art.1780330203 · Cited by 9,563 · cited 1×
“The ESS was correlated with theAssociation (Wolfe et al. 1990). global severity index of the SCL-90 and with all the subscalesPatients arrived at the sleep laboratory following an evening except psychoticism.meal without alcohol or caffeine.”
MethodThe Chronic Fatigue Syndrome: A Comprehensive Approach to Its Definition and Study
Fukuda, K., Straus, S. E., Hickie, I., Sharpe, M. C., Dobbins, J. G., Komaroff, A., & and International Chronic Fatigue Syndrome Study Group. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-121-12-199412150-00009 · Cited by 4,969
Daytime Sleepiness, Snoring, and Obstructive Sleep Apnea
Johns, M. W. (1993) · Chest · doi:10.1378/chest.103.1.30 · Cited by 1,119 · cited 3×
“…of our results with those of others.from deliberate misrepresentation is important when decisions about a patient’s fitness to engage in hazardous activities have The correlation between MSL and ESS reported here (0.30) was lower than that reported by Johns (1993) (0.42) but closeto be made.”
BackgroundResultInfluentialSleepiness in Different Situations Measured by the Epworth Sleepiness Scale
Johns, M. W. (1994) · Sleep · doi:10.1093/sleep/17.8.703 · Cited by 734 · cited 2×
“(MSL) measured in the MSLT is only moderate (Johns 1994).”
BackgroundResultRelationship between sleepiness and general health status
Briones, B., Adams, N., Strauss, M., Rosenberg, C., Whalen, C., Carskadon, M., Roebuck, T., Winters, M., & Redline, S. (1996) · SLEEP · doi:10.1093/sleep/19.7.583 · Cited by 253 · cited 2×
“It was common for patients whose partners estimated to that reported by Briones et al. (1996) (0.27).”
BackgroundMethodInfluentialA Comparison of Clinical Assessment and Home Oximetry in the Diagnosis of Obstructive Sleep Apnea
Gyulay, S., Olson, L. G., Hensley, M. J., King, M. T., Allen, K. M., & Saunders, N. A. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/147.1.50 · Cited by 209 · cited 1×
“The instrumentation and Correlations between ESS scores and the other variables forscoring methods used in the laboratory have been described in the whole sample and for patients with MSL less than 5 mindetail elsewhere (Gyulay et al. 1993).”
MethodSelf-citationEstimation of the Probability of Disturbed Breathing during Sleep before a Sleep Study
Crocker, B. D., Olson, L. G., Saunders, N. A., Hensley, M. J., McKeon, J. L., Allen, K. M., & Gyulay, S. G. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/142.1.14 · Cited by 202 · cited 1×
“Both in clinic (Crocker et al. 1990) and in population samples (Olson et al. 1995; Bliwise and King 1996),The ESS may be especially inappropriate as a surrogate for the MSLT in epidemiological studies.”
Self-citationDaytime Sleepiness in Insomnia: Behavioral, Biological and Subjective Indices
Lichstein, K. L., Wilson, N. M., Noe, S. L., Aguillard, R. N., & Bellur, S. N. (1994) · Sleep · doi:10.1093/sleep/17.8.693 · Cited by 117 · cited 2×
“Because the possibility exists, however, we have avoided as far as possible statistical analyses that requirethe MSL and some other subjective measures of sleepiness (Lichstein et al. 1994). the assumption that the ESS is an interval scale.”
BackgroundA community study of snoring and sleep-disordered breathing. Symptoms.
Olson, L. G., King, M. T., Hensley, M. J., & Saunders, N. A. (1995) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.152.2.7633730 · Cited by 65
Self-citationJohnson, L. C., Freeman, C. R., Spinweber, C. L., & Gomez, S. A. (1991) · Psychophysiology · doi:10.1111/j.1469-8986.1991.tb03388.x · Cited by 52
Cited by
Buysse, D. J., Hall, M. L., Strollo, P. J., Kamarck, T. W., Owens, J., Lee, L., Reis, S. E., & Matthews, K. A. (2008) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27351 · Cited by 858
Buysse, D. J., Yu, L., Moul, D. E., Germain, A., Stover, A., Dodds, N. E., Johnston, K. L., Shablesky-Cade, M. A., & Pilkonis, P. A. (2010) · Sleep · doi:10.1093/sleep/33.6.781 · Cited by 850
Johns, M. W. (2000) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2000.00177.x · Cited by 824
Distinguishing sleepiness and fatigue: focus on definition and measurement
Shen, J., Barbera, J., & Shapiro, C. M. (2006) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2005.05.004 · Cited by 687
Evaluation of the measurement properties of the Epworth sleepiness scale: A systematic review
Kendzerska, T. B., Smith, P. M., Brignardello-Petersen, R., Leung, R. S., & Tomlinson, G. A. (2014) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2013.08.002 · Cited by 334
Metadata
- Authors
- OLSON, L., COLE, M., & AMBROGETTI, A.
- Venue
- Journal of Sleep Research
- Publisher
- Wiley
- Published
- 1998-12
- Volume
- 7
- Issue
- 4
- Pages
- 248-253
- ISSN
- 0962-1105 (ISSN-L)
- 1365-2869
- OpenAlex
- W2050379247
- Cited by
- 193
- References
- 12
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.